Effect of Noise-Optimized Monoenergetic Postprocessing on Diagnostic Accuracy for Detecting Incidental Pulmonary Embolism in Portal-Venous Phase Dual-Energy Computed Tomography

被引:44
|
作者
Weiss, Jakob [1 ]
Notohamiprodjo, Mike [1 ]
Bongers, Malte [1 ]
Schabel, Christoph [1 ]
Mangold, Stefanie [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Eberhard Karls Univ Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
computed tomography; dual-energy CT; dual-source CT; noise-optimized monoenergetic imaging; pulmonary CT angiography; pulmonary embolism; CT ANGIOGRAPHY; RISK-FACTORS; CANCER-PATIENTS; IMAGE-QUALITY; CONTRAST; RECONSTRUCTION; SETTINGS; STRATIFICATION; THROMBOSIS; DATASETS;
D O I
10.1097/RLI.0000000000000319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to evaluate the diagnostic accuracy of virtual monoenergetic images (MEI+) at low kiloelectronvolt levels for the detection of incidental pulmonary embolism (PE) in oncological follow-up portal-venous phase dual-energy (DE-CTpv) staging. Materials and Methods: Twenty-six patients with incidental PE in DE-CTpv staging, which was confirmed by computed tomography pulmonary angiography (CTPA), were included in this study. In addition, 26 matched control patientswho were negative for PE in both DE-CTpv and CTPA were included. All examinations were performed on a third-generation DE-CT system in single-energy (CTPA) and dual-energymode (DE-CTpv). Subsequently, 2 series of MEI+ data sets were reconstructed at 40 and 55 keV from the DE-CTpv data and compared with CTPA and the linearly blended CTpv images. Diagnostic accuracy and diagnostic confidence were calculated and compared for MEI+ reconstructions and for CTpv images regarding the detection of PE with CTPA as standard of reference. Results: In 3 patients, PE was only detectable in CTPA and in the 40-kV and 55-kVMEI+ reconstructions but not in CTpv images. Diagnostic accuracy increased significantly for both MEI+ series (40 keV; area under the curve [AUC], 0.928; 95% confidence interval [CI], 0.879-0.978; 55 keV; AUC, 0.960; 95% CI, 0.922-0.998) as compared with CTpv (AUC, 0.814; 95% CI, 0.741-0.887; P = 0.004). Diagnostic confidence was rated highest in CTPA (median, 5; range, 3-5) followed by 55-keV MEI+ and 40-keV MEI+ (median, 5; range, 2-5 and median, 5; range, 2-5, respectively) and was lowest for CTpv (median, 4; range, 1-5), with significant differences to CTPA and MEI+ reconstructions (P = 0.001). Conclusions: Monoenergetic image reconstructions fromDE-CT data sets at low kiloelectronvolt levels improve diagnostic accuracy for the detection of incidental PE in oncological follow-up DE-CTpv staging, with the highest subjective diagnostic confidence in MEI+ at 55 keV.
引用
收藏
页码:142 / 147
页数:6
相关论文
共 25 条
  • [1] Optimal Kiloelectron Volt for Noise-optimized Virtual Monoenergetic Images of Dual-Energy Pediatric Abdominopelvic Computed Tomography: Preliminary Results
    Kim, Taek Min
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In-One
    Park, Ji Eun
    Shin, Su-mi
    Pak, Seong Yong
    Krauss, Bernhard
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (02) : 283 - 294
  • [2] Noise-optimized monoenergetic post-processing improves visualization of incidental pulmonary embolism in cancer patients undergoing single-pass dual-energy computed tomography
    Weiss, Jakob
    Notohamiprodjo, Mike
    Bongers, Malte
    Schabel, Christoph
    Mangold, Stefanie
    Nikolaou, Konstantin
    Bamberg, Fabian
    Othman, Ahmed E.
    RADIOLOGIA MEDICA, 2017, 122 (04): : 280 - 287
  • [3] Dual-energy computed tomography in patients with cutaneous malignant melanoma: Comparison of noise-optimized and traditional virtual monoenergetic imaging
    Martin, Simon S.
    Wichmann, Julian L.
    Weyer, Hendrik
    Albrecht, Moritz H.
    D'Angelo, Tommaso
    Leithner, Doris
    Lenga, Lukas
    Booz, Christian
    Scholtz, Jan-Erik
    Bodelle, Boris
    Vogl, Thomas J.
    Hammerstingl, Renate
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 95 : 1 - 8
  • [4] Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma
    Martin, Simon S.
    Wichmann, Julian L.
    Pfeifer, Sophia
    Leithner, Doris
    Lenga, Lukas
    Reynolds, Michael A.
    D'Angelo, Tommaso
    Hammerstingl, Renate
    Gruber-Rouh, Tatjana
    Vogl, Thomas J.
    Albrecht, Moritz H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 97 : 1 - 7
  • [5] Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors
    Martin, Simon S.
    Pfeifer, Sophia
    Wichmann, Julian L.
    Albrecht, Moritz H.
    Leithner, Doris
    Lenga, Lukas
    Scholtz, Jan-Erik
    Vogl, Thomas J.
    Bodelle, Boris
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 718 - 726
  • [6] A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions
    De Cecco, Carlo N.
    Caruso, Damiano
    Schoepf, U. Joseph
    De Santis, Domenico
    Muscogiuri, Giuseppe
    Albrecht, Moritz H.
    Meinel, Felix G.
    Wichmann, Julian L.
    Burchett, Philip F.
    Varga-Szemes, Akos
    Sheafor, Douglas H.
    Hardie, Andrew D.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3393 - 3404
  • [7] Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen
    Martin, Simon S.
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Leithner, Doris
    D'Angelo, Tommaso
    Weyer, Hendrik
    Booz, Christian
    Lenga, Lukas
    Vogl, Thomas J.
    Albrecht, Moritz H.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (09) : 1257 - 1266
  • [8] Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors
    Simon S. Martin
    Sophia Pfeifer
    Julian L. Wichmann
    Moritz H. Albrecht
    Doris Leithner
    Lukas Lenga
    Jan-Erik Scholtz
    Thomas J. Vogl
    Boris Bodelle
    Abdominal Radiology, 2017, 42 : 718 - 726
  • [9] Virtual Monoenergetic Imaging and Iodine Perfusion Maps Improve Diagnostic Accuracy of Dual-Energy Computed Tomography Pulmonary Angiography With Suboptimal Contrast Attenuation
    Leithner, Doris
    Wichmann, Julian L.
    Vogl, Thomas J.
    Trommer, Jesko
    Martin, Simon S.
    Scholtz, Jan-Erik
    Bodelle, Boris
    De Cecco, Carlo N.
    Duguay, Taylor
    Nance, John W., Jr.
    Schoepf, U. Joseph
    Albrecht, Moritz H.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (11) : 659 - 665
  • [10] Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography
    Foti, Giovanni
    Silva, Ronaldo
    Faccioli, Niccolo
    Fighera, Alessandro
    Menghini, Rossella
    Campagnola, Arianna
    Carbognin, Giovanni
    EUROPEAN RADIOLOGY, 2021, 31 (04) : 1923 - 1931