Correction method of surface effects in infrared laser transillumination CT imaging

被引:2
|
作者
Sasaki, Y [1 ]
Inage, H [1 ]
Emori, R [1 ]
Goto, M [1 ]
Takahashi, R [1 ]
Tanosaki, S [1 ]
Yuasa, T [1 ]
Taniguchi, H [1 ]
Devaraj, B [1 ]
Akatsuka, T [1 ]
机构
[1] Yamagata Univ, Fac Engn, Yonezawa, Yamagata 9928510, Japan
来源
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2004年 / 5368卷
关键词
laser computed tomography; laser; image reconstruction; optical heterodyne detection; optical fiber; coherent detection imaging (CDI);
D O I
10.1117/12.534495
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A reconstruction method for transillumination laser CT using optical heterodyne detection is proposed. Laser CT does not obey the Radon transform due to surface effects, which occur as results of refractive index mismatch and roughness of surface, and bring about annulus artifact and impair quantitative accuracy of a reconstructed image. Optical attenuation with surface effects is described using a model function with respect to an incident angle. This reconstruction produces a least squares problem incorporating the surface effect, which is solved via the conjugate gradient method. The method is applied to data from a acrylic physical phantom containing Intralipid-10% solution in various concentrations for demonstrating the effectiveness of the proposed method in terms of morphological and quantitative information. The CDI method is proved to have an excellent quantitative accuracy.
引用
收藏
页码:939 / 949
页数:11
相关论文
共 50 条
  • [41] Effects of laser treatments on surface roughness of zirconium oxide ceramics
    Goknil Ergun Kunt
    Ibrahim Duran
    BMC Oral Health, 18
  • [42] Effects of laser surface modification of nimonic with aluminum on oxidation behavior
    Rodriguez, GP
    García, I
    Damborenea, J
    OXIDATION OF METALS, 2002, 58 (1-2): : 235 - 248
  • [43] Laser Surface Treatment of Stainless Steel and Environmental Dust Effects
    Yilbas, B. S.
    Ali, H.
    Karatas, C.
    Al-Sharafi, A.
    Abu-Dheir, N.
    Al-Qahtani, H.
    Khaled, M.
    LASERS IN ENGINEERING, 2020, 45 (4-6) : 243 - 263
  • [44] Effects of laser treatments on surface roughness of zirconium oxide ceramics
    Kunt, Goknil Ergun
    Duran, Ibrahim
    BMC ORAL HEALTH, 2018, 18
  • [45] Artifacts correction method for fan-beam CT with projections asymmetrically truncated on both sides
    Yang, Min
    Han, Xu
    Wu, Xiaojun
    Zhao, Gang
    Wei, Dongtao
    Lang, Tian
    Zhang, Shunli
    NDT & E INTERNATIONAL, 2017, 87 : 24 - 30
  • [46] A Method for 3D Motion Correction of Nuclear Medicine Planar Imaging Data
    Caramelo, F. J.
    Faria, D.
    Ferreira, N. C.
    Lima, J. J. P.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 2276 - 2279
  • [47] Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters
    Manjappa, Rakesh
    Makki, Sharath S.
    Kumar, Rajesh
    Kanhirodan, Rajan
    MEDICAL PHYSICS, 2015, 42 (02) : 750 - 759
  • [48] Combined Infrared Thermal Imaging and Laser Heating for the Study of Materials Thermophysical and Processing Properties at High Temperatures
    Elhadj, Selim
    Matthews, Manyalibo J.
    Yang, Steven T.
    CRITICAL REVIEWS IN SOLID STATE AND MATERIALS SCIENCES, 2014, 39 (03) : 175 - 196
  • [49] Quantitative evaluation of beam-hardening artefact correction in dual-energy CT myocardial perfusion imaging
    Andreas M. Bucher
    Julian L. Wichmann
    U. Joseph Schoepf
    Christopher D. Wolla
    Christian Canstein
    Andrew D. McQuiston
    Aleksander W. Krazinski
    Carlo N. De Cecco
    Felix G. Meinel
    Thomas J. Vogl
    Lucas L. Geyer
    European Radiology, 2016, 26 : 3215 - 3222
  • [50] Quantitative evaluation of beam-hardening artefact correction in dual-energy CT myocardial perfusion imaging
    Bucher, Andreas M.
    Wichmann, Julian L.
    Schoepf, U. Joseph
    Wolla, Christopher D.
    Canstein, Christian
    McQuiston, Andrew D.
    Krazinski, Aleksander W.
    De Cecco, Carlo N.
    Meinel, Felix G.
    Vogl, Thomas J.
    Geyer, Lucas L.
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3215 - 3222