Clinical Comparison of the Effectiveness of Single-file Reciprocating Systems and Rotary Systems for Removal of Endotoxins and Cultivable Bacteria from Primarily Infected Root Canals

被引:39
作者
Martinho, Frederico C. [1 ]
Gomes, Ana P. M. [1 ]
Fernandes, Aleteia M. M. [1 ]
Ferreira, Nadia S. [1 ]
Endo, Marcos S. [1 ]
Freitas, Lilian E. [1 ]
Camoes, Izabel C. G. [2 ]
机构
[1] State Univ Sao Paulo, UNESP, Sao Jose dos Campos Dent Sch, Endodont Div,Dept Restorat Dent, BR-12245000 Sao Paulo, Brazil
[2] Univ Fed Fluminense, Dept Restorat Dent, Endodont Div, Niteroi, RJ, Brazil
基金
巴西圣保罗研究基金会;
关键词
Bacteria; disinfection; endodontics; endotoxin; root canal; SELF-ADJUSTING FILE; 2.5-PERCENT SODIUM-HYPOCHLORITE; CYCLIC FATIGUE RESISTANCE; APICALLY EXTRUDED DEBRIS; NICKEL-TITANIUM; CHEMOMECHANICAL PREPARATION; INSTRUMENTATION TECHNIQUES; PROTAPER; WAVEONE; EFFICACY;
D O I
10.1016/j.joen.2013.12.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This clinical study was conducted to compare the effectiveness of single-file reciprocating systems and rotary systems in removing endotoxins and cultivable bacteria from primarily infected root canals. Methods: Forty-eight primarily infected root canals were selected and randomly divided into 4 groups: WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) (n = 12); Reciproc (VDW, Munich, Germany) (n = 12), ProTaper (Dentsply Maillefer) (n = 12), and Mtwo (VDW) (n = 12). Samples were collected before and after chemomechanical preparation. The irrigation was performed by using 2.5% sodium hypochlorite. A chromogenic limulus amebocyte lysate assay test was used to quantify endotoxins. Culture techniques were used to determine bacterial colony-forming unit counts. Results: In the baseline samples (ie, samples collected before chemomechanical preparation), endotoxins and cultivable bacteria were recovered from 100% of the root canal samples. No differences were found in the median percentage values of endotoxin reduction achieved with reciprocating systems (ie, WaveOne [95.15%] and Reciproc [96.21%]) and with rotary systems (ie, ProTaper [97.98%] and Mtwo [96.34%]) (P < .05). Both single-file reciprocating systems (ie, WaveOne [99.45%] and Reciproc [99.93%]) and rotary systems (ProTaper [99.85%] and Mtwo [99.41%]) were effective in reducing the cultivable bacteria (all P < .05). Moreover, the culture analysis revealed no differences in bacterial load reduction (P > .05). Conclusions: Both single-file reciprocating systems (ie, WaveOne and Reciproc instruments) and rotary systems (ie, ProTaper and Mtwo instruments) showed similar effectiveness in reducing endotoxins and cultivable bacteria from primarily infected root canals, but they were not able to eliminate them from all root canals analyzed.
引用
收藏
页码:625 / 629
页数:5
相关论文
共 36 条
[1]   Evaluation of Cyclic Flexural Fatigue of M-Wire Nickel-Titanium Rotary Instruments [J].
Al-Hadlaq, Solaiman M. S. ;
AlJarbou, Fahad A. ;
AlThumairy, Riyadh I. .
JOURNAL OF ENDODONTICS, 2010, 36 (02) :305-307
[2]   Quantitative molecular and culture analyses of bacterial elimination in oval-shaped root canals by a single-file instrumentation technique [J].
Alves, F. R. F. ;
Rocas, I. N. ;
Almeida, B. M. ;
Neves, M. A. S. ;
Zoffoli, J. ;
Siqueira, J. F., Jr. .
INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (09) :871-877
[3]   Differences in Cyclic Fatigue Resistance at Apical and Coronal Levels of Reciproc and Wave One New Files [J].
Arias, Ana ;
Perez-Higueras, Juan J. ;
de la Macorra, Jose C. .
JOURNAL OF ENDODONTICS, 2012, 38 (09) :1244-1248
[4]  
Barbizam JVB, 2002, J ENDODONT, V28, P365
[5]   Canal Shaping with WaveOne Primary Reciprocating Files and ProTaper System: A Comparative Study [J].
Berutti, Elio ;
Chiandussi, Giorgio ;
Paolino, Davide Salvatore ;
Scotti, Nicola ;
Cantatore, Giuseppe ;
Castellucci, Arnaldo ;
Pasqualini, Damiano .
JOURNAL OF ENDODONTICS, 2012, 38 (04) :505-509
[6]   Apically Extruded Debris with Reciprocating Single-File and Full-sequence Rotary Instrumentation Systems [J].
Buerklein, Sebastian ;
Schaefer, Edgar .
JOURNAL OF ENDODONTICS, 2012, 38 (06) :850-852
[7]   In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper, WaveOne, and Twisted Files [J].
Castello-Escriva, Ricardo ;
Alegre-Domingo, Teresa ;
Faus-Matoses, Vicente ;
Roman-Richon, Sophie ;
Faus-Llacer, Vicente J. .
JOURNAL OF ENDODONTICS, 2012, 38 (11) :1521-1524
[8]   Comparison of Two Rotary Systems in Root Canal Preparation Regarding Disinfection [J].
de Lima Machado, Manoel Eduardo ;
Bichels Sapia, Luiz Antonio ;
Cai, Silvana ;
Rosa Martins, Guilherme Henrique ;
Nabeshima, Cleber Keiti .
JOURNAL OF ENDODONTICS, 2010, 36 (07) :1238-1240
[9]   Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement [J].
De-Deus, Gustavo ;
Brandao, Maria Claudia ;
Barino, Bianca ;
Di Giorgi, Karina ;
Sergio Fidel, Rivail Antonio ;
Luna, Aderval Severino .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (03) :390-394
[10]   In Vitro Canal and Isthmus Debris Removal of the Self-Adjusting File, K3, and WaveOne Files in the Mesial Root of Human Mandibular Molars [J].
Dietrich, Matthew A. ;
Kirkpatrick, Timothy C. ;
Yaccino, John M. .
JOURNAL OF ENDODONTICS, 2012, 38 (08) :1140-1144