The Development of an Instrumented Wheelchair Propulsion Testing and Training Device

被引:7
作者
Klaesner, Joseph [1 ]
Morgan, Kerri A. [2 ]
Gray, David B. [2 ]
机构
[1] Washington Univ, Program Phys Therapy, St Louis, MO 63108 USA
[2] Washington Univ, Program Occupat Therapy, St Louis, MO 63108 USA
关键词
manual wheelchair; propulsion; wheelchair technologies; wheelchair training; PUSHRIM BIOMECHANICS; USERS; CLINICIAN; PATTERNS; MOBILITY; POSITION; KINETICS; WRIST;
D O I
10.1080/10400435.2013.792020
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Researchers have used several types of testing devices and training surfaces to examine wheelchair propulsion. Testing and training wheelchair users on the actual surface of interest, such as tile floors or ramps, is ideal but difficult. Devices such as treadmills, dynamometers, and ergometers allow for researchers and clinicians to observe wheelchair users in a controlled space. However, these devices often do not have the ability to realistically simulate the environment. This methodological article describes the instrumentation, development and function of a wheelchair dynamometer system, the WheelMill System (WMS), a uniquely adjustable roller system for wheelchairs. Three participants wheeled on the WMS, over a tile surface and up two different graded slopes with the SmartWheel to compare speed and forces. The WMS reasonably simulated propulsion over a tile floor, though the participants' speed was slightly faster on tile, and the peak forces for each propulsion stroke varied more on tile than on the WMS. For the slopes, the speed oscillated over a greater range and was slower, and the measured peak forces were higher than the values measured on the WMS. The WMS may have several applications, though additional studies on a greater and more diverse population are needed.
引用
收藏
页码:24 / 32
页数:9
相关论文
共 30 条
[1]  
[Anonymous], 2000, Report No. 14
[2]   Wheelchair skills training for community-based manual wheelchair users: A randomized controlled trial [J].
Best, KL ;
Kirby, RL ;
Smith, C ;
MacLeod, DA .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (12) :2316-2323
[3]  
Boninger ML, 2000, ARCH PHYS MED REHAB, V81, P608, DOI 10.1053/mr.2000.1455
[4]   Propulsion patterns and pushrim biomechanics in manual wheelchair propulsion [J].
Boninger, ML ;
Souza, AL ;
Cooper, RA ;
Fitzgerald, SG ;
Koontz, AM ;
Fay, BT .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (05) :718-723
[5]   Pushrim biomechanics and injury prevention in spinal cord injury: Recommendations based on CULP-SCI investigations [J].
Boninger, ML ;
Koontz, AM ;
Sisto, SA ;
Dyson-Hudson, TA ;
Chang, M ;
Price, R ;
Cooper, RA .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2005, 42 (03) :9-19
[6]   Wheelchair Pushrim kinetics: Body weight and median nerve function [J].
Boninger, ML ;
Cooper, RA ;
Baldwin, MA ;
Shimada, SD ;
Koontz, A .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (08) :910-915
[7]   Wheelchair skills training program for clinicians: A randomized controlled trial with occupational therapy students [J].
Coolen, AL ;
Kirby, L ;
Landry, J ;
MacPhee, AH ;
Dupuis, D ;
Smith, C ;
Best, KL ;
MacKenzie, DE ;
MacLeod, DA .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (07) :1160-1167
[8]  
Cooper R.A., 1998, Wheelchair selection and configuration
[9]   Preliminary outcomes of the SmartWheel Users' Group database: a proposed framework for clinicians to objectively evaluate manual wheelchair propulsion [J].
Cowan, Rachel E. ;
Boninger, Michael L. ;
Sawatzky, Bonita J. ;
Mazoyer, Brian D. ;
Cooper, Rory A. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2008, 89 (02) :260-268
[10]   Consequence of feedback-based learning of an effective hand rim wheelchair force production on mechanical efficiency [J].
de Groot, S ;
Veeger, HEJ ;
Hollander, AP ;
van der Woude, LHV .
CLINICAL BIOMECHANICS, 2002, 17 (03) :219-226