Automated sampling system for the analysis of amino acids using microfluidic capillary electrophoresis

被引:15
|
作者
Xu, Zhang-Run [1 ]
Lan, Yue [1 ]
Fan, Xiao-Feng [1 ]
Li, Qi [1 ]
机构
[1] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
关键词
Automated sampling; Microfluidics; Capillary electrophoresis; Liquid-core waveguide; Laser-induced fluorescence; Amino acids; FLOW-INJECTION; SEPARATION; INTERFACE; CHIPS; CE;
D O I
10.1016/j.talanta.2008.11.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improved automated continuous sample introduction system for microfluidic capillary electrophoresis (CE) is described. A sample plate was designed into gear-shaped and was fixed onto the shaft of a step motor. Twenty slotted reservoirs for containing samples and working electrolytes were fabricated on the "gear tooth" of the plate. A single 7.5-cm long Teflon AF-coated silica capillary serves as separation channel, sampling probe, as well as liquid-core waveguide (LCW) for light transmission. Platinum layer deposited on the capillary tip serves as the electrode. Automated continuous sample introduction was achieved by scanning the capillary tip through the slots of reservoirs. The sample was introduced into capillary and separated immediately in the capillary with only about 2-nL gross sample consumption. The laser-induced fluorescence (LIF) method with LCW technique was used for detecting fluorescein isothiocyanate (FITC)-labeled amino acids. With electric-field strength of 320V/cm for injection and separation, and 1.0-s sample injection time, a mixture of FITC-labeled arginine and leucine was separated with a throughput of 60/h and a carryover of 2.7%. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
  • [41] A Novel Capillary Electrophoresis-Chemiluminescence System for Separation and Detection of Amino Acids
    Yin Dong-Guang
    Wu Ming-Hong
    Xie Chun-Juan
    Zhang Li
    Liu Bing-Hu
    Zhou Xiao-Zhou
    Wang Peng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (01) : 152 - 156
  • [42] Key conditions in capillary electrophoresis of amino acids with indirect ultraviolet detection
    Wang, ZX
    Chen, Y
    Guo, Q
    CHINESE CHEMICAL LETTERS, 2000, 11 (09) : 803 - 806
  • [43] High-speed separation and detection of amino acids in laver using a short capillary electrophoresis system
    Wang, Wei
    Ma, Lihong
    Yao, Fenzeng
    Lin, Xiuli
    Xu, Kaixuan
    ELECTROPHORESIS, 2015, 36 (02) : 335 - 340
  • [44] SEPARATION AND DETECTION OF AMINO-ACIDS AND THEIR ENANTIOMERS BY CAPILLARY ELECTROPHORESIS - A REVIEW
    ISSAQ, HJ
    CHAN, KC
    ELECTROPHORESIS, 1995, 16 (04) : 467 - 480
  • [45] Chiral separation of aromatic amino acids by capillary electrophoresis
    Bjergegaard, C
    Hansen, LP
    Moller, P
    Sorensen, H
    Sorensen, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (01) : 137 - 146
  • [46] Chiral separation of benzothiazole derivatives of amino acids using capillary zone electrophoresis
    Novakova, Zuzana
    Pejchal, Vladimir
    Fischer, Jan
    Cesla, Petr
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (03) : 798 - 803
  • [47] Capillary electrophoresis on unmodified genetically coded amino acids
    A. G. Mosina
    I. O. Mel’nikov
    I. V. Nazimov
    Yu. M. Glubokov
    Journal of Analytical Chemistry, 2009, 64 : 637 - 641
  • [48] Enantiomeric separation of amino acids by capillary electrophoresis with α-cyclodextrin
    Dzygiel, P
    Wieczorek, P
    Jönsson, JÅ
    JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (02) : 414 - 418
  • [49] Capillary electrophoresis with NDA derivatization and electrochemical detection for the analysis of cellular amino acids
    Swanek, FD
    Anderson, BB
    Ewing, AG
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1998, 10 (02) : 185 - 192
  • [50] On-site sampling of inorganic contamination on the metal surface and analysis with capillary electrophoresis
    Xu, Ning
    Lin, Haifeng
    Uchiyama, Katsumi
    Lin, Jin-Ming
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (08) : 1593 - 1599