Ion chromatographic behaviour and determination of perbromates

被引:4
|
作者
Megoulas, NC [1 ]
Koupparis, MA [1 ]
机构
[1] Univ Athens, Dept Chem, Analyt Chem Lab, Athens 15771, Greece
关键词
perbromate; phenate; ion chromatography; conductimetric detection;
D O I
10.1016/j.aca.2004.01.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion chromatographic behaviour of perbromates in aqueous solutions was studied, using ion suppressed conductimetric detection (Dionex DX-100 ion chromatograph with ASRS-I suppressor). Various eluents (sodium hydroxide, carbonate and phenate solutions) were examined using the AS-144 mm x 250 mm anion-exchange column and an optimization study concerning pH and total eluate concentration of mobile phase was carried out. Phenate buffer (20.0 mM, pH 11.0) at 1.18 ml/min flow rate, gave the best results. Calibration curve was linear in the range of 1.5-200ppm. with a limit of detection of 0.46ppm and R.S.D. 1.8% (100 ppm standard). Perbromates were separated with good resolution from potentially interfering anions (bromides, bromates, iodides, perchlorates). Selectivity coefficients were determined for perbromates. perchlorates and iodides, from linear plots of retention volume versus the reciprocal of eluent concentration. The new method was used to monitor the perbromate reactions with lactic acid, iodide and citric acid in the absence and presence of Fe(II) acting as an inducer. Furthermore. it was confirmed the inability of various common strong oxidative media to oxidize bromate to perbromate. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [1] ION CHROMATOGRAPHIC DETERMINATION OF PLATINUM IN BIOTIC MATERIALS
    JERONO, U
    ALT, F
    MESSERSCHMIDT, J
    TOLG, G
    MIKROCHIMICA ACTA, 1992, 108 (3-6) : 221 - 226
  • [2] Ion chromatographic determination of gaseous toxic compounds
    Blanchard, E
    Bourdin, M
    Tua, M
    Cassan, J
    ANALUSIS, 1996, 24 (04) : 123 - 126
  • [3] Ion chromatographic determination of anions in environmental samples
    Khwaja, HA
    Khan, AR
    Qureshi, S
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1999, 75 (03) : 285 - 297
  • [4] Ion chromatographic determination of metals in biocompatibility testing
    Buldini, PL
    Mevoli, A
    Sharma, JL
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 50 (02): : 131 - 137
  • [5] ION CHROMATOGRAPHIC DETERMINATION OF PERCHLORATE IN CATTLE URINE
    BATJOENS, P
    DEBRABANDER, HF
    TKINDT, L
    ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) : 335 - 340
  • [6] Ion chromatographic determination of chloride in mustard sauces
    Agüero, EL
    Bosch, NB
    Vázquez, CB
    Ruiz, BL
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (11) : 4682 - 4685
  • [7] Ion chromatographic determination of total acidity in aqueous solutions
    Hu, WZ
    Hasebe, K
    Tanaka, K
    ANALYTICAL SCIENCES, 2002, 18 (12) : 1383 - 1385
  • [8] Ion Chromatographic Determination of Cations and Anions in Tap Water
    Liu, Dongwu
    Chen, Zhiwei
    Xu, Lei
    Zhang, Zhengjie
    Ju, Baoyu
    Cheng, Wenchao
    ADVANCED RESEARCH ON AUTOMATION, COMMUNICATION, ARCHITECTONICS AND MATERIALS, PTS 1 AND 2, 2011, 225-226 (1-2): : 128 - +
  • [9] Ion Chromatographic Determination of Nitrite and Nitrate in Tobacco Leaf
    Wu, Li
    Song, Ze-Min
    Chen, Yong-An
    Zhu, Hong-Ying
    Li, Zhang-Hai
    Gao, Yun
    Yang, Jun
    Hung, Yi-De
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (17) : 9520 - 9522
  • [10] Ion chromatographic method for the determination of orotic acid in urine
    Destanoglu, Orhan
    Zeydanli, Damla
    Cansever, Mehmet Serif
    Yilmaz, Gulcin Gumus
    ANALYTICAL BIOCHEMISTRY, 2018, 563 : 9 - 14