The syringe potentiometer: a low-cost device for pneumotachograph calibration

被引:4
作者
Cross, Troy J. [1 ,2 ]
Kelley, Eli F. [1 ]
Hardy, Tim A. [3 ]
Isautier, Jennifer M. J. [1 ]
Johnson, Bruce D. [1 ]
机构
[1] Mayo Clin, Dept Cardiovasc Dis, Rochester, MN 55902 USA
[2] Griffith Univ, Menzies Hlth Inst Queensland, Brisbane, Qld, Australia
[3] Univ Leeds, Sch Biomed Sci, Leeds, W Yorkshire, England
关键词
calibration; pneumotachograph; potentiometer; respiratory airflow; syringe; ACCURACY;
D O I
10.1152/japplphysiol.00150.2019
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this report was to 1) detail the construction of a low-cost device that provides a "reference" flow waveform for pneumotachograph (PNT) calibration, i.e., the "syringe potentiometer" (SP), and to compare the 2) accuracy and 3) practical performance of "calibration curves" obtained with the SP device to other more established methods of PNT calibration, i.e., the weighted averaging (WA) and polynomial least-squares (PolyLS) methods. Volume and flow waveforms obtained via the SP device were validated against a motion capture system and were deemed accurate surrogates of actual syringe volume and flows. The SP device was used to construct a calibration curve of a PNT by dividing the flow waveform of the SP by the analog output of the PNT amplifier. A total of 187 inspiratory and 187 expiratory strokes were collected. When the entire data set of expiratory strokes was used, the SP, WA, and PolyLS methods together demonstrated acceptable volume and flow errors as per American Thoracic Society/European Respiratory Society recommendations (less than +/- 3.5% and less than +/- 5.0% errors, respectively). The "practical" performance of each method was assessed with a nested subsampling procedure, whereby volume and flow errors were evaluated as the number of strokes was increased (in blocks of 5 strokes). To this end, the SP method demonstrated practical performance superior to that of the WA and PolyLS approaches, whereby acceptable volume and flow errors were achieved after only 5 calibration strokes; the WA and PolyLS methods required 15 and 20 strokes, respectively, to achieve the same level of volume and flow accuracy. NEW & NOTEWORTHY This report describes the construction and validation of a low-cost device for the purposes of pneumotachograph (PNT) calibration: the "syringe potentiometer" (SP). Calibration of a PNT with the SP device yielded acceptable volume and flow errors (<3.5% and 5%, respectively) across a wide range of flows (<0.5 to 15 L/s). The SP device offered superior "practical performance" over other established PNT calibration methods, whereby acceptable volume and flow errors were achieved after only five calibration strokes.
引用
收藏
页码:1150 / 1162
页数:13
相关论文
共 50 条
  • [41] DEVELOPMENT, CALIBRATION AND TESTING OF A LOW-COST SMALL LYSIMETER FOR MONITORING EVAPORATION AND TRANSPIRATION
    Bello, Zaid A.
    Van Rensburg, Leon D.
    IRRIGATION AND DRAINAGE, 2017, 66 (02) : 263 - 272
  • [42] Image Correction and In Situ Spectral Calibration for Low-Cost, Smartphone Hyperspectral Imaging
    Davies, Matthew
    Stuart, Mary B.
    Hobbs, Matthew J.
    McGonigle, Andrew J. S.
    Willmott, Jon R.
    REMOTE SENSING, 2022, 14 (05)
  • [43] Calibration of low-cost NO2 sensors in an urban air quality network
    van Zoest, Vera
    Osei, Frank B.
    Stein, Alfred
    Hoek, Gerard
    ATMOSPHERIC ENVIRONMENT, 2019, 210 : 66 - 75
  • [44] New Calibration Method for Implementing Machine Learning in Low-Cost Sensor Applications
    Murrell, Niko
    Bradley, Ryan
    Bajaj, Nikhil
    Whitney, Julie
    Chiu, George T-C
    IEEE SENSORS LETTERS, 2020, 4 (02)
  • [45] LOW-COST BATHYMETRY PROTOTYPE AND ADAPTED SONAR CALIBRATION FOR WATER RESERVOIR MEASUREMENT
    Marques, Ademir, Jr.
    Racolte, Graciela
    Sales, Vinicius Ferreira
    Braga, Luiz Fernando
    Veronez, Mauricio Roberto
    de Castro, Dalva Maria
    2022 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2022), 2022, : 6328 - 6331
  • [46] LOW-PROCESSING DATA ENRICHMENT AND CALIBRATION FOR PM2.5 LOW-COST SENSORS
    Stojanovi, Danka B.
    Kleut, Duska N.
    Davidovi, Milos D.
    De Vito, Saverio
    Jovasevi-Stojanovi, Milena, V
    Bartonova, Alena
    Lepioufle, Jean-Marie
    THERMAL SCIENCE, 2023, 27 (3B): : 2229 - 2240
  • [47] Low-Cost Phase Shifter and Calibration Solution for Multi-Channel Receiver
    Fei, Qinshun
    Yu, Ying
    Yin, Xiaoxing
    Yang, Liang
    Lu, Yiwen
    2016 IEEE INTERNATIONAL CONFERENCE ON UBIQUITOUS WIRELESS BROADBAND (ICUWB2016), 2016,
  • [48] Calibration Methods for Low-Cost Particulate Matter Sensors Considering Seasonal Variability
    Kang, Jiwoo
    Choi, Kanghyeok
    SENSORS, 2024, 24 (10)
  • [49] Calibration of digital camera integration accuracy for low-cost oblique aerial photogrammetry
    Liu, Likun
    Shao, Zhenfeng
    GEO-SPATIAL INFORMATION SCIENCE, 2015, 18 (2-3) : 90 - 96
  • [50] Evaluation of a New Smartphone Powered Low-cost Pulse Oximeter Device
    Nemomssa, Hundessa Daba
    Raj, Hakkins
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2022, 32 (04) : 841 - 848