Determination of Elemental Impurities in Iron-nickel-based Superalloys by Glow Discharge Mass Spectrometry

被引:8
作者
Hu, F. F. [1 ]
Wang, C. H. [1 ]
Li, J. D. [2 ]
Liu, P. Y. [2 ]
Liu, H. [1 ]
Zhang, L. [1 ]
机构
[1] Guobiao Beijing Testing & Certificat Co Ltd, Beijing 101407, Peoples R China
[2] China United Test & Certificat Co Ltd, Beijing 101407, Peoples R China
关键词
RELATIVE SENSITIVITY FACTORS;
D O I
10.46770/AS.2020.215
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A method for the determination of impurities in iron-nickel-based superalloys by high-resolution glow discharge mass spectrometry is described. The optimum discharge conditions were investigated to obtain stable discharge and good sensitivity. The interference was separated in high resolution mode of the instrument. The calibration relative sensitivity factors (RSF) for 12 elements were obtained with the matrix-matched certified reference material. IARM Ni909-18. The reference material was analyzed by using the calibration RSFs. The relative error of the measured value was within 16.4% compared with the certified value, and the relative standard deviation (RSD) was less than 7.0%. The 12 elements in the iron-nickel-based superalloy were determined using the calibration RSFs (quantitative analysis) and the standard RSFs (semi-quantitative analysis) in the instrument, including C, N, O and S. The results of the verification methods, such as inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), high frequency combustion infrared absorption and inert gas pulse infrared thermal conductivity, were closer to quantitative analysis results. The elements without certified values in the reference material were determined by using the standard RSFs. There was no significant difference between the results of GDMS and the verification by ICP-MS. The validation revealed that the proposed analytical approach achieves reliable results for the rapid determination of several impurities, such as metals as well as non-metals, even the gas elements C, N, O and S.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 29 条
  • [21] Quantitative Analysis of IMPURITIES in Gallium Metal Using RSF Calculated by Analyzing Aluminum Matrix CRMs Using Glow Discharge Mass Spectrometer
    Yang, J.
    Shin, H.
    Jung, S.
    Yoon, J.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2021, 36 (04): : 813 - 819
  • [22] Implementation of Nanoscale Secondary-Ion Mass Spectrometry Analyses: Application to Ni-Based Superalloys
    Almoric, Jean
    Durand, Malik
    Seret, Anthony
    Nicolay, Alexis
    Houel, Arnaud
    Berbezier, Isabelle
    Bozzolo, Nathalie
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2022, 219 (09):
  • [23] Silicon and indium as secondary cathodes for the analysis of solid alumina and sapphire by slow-flow direct-current glow discharge mass spectrometry
    Busam, Jochen
    Paudel, Gagan
    Di Sabatino, Marisa
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (01) : 172 - 177
  • [24] Evaluation of different strategies for quantitative depth profile analysis of Cu/NiCu layers and multilayers via pulsed glow discharge - Time of flight mass spectrometry
    Muniz, Rocio
    Lobo, Lara
    Nemeth, Katalin
    Peter, Laszlo
    Pereiro, Rosario
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 135 : 34 - 41
  • [25] A similar-matrix-matched calibration strategy by using microsecond pulsed glow discharge mass spectrometry in the application of purity analysis of high purity lanthanum oxide
    Zhan, Jianying
    Zhou, Tao
    Song, Dan
    Tang, Yichuan
    Cui, Yanjie
    Wu, Bing
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 164
  • [26] The relationship between relative sensitivity factors and ionization potential in dc glow discharge mass spectrometry using Ar 0.2 vol% H2 mixture
    Saito, M
    ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) : 129 - 134
  • [27] Application of 7N In as secondary cathode for the direct current-glow discharge mass spectrometry analysis of solid, fused high-purity quartz
    Busam, Jochen
    Stokkan, Gaute
    Muggerud, Astrid Marie F.
    Di Sabatino, Marisa
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (08):
  • [28] Determining Trace Rare-earth Oxides in High-purity Europium Oxide by Microsecond-pulsed and Continuous Direct-current Glow-discharge Mass Spectrometry
    Zhang, Jianying
    Zhou, Tao
    Cui, Yanjie
    Tang, Yichuan
    Wu, Bing
    ATOMIC SPECTROSCOPY, 2021, 42 (02) : 79 - 84
  • [29] Assignment of purity to primary metal calibrants using pin-cell VG 9000 glow discharge mass spectrometry: a primary method with direct traceability to the SI international system of units?
    Sturgeon, R. E.
    Methven, B.
    Willie, S. N.
    Grinberg, P.
    METROLOGIA, 2014, 51 (05) : 410 - 422