A fast and sensitive UHPLC-MS/ MS method for the determination of N-butylscopolamine in human plasma: application in a bioequivalence study

被引:0
|
作者
Suenaga, Eunice Mayumi [1 ]
Val, Ligia de Cassia [2 ]
Tominaga, Mineko [2 ]
Souza Filho, Jose Homero [3 ]
Soares, Gidel [4 ]
Vioto, Monalisa [4 ]
Nakaie, Clovis Ryuichi [1 ]
机构
[1] Univ Fed Sao Paulo, Escola Paulista Med, Dept Biofis, Nucleo Bioequivalencia & Ensaios Clin, Sao Paulo, SP, Brazil
[2] Associacao Paulista Desenvolvimento Med, Sao Paulo, SP, Brazil
[3] Univ Fed Pernambuco, Nucleo Desenvolvimento Farmaceut & Cosmet, Recife, PE, Brazil
[4] Secretaria Saude Estado Sao Paulo, Fundacao Remedio Popular, Sao Paulo, SP, Brazil
关键词
bioequivalence; human plasma; N-butylscopolamine; pharmacokinetic study; UHPLC-MS/; MS; HIGHLY VARIABLE DRUGS; HYOSCINE BUTYLBROMIDE; VALIDATION; URINE;
D O I
10.1002/bmc.3823
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed and validated a fast and sensitive ultra high-performance liquid chromatography with positive ion electrospray ionization tandem mass spectrometry method for determining N-butylscopolamine levels in human plasma using propranolol as an internal standard.The acquisition was set up in the multiple reaction monitoring mode with the transitions m/ z 360.3.138.0 for N-butylscopolamine and m/ z 260.2.116.1 for IS.This method uses a liquid-liquid extraction process with dichloromethane.The analyte and IS were chromatographed on a C18, 50x2.1 mm, 1.7 mu m column through isocratic elution with acetonitrile- 5mM ammonium acetate (adjusted to pH 3.0 with formic acid).The method was linear in the 1-1000 pg/ mL range for N-butylscopolamine and was selective, precise, accurate and robust.The validated method was successfully applied to perform a bioequivalence study of the reference (Buscopan r, from Boehringer Ingelheim) and the test sample coated-tablet formulations (from Foundation for Popular Remedy), both containing 10 mg of N-butylscopolamine bromide administered as a single dose.Using 58 healthy volunteers and accounting for the high intra-individual variability confirmed by statistical calculations (38%), the two formulations were considered bioequivalent because the rate and extent of absorption (within 80-125% interval), satisfying international requirements.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Simultaneous determination of epalrestat and puerarin in rat plasma by UHPLC-MS/MS: Application to their pharmacokinetic interaction study
    Sun, Hong
    Bo, Yunhai
    Zhang, Mingjie
    Wu, Xiao
    Zhou, Mingyang
    Zhao, Longshan
    Xiong, Zhili
    BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (04)
  • [42] Validated LC-MS-MS Method for the Determination of Gabapentin in Human Plasma: Application to a Bioequivalence Study
    Wattananat, Triporn
    Akarawut, Wiyada
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2009, 47 (10) : 868 - 871
  • [43] LC-MS/MS Method for Determination of Megestrol in Human Plasma and Its Application in Bioequivalence Study
    Li, Fan
    Zou, Xiao-juan
    Zheng, Heng
    Xiang, Yi
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2013, 33 (06) : 912 - 916
  • [44] Determination of sophoraflavanone G and kurarinone in rat plasma by UHPLC-MS/MS and its application to a pharmacokinetic study
    Yang, Zhixin
    Zhang, Wenjun
    Li, Xia
    Shan, Baisong
    Liu, Jiajia
    Deng, Weizhe
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (22) : 4344 - 4353
  • [45] Determination of DQ-798 in rat plasma by UHPLC-MS/MS and its application to a pharmacokinetic study
    Zhang, Zhi-Feng
    Chen, Li
    Ding, Li-Sheng
    Liu, Liang
    Zhou, Hua
    Luo, Pei
    Qing, Lin-Sen
    BIOCHEMICAL PHARMACOLOGY, 2017, 139 : 114 - 114
  • [46] LC-MS/MS method for determination of megestrol in human plasma and its application in bioequivalence study
    Fan Li
    Xiao-juan Zou
    Heng Zheng
    Yi Xiang
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2013, 33 : 912 - 916
  • [47] HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development
    Havlikova, Lucie
    Vlckova, Hana
    Solich, Petr
    Novakova, Lucie
    BIOANALYSIS, 2013, 5 (19) : 2345 - 2357
  • [48] A sensitive and specific method for measurement of multiple retinoids in human serum with UHPLC-MS/MS
    Arnold, Samuel L. M.
    Amory, John K.
    Walsh, Thomas J.
    Isoherranen, Nina
    JOURNAL OF LIPID RESEARCH, 2012, 53 (03) : 587 - 598
  • [49] Development of a UHPLC-MS/MS method for the determination of plasma histamine in various mammalian species
    Liu, Jia
    Wang, Lei
    Hu, Wenjuan
    Chen, Xiaoyan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 971 : 35 - 42
  • [50] A UHPLC-MS/MS Method for the Quantitation of Olmutinib in Rat Plasma
    Bao, Su-su
    Wen, Jian
    Liu, Teng-hui
    Zhang, Bo-wen
    Wang, Chen-chen
    Hu, Guo-xin
    ACTA CHROMATOGRAPHICA, 2019, 31 (02) : 105 - 108