A fast and sensitive UHPLC-MS/ MS method for the determination of N-butylscopolamine in human plasma: application in a bioequivalence study

被引:0
|
作者
Suenaga, Eunice Mayumi [1 ]
Val, Ligia de Cassia [2 ]
Tominaga, Mineko [2 ]
Souza Filho, Jose Homero [3 ]
Soares, Gidel [4 ]
Vioto, Monalisa [4 ]
Nakaie, Clovis Ryuichi [1 ]
机构
[1] Univ Fed Sao Paulo, Escola Paulista Med, Dept Biofis, Nucleo Bioequivalencia & Ensaios Clin, Sao Paulo, SP, Brazil
[2] Associacao Paulista Desenvolvimento Med, Sao Paulo, SP, Brazil
[3] Univ Fed Pernambuco, Nucleo Desenvolvimento Farmaceut & Cosmet, Recife, PE, Brazil
[4] Secretaria Saude Estado Sao Paulo, Fundacao Remedio Popular, Sao Paulo, SP, Brazil
关键词
bioequivalence; human plasma; N-butylscopolamine; pharmacokinetic study; UHPLC-MS/; MS; HIGHLY VARIABLE DRUGS; HYOSCINE BUTYLBROMIDE; VALIDATION; URINE;
D O I
10.1002/bmc.3823
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed and validated a fast and sensitive ultra high-performance liquid chromatography with positive ion electrospray ionization tandem mass spectrometry method for determining N-butylscopolamine levels in human plasma using propranolol as an internal standard.The acquisition was set up in the multiple reaction monitoring mode with the transitions m/ z 360.3.138.0 for N-butylscopolamine and m/ z 260.2.116.1 for IS.This method uses a liquid-liquid extraction process with dichloromethane.The analyte and IS were chromatographed on a C18, 50x2.1 mm, 1.7 mu m column through isocratic elution with acetonitrile- 5mM ammonium acetate (adjusted to pH 3.0 with formic acid).The method was linear in the 1-1000 pg/ mL range for N-butylscopolamine and was selective, precise, accurate and robust.The validated method was successfully applied to perform a bioequivalence study of the reference (Buscopan r, from Boehringer Ingelheim) and the test sample coated-tablet formulations (from Foundation for Popular Remedy), both containing 10 mg of N-butylscopolamine bromide administered as a single dose.Using 58 healthy volunteers and accounting for the high intra-individual variability confirmed by statistical calculations (38%), the two formulations were considered bioequivalent because the rate and extent of absorption (within 80-125% interval), satisfying international requirements.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] A UHPLC-MS/MS method for the simultaneous determination of vancomycin, norvancomycin, meropenem, and moxalactam in human plasma and its clinical application
    Huo, Jiping
    Guo, Yangyang
    Zhang, Bo
    Zhao, Zhigang
    Shi, Guangzhi
    Mei, Shenghui
    JOURNAL OF MASS SPECTROMETRY, 2023, 58 (06): : e4925
  • [32] UHPLC-MS/MS method to determine FP-208 in human plasma and its application to a pharmacokinetic study
    Wang, Huanhuan
    Wang, Teng
    Wang, Zhanqing
    Du, Zhenjian
    Zhao, Qian
    Jiang, Ji
    Hu, Pei
    BIOANALYSIS, 2020, 12 (06) : 367 - 378
  • [33] UHPLC-MS/MS method for determination of atorvastatin calcium in human plasma: Application to a pharmacokinetic study based on healthy volunteers with specific genotype
    Xia, Binbin
    Li, Yali
    Zhang, Yatong
    Xue, Ming
    Li, Xiaorong
    Xu, Pingxiang
    Xia, Tao
    Chen, Shicai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 160 : 428 - 435
  • [34] A Rapid and Sensitive LC–MS Method for Determination of Ezetimibe Concentration in Human Plasma: Application to a Bioequivalence Study
    Hossein Danafar
    Mehrdad Hamidi
    Chromatographia, 2013, 76 : 1667 - 1675
  • [35] Development and Validation of a Rapid and Sensitive LC-MS/MS Method for the Determination of Aripiprazole in Human Plasma: Application to a Bioequivalence Study
    Patel, D. S.
    Sharma, N.
    Patel, M. C.
    Patel, B. N.
    Shrivastav, P. S.
    Sanyal, M.
    ACTA CHROMATOGRAPHICA, 2014, 26 (02) : 203 - 227
  • [36] Development and validation of a selective and sensitive LC-MS/MS method for determination of cycloserine in human plasma: Application to bioequivalence study
    Patel, Dinesh S.
    Sharma, Naveen
    Patel, Mukesh C.
    Patel, Bhavin N.
    Shrivastav, Pranav S.
    Sanyal, Mallika
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2265 - 2273
  • [37] A More Rapid, Simple and Sensitive HPLC-MS/MS Method for Determination of Epinastine in Human Plasma and Application to a Bioequivalence Study
    Shi, Lei
    Chen, Xuwang
    Zhang, Yunyun
    Wei, Chunmin
    Geng, Chunmei
    Gao, Meimei
    Shaikh, Abdul Sami
    Wang, Benjie
    Guo, Ruichen
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (06): : 1314 - 1320
  • [38] Development of a UHPLC-MS/MS method for the determination of quercetin in milk and its application to a pharmacokinetic study
    Gbylik-Sikorska, Malgorzata
    Gajda, Anna
    Burmanczuk, Artur
    Grabowski, Tomasz
    Posyniak, Andrzej
    JOURNAL OF VETERINARY RESEARCH, 2019, 63 (01) : 87 - 91
  • [39] Estimation of minoxidil in human plasma using UHPLC-MS/MS and its application in pharmacokinetic study
    Basuri, P. Poorna
    Vijayakumar, R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1192
  • [40] Determination of lesinurad in rat plasma by a UHPLC-MS/MS assay
    Zhou, Xiao-Yang
    Yuan, Ling-Jing
    Chen, Zhe
    Tang, Peng-Fei
    Li, Xiang-Yu
    Hu, Guo-Xin
    Cai, Jian-Ping
    CHEMISTRY CENTRAL JOURNAL, 2017, 11 : 1 - 7