Saturated pool boiling from carbon nanotube coated surfaces at different orientations

被引:52
作者
Ho, J. Y. [1 ]
Leong, K. C. [1 ]
Yang, C. [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
Saturated pool boiling; Surface orientation; Carbon nanotube; Bare silicon; Critical heat flux; CRITICAL HEAT-FLUX; MICRO-PIN-FINS; ENHANCED SURFACES; SILICON CHIPS; NUCLEATE; GRAPHITE; HFE-7100; FC-72; SIZE; CHF;
D O I
10.1016/j.ijheatmasstransfer.2014.08.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experiments were conducted to investigate the effects of carbon nanotube (CNT) coated surfaces and the influence of surface orientations on saturated pool boiling heat transfer and critical heat flux (CHF). A 1 cm x 1 cm fully coated CNT surface and an interlaced patterned CNT surface of coating thickness 215 mu m were prepared. In FC-72 under atmospheric condition, bare silicon, fully coated CNT surface and interlaced patterned CNT surface were initially tested at constant surface orientation of 90 degrees to determine the effect of CNT coating. Further experiments were then carried out with bare silicon and fully coated CNT surface at 0 degrees, 30 degrees, 60 degrees, 120 degrees, 150 degrees and 180 degrees to examine and compare the effects of surface orientation. Results showed that at constant surface orientation of 90, both the fully coated CNT surface and the interlaced patterned CNT surface enhanced the average heat transfer coefficient by 42% as compared to the bare silicon despite the interlaced patterned CNT surface having only 70% CNT coating area. On the influence of surface orientation, results with the fully coated CNT surface showed that heat transfer performance decreases with increasing surface orientation whereas bare silicon exhibited improvement in heat transfer between 0 degrees and 90 degrees and deterioration in heat transfer between 90 degrees and 180 degrees. In addition, CNT coatings were also found to enhance CHF as the CHF of fully coated CNT surface consistently surpassed those of bare silicon for the same orientation. On the other hand, a similar trend on the dependence of CHF on orientation was observed, where CHF of bare silicon and fully coated CNT surface were seen to decrease with increasing surface orientation. The highest average heat transfer coefficient of 0.45 W/cm(2) K and highest CHF of 20.1 W/cm(2) were recorded for fully coated CNT surface at 0 degrees surface orientation. Lastly, for both bare silicon and fully coated CNT surface, Rohsenow's correlation was used to characterize the pool boiling curves and the models of Kutateladze and Zuber were used to develop the CHF correlations at different surface orientations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:893 / 904
页数:12
相关论文
共 32 条
[1]   Pool Boiling Experiments on a Nano-Structured Surface [J].
Ahn, Hee Seok ;
Sathyamurthi, Vijaykumar ;
Banerjee, Debjyoti .
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2009, 32 (01) :156-165
[2]   The effect of capillary wicking action of micro/nano structures on pool boiling critical heat flux [J].
Ahn, Ho Sean ;
Lee, Chan ;
Kim, Joonwon ;
Kim, Moo Hwan .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (1-3) :89-92
[3]  
Anderson T.M., 1985, T ASME, V111, P752
[4]   Heater orientation effects on pool boiling of micro-porous-enhanced surfaces in saturated FC-72 [J].
Chang, JY ;
You, SM .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1996, 118 (04) :937-943
[5]   Nucleate boiling of FC-72 and HFE-7100 on porous graphite at different orientations and liquid subcooling [J].
El-Genk, Mohamed S. ;
Parker, Jack L. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (04) :733-750
[6]   Saturation boiling of HFE-7100 from a copper surface, simulating a microelectronic chip [J].
El-Genk, MS ;
Bostanci, H .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (10) :1841-1854
[7]   Combined effects of subcooling and surface orientation on pool boiling of HFE-7100 from a simulated electronic chip [J].
El-Genk, MS ;
Bostanci, H .
EXPERIMENTAL HEAT TRANSFER, 2003, 16 (04) :281-301
[8]   TRANSIENT BOILING FROM INCLINED AND DOWNWARD-FACING SURFACES IN A SATURATED POOL [J].
ELGENK, MS ;
GUO, ZX .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (06) :414-422
[9]   CHF MECHANISM IN FLOW BOILING FROM A SHORT HEATED WALL .1. EXAMINATION OF NEAR-WALL CONDITIONS WITH THE AID OF PHOTOMICROGRAPHY AND HIGH-SPEED VIDEO IMAGING [J].
GALLOWAY, JE ;
MUDAWAR, I .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1993, 36 (10) :2511-2526
[10]  
Ho J.Y., 2014, P INT HEAT TRANSF C