Validity of shoe-type inertial measurement units for Parkinson's disease patients during treadmill walking

被引:31
作者
Lee, Myeounggon [1 ]
Youm, Changhong [2 ]
Jeon, Jeanhong [2 ]
Cheon, Sang-Myung [3 ]
Park, Hwayoung [1 ]
机构
[1] Dong A Univ, Coll Hlth Sci, Biomech Lab, Hadan 2 Dong, Busan, South Korea
[2] Dong A Univ, Dept Hlth Care & Sci, Coll Hlth Sci, 37 Nakdong Daero 550 Beon Gil,Hadan 2 Dong, Busan, South Korea
[3] Dong A Univ, Sch Med, Dept Neurol, Dongdaesin Dong 3 Ga, Busan, South Korea
来源
JOURNAL OF NEUROENGINEERING AND REHABILITATION | 2018年 / 15卷
关键词
Parkinson's disease; Inertial measurement unit; Spatiotemporal parameter; Gait; Validity; GAIT VARIABILITY; SYSTEM; PARAMETERS; SENSORS; ACCELEROMETER; RELIABILITY; MOVEMENT;
D O I
10.1186/s12984-018-0384-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: When examining participants with pathologies, a shoe-type inertial measurement unit (IMU) system with sensors mounted on both the left and right outsoles may be more useful for analysis and provide better stability for the sensor positions than previous methods using a single IMU sensor or attached to the lower back and a foot However, there have been few validity analyses of shoe-type IMU systems versus reference systems for patients with Parkinson's disease (PD) walking continuously with a steady-state gait in a single direction. Therefore, the purpose of this study is to assess the validity of the shoe-type IMU system versus a 3D motion capture system for patients with PD during 1 min of continuous walking on a treadmill. Methods: Seventeen participants with PD successfully walked on a treadmill for 1 min. The shoe-type IMU system and a motion capture system comprising nine infrared cameras were used to collect the treadmill walking data with participants moving at their own preferred speeds. All participants took anti-parkinsonian medication at least 3 h before the treadmill walk An intraclass correlation coefficient analysis and the associated 95% confidence intervals were used to evaluate the validity of the resultant linear acceleration and spatiotemporal parameters for the IMU and motion capture systems. Results: The resultant linear accelerations, cadence, left step length, right step length, left step time, and right step time showed excellent agreement between the shoe-type IMU and motion capture systems. Conclusions: The shoe-type IMU system provides reliable data and can be an alternative measurement tool for objective gait analysis of patients with PD in a clinical environment.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Validity of shoe-type inertial measurement units for Parkinson’s disease patients during treadmill walking
    Myeounggon Lee
    Changhong Youm
    Jeanhong Jeon
    Sang-Myung Cheon
    Hwayoung Park
    Journal of NeuroEngineering and Rehabilitation, 15
  • [2] Gait Characteristics Based on Shoe-Type Inertial Measurement Units in Healthy Young Adults during Treadmill Walking
    Lee, Myeounggon
    Youm, Changhong
    Noh, Byungjoo
    Park, Hwayoung
    SENSORS, 2020, 20 (07)
  • [3] Mechanisms involved in treadmill walking improvements in Parkinson's disease
    Bello, Olalla
    Marquez, Gonzalo
    Camblor, Miguel
    Fernandez-Del-Olmo, Miguel
    GAIT & POSTURE, 2010, 32 (01) : 118 - 123
  • [4] Familiarization to treadmill walking in unimpaired Parkinson's disease patients
    Isaac Perez-Sanpablo, Alberto
    Hernandez-Arenas, Claudia
    Rodriguez-Reyes, Gerardo
    Quinones-Uriostegui, Ivett
    Alessi Montero, Aldo
    Nunez-Carrera, Lidia
    Catherine Boll-Woehrlen, Marie
    Galvan Duque-Gastelum, Carlos
    REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 2014, 66 : S24 - S31
  • [5] Gait evaluation using inertial measurement units in subjects with Parkinson's disease
    Zago, Matteo
    Sforza, Chiarella
    Pacifici, Ilaria
    Cimolin, Veronica
    Camerota, Filippo
    Celletti, Claudia
    Condoluci, Claudia
    De Pandis, Maria Francesca
    Galli, Manuela
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 42 : 44 - 48
  • [6] Treadmill walking in Parkinson's disease patients: Adaptation and generalization effect
    Bello, Olalla
    Sanchez, Jose Andres
    Fernandez-del-Olmo, Miguel
    MOVEMENT DISORDERS, 2008, 23 (09) : 1243 - 1249
  • [7] Spatiotemporal Parameters of Gait During Treadmill and Overground Walking in Parkinson's Disease
    Bello, Olalla
    Sanchez, Jose Andres
    Vazquez-Santos, Cristina
    Fernandez-Del-Olmo, Miguel
    JOURNAL OF PARKINSONS DISEASE, 2014, 4 (01) : 33 - 36
  • [8] Treadmill walking alters stride time dynamics in Parkinson's disease
    Hollman, John H.
    Von Arb, Hannah M.
    Budreck, Allison M.
    Muehlemann, Allyson
    Ness, Debra K.
    GAIT & POSTURE, 2020, 77 : 195 - 200
  • [9] Testing the Validity of a Spatiotemporal Gait Model Using Inertial Measurement Units in Early Parkinson's Patients
    Tao, Shuai
    Wang, Haoye
    Kong, Liwen
    Lv, Zeping
    Wang, Zumin
    IEEE ACCESS, 2023, 11 : 80573 - 80587
  • [10] Effects of treadmill training on walking economy in Parkinson's disease: a pilot study
    Pelosin, Elisa
    Faelli, Emanuela
    Lofrano, Francesco
    Avanzino, Laura
    Marinelli, Lucio
    Bove, Marco
    Ruggeri, Piero
    Abbruzzese, Giovanni
    NEUROLOGICAL SCIENCES, 2009, 30 (06) : 499 - 504