3-D ULTRASOUND SEGMENTATION OF THE PLACENTA USING THE RANDOM WALKER ALGORITHM: RELIABILITY AND AGREEMENT

被引:34
作者
Stevenson, Gordon N. [1 ,2 ]
Collins, Sally L. [3 ,4 ]
Ding, Jane [3 ]
Impey, Lawrence [4 ]
Noble, J. Alison [1 ]
机构
[1] Univ Oxford, Dept Engn Sci, Inst Biomed Engn, Oxford OX1 3PJ, England
[2] Rosie Hosp, Evelyn Perinatal Imaging Ctr, Cambridge CB2 1QQ, England
[3] Univ Oxford, Nuffield Dept Obstet & Gynaecol, Oxford, England
[4] John Radcliffe Hosp, Womens Ctr, Fetal Med Unit, Oxford OX3 9DU, England
关键词
3-D ultrasound; Random walker; Placenta; Volume; Virtual organ computer-aided analysis (VOCAL); Repeatability; Agreement; Intra-class correlation coefficient; 3-DIMENSIONAL ULTRASOUND; VOLUME MEASUREMENT; EARLY-PREGNANCY; PREDICTION; MULTIPLANAR; SONOGRAPHY; GESTATION; VALIDITY; GROWTH;
D O I
10.1016/j.ultrasmedbio.2015.07.021
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Volumetric segmentation of the placenta using 3-D ultrasound is currently performed clinically to investigate correlation between organ volume and fetal outcome or pathology. Previously, interpolative or semi-automatic contour-based methodologies were used to provide volumetric results. We describe the validation of an original random walker (RW)-based algorithm against manual segmentation and an existing semi-automated method, virtual organ computer-aided analysis (VOCAL), using initialization time, inter-and intra-observer variability of volumetric measurements and quantification accuracy (with respect to manual segmentation) as metrics of success. Both semi-automatic methods require initialization. Therefore, the first experiment compared initialization times. Initialization was timed by one observer using 20 subjects. This revealed significant differences (p < 0.001) in time taken to initialize the VOCAL method compared with the RW method. In the second experiment, 10 subjects were used to analyze intra-/inter-observer variability between two observers. Bland-Altman plots were used to analyze variability combined with intra-and inter-observer variability measured by intra-class correlation coefficients, which were reported for all three methods. Intra-class correlation coefficient values for intra-observer variability were higher for the RW method than for VOCAL, and both were similar to manual segmentation. Inter-observer variability was 0.94 (0.88, 0.97), 0.91 (0.81, 0.95) and 0.80 (0.61, 0.90) for manual, RWand VOCAL, respectively. Finally, a third observer with no prior ultrasound experience was introduced and volumetric differences from manual segmentation were reported. Dice similarity coefficients for observers 1, 2 and 3 were respectively 0.84 +/- 0.12, 0.94 +/- 0.08 and 0.84 +/- 0.11, and the mean was 0.87 +/- 0.13. The RWalgorithm was found to provide results concordant with those for manual segmentation and to outperform VOCAL in aspects of observer reliability. The training of an additional untrained observer was investigated, and results revealed that with the appropriate initialization protocol, results for observers with varying levels of experience were concordant. We found that with appropriate training, the RW method can be used for fast, repeatable 3-D measurement of placental volume. (C) 2015 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:3182 / 3193
页数:12
相关论文
共 31 条
  • [1] [Anonymous], 2003, TECHNICAL REPORT
  • [2] COMPARISON OF 2-D AND 3-D ESTIMATES OF PLACENTAL VOLUME IN EARLY PREGNANCY
    Aye, Christina Y. L.
    Stevenson, Gordon N.
    Impey, Lawrence
    Collins, Sally L.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (03) : 734 - 740
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] VOLUMETRIC GROWTH OF HUMAN PLACENTA - LONGITUDINAL ULTRASONIC STUDY
    BLEKER, OP
    KLOOSTERMAN, GJ
    BREUR, W
    MIERAS, DJ
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1977, 127 (06) : 657 - 661
  • [5] Comparison of inter- and intraobserver agreement and reliability between three different types of placental volume measurement technique (XI VOCAL™, VOCAL™ and multiplanar) and validity in the in-vitro setting
    Cheong, K. B.
    Leung, K. Y.
    Li, T. K. T.
    Chan, H. Y.
    Lee, Y. P.
    Tang, M. H. Y.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (02) : 210 - 217
  • [6] Influence of power Doppler gain setting on Virtual Organ Computer-aided AnaLysis indices in vivo: can use of the individual sub-noise gain level optimize information?
    Collins, S. L.
    Stevenson, G. N.
    Noble, J. A.
    Impey, L.
    Welsh, A. W.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (01) : 75 - 80
  • [7] RAPID CALCULATION OF STANDARDIZED PLACENTAL VOLUME AT 11 TO 13 WEEKS AND THE PREDICTION OF SMALL FOR GESTATIONAL AGE BABIES
    Collins, Sally L.
    Stevenson, Gordon N.
    Noble, J. Alison
    Impey, Lawrence
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (02) : 253 - 260
  • [8] Random walks for image segmentation
    Grady, Leo
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2006, 28 (11) : 1768 - 1783
  • [9] PLACENTAL SIZE DURING EARLY-PREGNANCY AND FETAL-OUTCOME - A PRELIMINARY-REPORT OF A SEQUENTIAL ULTRASONOGRAPHIC STUDY
    HOOGLAND, HJ
    DEHAAN, J
    MARTIN, CB
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1980, 138 (04) : 441 - 443
  • [10] Reproducibility of Placental Volume and Vasculature Indices Obtained by 3-Dimensional Power Doppler Sonography
    Huster, Kristina M.
    Haas, Kimberly
    Schoenborn, Jean
    McVean, Dominique
    Odibo, Anthony O.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (06) : 911 - 916