Purpose: To evaluate the efficacy and safety of tube fenestrations in eyes undergoing polyglactin suture-ligated Baerveldt Glaucoma Implant surgery. Patients and Methods: The authors performed a retrospective nonrandomized comparative interventional study of consecutive cases of 111 eyes of 111 patients with refractory glaucoma who received polyglactin (Vicryl) suture-ligated Baerveldt 350 implants as a single procedure. In 69 of these cases (group 1), fenestrations were placed anterior to the ligature using a suture needle. In 42 cases (group 2), no fenestrations were performed. Main outcome measures, included intraocular pressure, visual acuity, and complications. Results: Mean (+/- SD) preoperative intraocular pressure was 36.7 +/- 10.2 mm Hg, in group 1 and 28.3 +/- 10.3 mm Hg in group 2 (P <0.001). Postoperative mean intraocular pressure was lower in group 1 than in group 2 at day 1 (20.2 +/- 12.8 vs. 29.3 +/- 1.9 mm Hg, P <0.001) and week 1 (18.3 +/- 10.4 vs. 23.7 +/- 8.6 mm Hg, P = 0.006), but was virtually identical at I year (12.7 +/- 4.9 vs. 12.6 +/- 4.4 mm Hg, P = 0.95). Number of glaucoma medications used by group 1 patients was significantly lower up to 3 months (P less than or equal to 0.05). Complication rates were similar in both groups. After tube opening at a mean of 36 +/- 4.7 days, there was an equal and Sustained intraocular pressure reduction in both groups in patients taking a similar number of glaucoma medicines up to 12 months after Surgery. Conclusion: Tube fenestrations provide safe and effective short-term intraocular pressure control with fewer glaucoma medications in a ligated nonvalved glaucoma drainage implant, with comparable intraocular pressure control and medications required at 1 year. However, not all patients have sustained reduction of intraocular pressure in the immediate postoperative period with fenestrations, making the effect somewhat unpredictable.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 50 条
  • [31] Comparison of Outcomes of Glaucoma Drainage Implant Surgery With or Without Prior Failed Trabeculectomy
    Dawson, Emily F.
    Rosenberg, Nicole C.
    Meyer, Alissa M.
    Culpepper, Brady E.
    Bolch, Charlotte A.
    Wilson, Mary K.
    Nguyen, Phuong T.
    Rodgers, Cooper D.
    Smith, Ryan J.
    Blake, Charles R.
    Sherwood, Mark B.
    JOURNAL OF GLAUCOMA, 2021, 30 (07) : 585 - 595
  • [32] Sonographic bleb visualisation after PAUL glaucoma implant surgery
    Weber, Constance
    Weinhold, Leonie
    Walz, Wolfgang
    Petrak, Michael
    Holz, Frank G.
    Liegl, Raffael
    Mercieca, Karl
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024,
  • [33] Effects of Miosis on Anterior Chamber Structure in Glaucoma Implant Surgery
    Park, Kee Sup
    Kim, Kyoung Nam
    Kim, Jaeyoung
    Lee, Yeon Hee
    Lee, Sung Bok
    Kim, Chang-sik
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (05) : 1 - 10
  • [34] DIABETIC MACULAR EDEMA AND CATARACT SURGERY Phacoemulsification Combined With Dexamethasone Intravitreal Implant Compared With Standard Phacoemulsification
    Furino, Claudio
    Boscia, Francesco
    Niro, Alfredo
    D'Addario, Maria
    Grassi, Maria O.
    Saglimbene, Valeria
    Reibaldi, Michele
    Alessio, Giovanni
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (05): : 1102 - 1109
  • [35] Combined Phacoemulsification and Ahmed Glaucoma Drainage Implant Surgery for Patients With Refractory Glaucoma and Cataract
    Valenzuela, Felipe
    Browne, Andrew
    Srur, Miguel
    Nieme, Carlos
    Zanolli, Mario
    Lopez-Solis, Remigio
    Traipe, Leonidas
    JOURNAL OF GLAUCOMA, 2016, 25 (02) : 162 - 166
  • [36] Effect of glaucoma drainage implant surgery on corneal topography: a prospective study
    Koivusalo, Riku
    Valimaki, Juha
    ACTA OPHTHALMOLOGICA, 2020, 98 (03) : 305 - 309
  • [37] Comparison of complications after Ahmed versus Baerveldt implant in glaucoma patients: one year follow-up
    Koentjoro, Sara Listyani
    Artini, Widya
    Soebijantoro, Iwan
    Istiantoro, Vira Wardhana
    Rusmayani, Emma
    Sulastiwaty, Rini
    Djamal, Zeiras Eka
    Akbar, Arini Safira Nurul
    Yoserizal, Muhammad
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (12) : 1908 - 1914
  • [38] Evaluation of Bleb Characteristics after Trabeculectomy and Glaucoma Implant Surgery in the Rabbit
    Ishida, Kyoko
    Nakano, Yukimichi
    Ojino, Kazuki
    Shimazawa, Masamitsu
    Otsuka, Tomohiro
    Inagaki, Satoshi
    Kawase, Kazuhide
    Hara, Hideaki
    Yamamoto, Tetsuya
    OPHTHALMIC RESEARCH, 2021, 64 (01) : 68 - 76
  • [39] Clinical outcomes of the PAUL® glaucoma implant: One-year results
    Weber, Constance
    Hundertmark, Sarah
    Liegl, Raffael
    Jauch, Anna S.
    Stasik, Isabel
    Holz, Frank G.
    Mercieca, Karl
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (06) : 566 - 576
  • [40] XEN-augmented Baerveldt drainage device implantation in refractory glaucoma: 1-year outcomes
    Giorgio Enrico Bravetti
    Kaweh Mansouri
    Kevin Gillmann
    Harsha L. Rao
    André Mermoud
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1787 - 1794