Network for the detection of stratospheric change fourier transform infrared intercomparison at Table Mountain Facility, November 1996

被引:43
作者
Goldman, A [1 ]
Paton-Walsh, C
Bell, W
Toon, GC
Blavier, JF
Sen, B
Coffey, MT
Hannigan, JW
Mankin, WG
机构
[1] Univ Denver, Dept Phys, Denver, CO 80208 USA
[2] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[3] Natl Ctr Atmospher Res, Div Chem, Boulder, CO 80307 USA
[4] CALTECH, Jet Prop Lab, Pasadena, CA USA
关键词
D O I
10.1029/1999JD900879
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
An intercomparison of four Fourier transform infrared (FTIR) spectrometers, operated side by side by Jet Propulsion Laboratory (JPL), National Center for Atmospheric Research, and National Physical Laboratory groups, using two different spectral fitting algorithms, was conducted at JPL's Table Mountain Facility (TMF) during November 1996. A "blind" comparison of retrieved vertical column amounts, of preselected trace gases in preselected microwindows (mw), and subsequent reanalysis of the results are described. The species analyzed are N-2 (3 mw), HF (1 mw), HCl (1 mw), CH4 (1 mw), O-3 (2 mw), N2O (2 mw), HNO3 (2 mw), and CO2 (1 mw). The column agreements from the "blind" phase were within 0.5-2%, except that for HNO3, HF, and O-3 the disagreement of the results was up to 10%, 5%, and 4%, respectively. It was found that several systematic effects were neglected in the "blind" phase analysis. Taking these into account in the postanalysis reduced the disagreements to 0.5-1.0% for most cases, and to less than 4%, 3%, and 1% for HNO3, HF, and O-3 respectively. It was concluded that zero offsets caused by detector nonlinearity were the main cause of the large errors in HNO3 and other gases (i.e., CO2) retrieved from the HgCdTe spectra. At shorter wavelengths (i.e., HF) we conclude that incomplete modeling of the instrument line shapes (ILS) was the main cause of column differences larger than 1%.
引用
收藏
页码:30481 / 30503
页数:23
相关论文
共 25 条
[1]   PRACTICAL EXAMPLE OF THE CORRECTION OF FOURIER-TRANSFORM SPECTRA FOR DETECTOR NONLINEARITY [J].
ABRAMS, MC ;
TOON, GC ;
SCHINDLER, RA .
APPLIED OPTICS, 1994, 33 (27) :6307-6314
[2]   Improved vibration-rotation (0-1) HBr line parameters for validating high resolution infrared atmospheric spectra measurements [J].
Coffey, MT ;
Goldman, A ;
Hannigan, JW ;
Mankin, WG ;
Schoenfeld, WG ;
Rinsland, CP ;
Bernardo, C ;
Griffith, DWT .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1998, 60 (05) :863-867
[3]  
FARMER CB, 1987, MIKROCHIM ACTA, V3, P189, DOI 10.1007/BF01201690
[4]  
GOLDMAN A, 1995, NDSC INFR WORK GROUP
[5]  
GOLDMAN A, 1996, NDSC INFR WORK GROUP
[6]  
GUELACHVILI G, 1981, SPECTROMETRIC TECHNI, V2, P1
[7]   Analysis of the instrumental line shape of high-resolution Fourier transform IR spectrometers with gas cell measurements and new retrieval software [J].
Hase, F ;
Blumenstock, T ;
Paton-Walsh, C .
APPLIED OPTICS, 1999, 38 (15) :3417-3422
[8]   LINE-SHAPE DISTORTIONS IN MISALIGNED CUBE CORNER INTERFEROMETERS [J].
KAUPPINEN, J ;
SAARINEN, P .
APPLIED OPTICS, 1992, 31 (01) :69-74
[9]  
Kurylo M.J, 1991, SPIE, V1491, P168
[10]   Comparison of Arctic and Antarctic trace gas column abundances from ground-based Fourier transform infrared spectrometry [J].
Notholt, J ;
Toon, GC ;
Lehmann, R ;
Sen, B ;
Blavier, JF .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1997, 102 (11D) :12863-12869