The controlled-drift detector

被引:24
|
作者
Castoldi, A
Gatti, E
Guazzoni, C
Longoni, A
Rehak, P
Strüder, L
机构
[1] Politecn Milan, I-20133 Milan, Italy
[2] Brookhaven Natl Lab, Upton, NY 11973 USA
[3] MPI Halbleiterlab, D-81739 Munich, Germany
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2000年 / 439卷 / 2-3期
关键词
X-ray imaging; fast read-out; X-ray detectors;
D O I
10.1016/S0168-9002(99)00903-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new position-sensing X-ray detector is presented, The novel device is called Controlled-Drift Detector (CDD). The detector is fully depleted and is operated by switching between integration and drift modes, The relevant details of the detector design are discussed. A complete experimental characterization of the fast readout of the integrated signal charges achievable with static drift fields in the range 100-400 V/cm has been carried out. Preliminary measurements to evaluate the charge-handling capacity are also shown. The CDD can provide unambiguous two-dimensional position measurement, high-resolution X-ray spectroscopy and time resolution below 1 ms. (C) 2000 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:519 / 528
页数:10
相关论文
共 50 条
  • [1] The Controlled-Drift Detector:: a new detector for fast frame readout X-ray imaging
    Castoldi, A
    Gatti, E
    Guazzoni, C
    Longoni, A
    Rehak, P
    Strüder, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3): : 405 - 409
  • [2] Room-temperature 2-D X-ray imaging with the controlled-drift detector
    Castoldi, A
    Cattaneo, G
    Galimberti, A
    Guazzoni, C
    Rehak, P
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 989 - 994
  • [3] Principle and applications of controlled-drift detectors
    Castoldi, A.
    Guazzoni, C.
    Hartmann, R.
    Strueder, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 79 - 82
  • [4] Application of controlled-drift detectors in diffraction enhanced Imaging of tissues
    Castoldi, Andrea
    Guazzoni, Chiara
    Galimberti, Antonio
    Hartmann, Robert
    Pani, Silvia
    Royle, Gary
    Stueder, Lothar
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1474 - 1480
  • [5] Evaluation of Controlled-Drift Detectors in X-Ray Spectroscopic Imaging Applications
    Castoldi, Andrea
    Guazzoni, Chiara
    Ozkan, Cigdem
    Vedani, Giorgio
    Hartmann, Robert
    Bjeoumikhov, Aniouar
    MICROSCOPY AND MICROANALYSIS, 2009, 15 (03) : 231 - 236
  • [6] Spectroscopic-grade X-ray imaging up to 100-kHz frame rate with controlled-drift detectors
    Castoldi, A
    Guazzoni, C
    Rehak, P
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 982 - 986
  • [7] Performance characteristics of CdTe drift ring detector
    Alruhaili, A.
    Sellin, P. J.
    Lohstroh, A.
    Veeramani, P.
    Kazemi, S.
    Veale, M. C.
    Sawhney, K. J. S.
    Kachkanov, V.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [8] CdZnTe drift detector with correction for hole trapping
    van Pamelen, MAJ
    Budtz-Jorgensen, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 411 (01): : 197 - 200
  • [9] Development of a CZT drift ring detector for X and γ ray spectroscopy
    Alruhaili, A.
    Sellin, P. J.
    Lohstroh, A.
    Boothman, V.
    Veeramani, P.
    Veale, M. C.
    Sawhney, K. J. S.
    Kachkanov, V.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [10] Synchrotron study of charge transport in a CZT ring-drift detector
    den Hartog, Roland
    Owens, A.
    Kozorezov, A. G.
    Wigmore, J. K.
    Gostilo, V.
    Webb, M. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 (01): : 155 - 162