Advanced Musculoskeletal Applications of Dual-Energy Computed Tomography

被引:38
作者
Wong, William D. [1 ]
Shah, Samad [1 ]
Murray, Nicolas [1 ]
Walstra, Frances [1 ]
Khosa, Faisal [1 ]
Nicolaou, Sawas [1 ]
机构
[1] Vancouver Gen Hosp, Dept Radiol, 899 West 12th Ave, Vancouver, BC V5Z 1M9, Canada
关键词
Dual-energy CT; Musculoskeletal; Gout; Bone marrow edema; Artifact reduction; Tendons; Ligaments; BONE-MARROW EDEMA; METAL ARTIFACT REDUCTION; ANTERIOR CRUCIATE LIGAMENT; MINERAL DENSITY; VERTEBRAL FRACTURES; INITIAL-EXPERIENCE; PERFORMANCE EVALUATION; TOPHACEOUS GOUT; CT ARTHROGRAPHY; KNEE LIGAMENTS;
D O I
10.1016/j.rcl.2018.03.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dual-energy computed tomography (DECT) is a rapidly growing tool in musculoskeletal radiology. It has been validated as an accurate imaging modality for the assessment of gout and bone marrow edema. DECT can be used to reduce metal artifacts. A few studies have shown its ability to calculate bone mineral density and examine pathologic states in tendons and ligaments. Its capacity for material separation suggests its emergence as a technique for arthrography and for the evaluation of intervertebral discs and other inflammatory arthropathies.
引用
收藏
页码:587 / +
页数:15
相关论文
共 72 条
  • [1] Dual-Energy Computed Tomography Arthrography of the Shoulder Joint Using Virtual Monochromatic Spectral Imaging: Optimal Dose of Contrast Agent and Monochromatic Energy Level
    An, Chansik
    Chun, Yong-Min
    Kim, Sungjun
    Lee, Young Han
    Yun, Min Jeong
    Suh, Jin-Suck
    Song, Ho-Taek
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (06) : 746 - 756
  • [2] Pitfalls in the measurement of bone mineral density by dual energy X-ray absorptiometry
    Antonacci, D
    Hanson, DS
    Heggeness, MH
    [J]. SPINE, 1996, 21 (01) : 87 - 90
  • [3] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [4] Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI
    Bierry, Guillaume
    Venkatasamy, Aina
    Kremer, Stephane
    Dosch, Jean-Claude
    Dietemann, Jean-Louis
    [J]. SKELETAL RADIOLOGY, 2014, 43 (04) : 485 - 492
  • [5] DXA in vivo BMD methodology:: An erroneous and misleading research and clinical gauge of bone mineral status, bone fragility, and bone remodelling
    Bolotin, H. H.
    [J]. BONE, 2007, 41 (01) : 138 - 154
  • [6] Inaccuracies inherent in dual-energy X-ray absorptiometry in vivo bone mineral density can seriously mislead diagnostic/prognostic interpretations of patient-specific bone fragility
    Bolotin, HH
    Sievänen, H
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (05) : 799 - 805
  • [7] Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study
    Bongartz, Tim
    Glazebrook, Katrina N.
    Kavros, Steven J.
    Murthy, Naveen S.
    Merry, Stephen P.
    Franz, Walter B., III
    Michet, Clement J.
    Veetil, Barath M. Akkara
    Davis, John M., III
    Mason, Thomas G., II
    Warrington, Kenneth J.
    Ytterberg, Steven R.
    Matteson, Eric L.
    Crowson, Cynthia S.
    Leng, Shuai
    McCollough, Cynthia H.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2015, 74 (06) : 1072 - 1077
  • [8] Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025
    Burge, Russel
    Dawson-Hughes, Bess
    Solomon, Daniel H.
    Wong, John B.
    King, Alison
    Tosteson, Anna
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 (03) : 465 - 475
  • [9] Good interrater reliability of a new grading system in detecting traumatic bone marrow lesions in the knee by dual energy CT virtual non-calcium images
    Cao, Jian-xin
    Wang, Yi-min
    Kong, Xiang-quan
    Yang, Cheng
    Wang, Peng
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (06) : 1109 - 1115
  • [10] Visualization of joint and bone using dual-energy CT arthrography with contrast subtraction: in vitro feasibility study using porcine joints
    Chai, Jee Won
    Choi, Jung-Ah
    Choi, Ja-Young
    Kim, Sujin
    Hong, Sung Hwan
    Kang, Heung Sik
    [J]. SKELETAL RADIOLOGY, 2014, 43 (05) : 673 - 678