Four-Minute Bone SPECT Using Large-Field Cadmium-Zinc-Telluride Camera

被引:14
作者
Gregoire, Bastien [1 ,2 ]
Pina-Jomir, Geraldine [1 ,2 ]
Bani-Sadr, Alexandre [1 ]
Moreau-Triby, Caroline [1 ]
Janier, Marc [1 ,2 ]
Scheiber, Christian [1 ,2 ]
机构
[1] Grp Hosp Est, Hosp Civils Lyon, Serv Med Nucl, Bron, France
[2] Univ Claude Bernard Lyon 1, Fac Med Lyon Est, Lyon, France
关键词
bone SPECT; lesion detectability; time reduction; whole-body CZT camera; SINGLE-PHOTON; SCINTIGRAPHY; PERFORMANCE; TOMOGRAPHY; GUIDELINES; TIME; CZT; CT;
D O I
10.1097/RLU.0000000000002062
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The aim of this study was to determine the minimum acquisition time without decreasing lesion detectability of bone SPECT using a whole-body cadmium-zinc-telluride camera. Methods Patients referred for bone SPECT were retrospectively included. SPECT of 30 patients were reframed from native data (16 s/projection) to produce 10-, 5-, and 3-s/projection data sets. A critical acquisition time/projection was defined as that below which the SPECT quality becomes insufficient for interpretation, as determined by 3 reviewers using a 4-point scale (0 = quality insufficient for interpretation, 1 = average, 2 = good, 3 = excellent). Three reviewers (blinded to the acquisition time) evaluated SPECT data sets (n = 79), native and reframed with critical acquisition times, in a randomized order. A lesion was defined as any uptake considered pathological by a reviewer. Lesion detectability equivalence between native SPECT and reframed SPECT was assessed by calculating a coefficient () for each reviewer. Results Image quality of the first sample (n = 30) was significantly and progressively less well graded for the reframed data sets by all reviewers. Only 1 patient was graded 0 by each reviewer for the 5-s/projection data set. For the 3-s/projection data set, 3 patients were graded 0. No patients were graded 0 for 10-s/projection data set. The minimal acquisition time, for each projection, was defined as 5 s/projection. The coefficient , between native and reframed, with critical acquisition time/projection SPECT was greater than 0.9 for each reviewer. Conclusions The more contrasted images of the cadmium-zinc-telluride camera allow performance of 5-s/projection SPECT without loss of lesion detectability. This suggests the possibility of performing whole-body SPECT in a reasonable time or reducing injected doses, especially in pediatric patients.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 27 条
[1]   Clinical evaluation of reducing acquisition time on single-photon emission computed tomography image quality using proprietary resolution recovery software [J].
Aldridge, Matthew D. ;
Waddington, Wendy W. ;
Dickson, John C. ;
Prakash, Vineet ;
Ell, Peter J. ;
Bomanji, Jamshed B. .
NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (11) :1116-1123
[2]   Half-Time SPECT Myocardial Perfusion Imaging with Attenuation Correction [J].
Ali, Iftikhar ;
Ruddy, Terrence D. ;
Almgrahi, Abdulaziz ;
Anstett, Frank G. ;
Wells, R. Glenn .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) :554-562
[3]   Bone scintigraphy: procedure guidelines for tumour imaging [J].
Bombardieri, E ;
Aktolun, C ;
Baum, RP ;
Bishof-Delaloye, A ;
Buscombe, J ;
Chatal, JF ;
Maffioli, L ;
Moncayo, R ;
Mortelmans, L ;
Reske, SN .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) :BP99-BP106
[4]   EMISSION COMPUTER-ASSISTED TOMOGRAPHY WITH SINGLE-PHOTON AND POSITRON-ANNIHILATION PHOTON EMITTERS [J].
BUDINGER, TF ;
DERENZO, SE ;
GULLBERG, GT ;
GREENBERG, WL ;
HUESMAN, RH .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :131-145
[5]  
Delbeke D, 2006, J NUCL MED, V47, P1227
[7]   Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology [J].
Erlandsson, Kjell ;
Kacperski, Krzysztof ;
van Gramberg, Dean ;
Hutton, Brian F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (09) :2635-2649
[8]   Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras [J].
Esteves, Fabio P. ;
Raggi, Paolo ;
Folks, Russell D. ;
Keidar, Zohar ;
Askew, J. Wells ;
Rispler, Shmuel ;
O'Connor, Michael K. ;
Verdes, Liudmilla ;
Garcia, Ernest V. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (06) :927-934
[9]   Clinical Utility of SPECT-(Low-Dose)CT Versus SPECT Alone in Patients Presenting for Bone Scintigraphy [J].
Franc, Benjamin L. ;
Myers, Richard ;
Pounds, Thomas R. ;
Bolton, George ;
Conte, Frederic ;
Bartheld, Margo ;
Da Silva, Angela J. .
CLINICAL NUCLEAR MEDICINE, 2012, 37 (01) :26-34
[10]   Molecular Breast Imaging: Use of a Dual-Head Dedicated Gamma Camera to Detect Small Breast Tumors [J].
Hruska, Carrie B. ;
Phillips, Stephen W. ;
Whaley, Dana H. ;
Rhodes, Deborah J. ;
O'Connor, Michael K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (06) :1805-1815