PREDICTION OF SURGICAL VIEW OF NEUROVASCULAR DECOMPRESSION USING INTERACTIVE COMPUTER GRAPHICS

被引:45
|
作者
Kin, Taichi [1 ]
Oyama, Hiroshi [2 ]
Kamada, Kyousuke
Aoki, Shigeki [3 ]
Ohtomo, Kuni [3 ]
Saito, Nobuhito
机构
[1] Tokyo Univ Hosp, Dept Neurosurg, Bunkyo Ku, Tokyo 1138655, Japan
[2] Tokyo Univ Hosp, Grad Sch Med, Dept Clin Informat Engn, Tokyo 1138655, Japan
[3] Tokyo Univ Hosp, Dept Radiol, Tokyo 1138655, Japan
关键词
Computer graphics; Fusion image; Interactive graphics; Magnetic resonance imaging; Microvascular decompression; Neurovascular compression; Virtual reality; MICROVASCULAR DECOMPRESSION; TRIGEMINAL NEURALGIA; HEMIFACIAL SPASM; 3-DIMENSIONAL VISUALIZATION; CEREBELLOPONTINE ANGLE; CRANIAL NERVES; TECHNICAL NOTE; MRI; COMPRESSION; ANGIOGRAMS;
D O I
10.1227/01.NEU.0000347890.19718.0A
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To assess the value of an interactive visualization method for detecting the offending vessels in neurovascular compression syndrome in patients with facial spasm and trigeminal neuralgia. Computer graphics models are created by fusion of fast imaging employing steady-state acquistion and magnetic resonance angiography. METHODS: High-resolution magnetic resonance angiography and fast imaging employing steady acquisition were performed preoperatively in 17 patients with neurovascular compression syndromes (facial spasm, n = 10; trigeminal neuralgia, n = 7) using a 3.0-T magnetic resonance imaging scanner. Computer graphics models were created with computer software and observed interactively for detection of offending vessels by rotation, enlargement, reduction, and retraction on a graphic workstation. Two-dimensional images were reviewed by 2 radiologists blinded to the clinical details, and 2 neurosurgeons predicted the offending vessel with the interactive visualization method before surgery predictions from the 2 imaging approaches were compared with surgical findings. The vessels identified during surgery were assumed to be the true offending vessels. RESULTS: Offending vessels were identified correctly in 16 of 17 patients (94%) using the interactive visualization method and in 10 of 17 patients using 2-dimenstional images. These data demonstrrated a significant difference (P = 0.015 by Fishers exact method). CONCLUSION: The interactive visualization method data corresponded well with surgical findings (surgical field offending vessels and nerves). Virtual reality 3-dimensional computer graphics using fusion magnetic resonance angiography and fast imaging employing steady-state acquistion may be helpful for preoperative simulation.
引用
收藏
页码:121 / 129
页数:9
相关论文
共 50 条
  • [21] Surgical Outcome and Improvement in Quality of Life after Microvascular Decompression for Hemifacial Spasms: A Case Series Assessment Using a Validated Disease-Specific Scale
    Ray, Dibyendu K.
    Bahgat, Diaa
    McCartney, Shirley
    Burchiel, Kim J.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2010, 88 (06) : 383 - 389
  • [22] Computer graphics, interactive technologies and collaborative learning synergy supporting individuals' skills development
    Franco, Jorge Ferreira
    Da Cruz, Sandra Regina
    De Deus Lopes, Roseli
    ACM SIGGRAPH 2006 Educators Program - International Conference on Computer Graphics and Interactive Techniques, 2006,
  • [23] Microvascular decompression for hemifacial spasm caused by the vertebral artery: A simple and effective transposition method using surgical glue
    Kurokawa, Y
    Maeda, Y
    Toyooka, T
    Inaba, KI
    SURGICAL NEUROLOGY, 2004, 61 (04): : 398 - 403
  • [24] Interactive computer graphics and volumetric visualization for EHD lubrication of point contacts
    Sadeghi, F
    Anderson, DC
    Ortiz, JM
    LUBRICATION ENGINEERING, 1996, 52 (04): : 287 - 298
  • [25] CodeRunnerGL - An Interactive Web-Based Tool for Computer Graphics Teaching and Assessment
    Wunsche, Burkhard C.
    Huang, Edward
    Shaw, Lindsay
    Suselo, Thomas
    Leung, Kai-Cheung
    Dimalen, Davis
    van der Mark, Wannes
    Luxton-Reilly, Andrew
    Lobb, Richard
    2019 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2019, : 171 - 177
  • [26] STESYS: Computer graphics SW supporting semi-automatic, interactive stereology
    Karen, P
    Krekule, I
    Kubinova, L
    ITAB '97 - INFORMATION TECHNOLOGY APPLICATIONS IN BIOMEDICINE, PROCEEDINGS, 1997, : 93 - 94
  • [27] INTERACTIVE GRAPHICS SYSTEM USING AN OVERLAY TABLET.
    Corbett, C.
    Digital Processes, 1976, 2 (04): : 291 - 306
  • [28] Using computer graphics to improve programming skills
    Slaby, Antonin
    Jezek, Bruno
    Vanek, Jan
    INTERNATIONAL JOURNAL OF CONTINUING ENGINEERING EDUCATION AND LIFE-LONG LEARNING, 2005, 15 (3-6) : 185 - 193
  • [29] Neurosurgical Virtual Reality Simulation for Brain Tumor Using High-definition Computer Graphics: A Review of the Literature
    Kin, Taichi
    Nakatomi, Hirofumi
    Shono, Naoyuki
    Nomura, Seiji
    Saito, Toki
    Oyama, Hiroshi
    Saito, Nobuhito
    NEUROLOGIA MEDICO-CHIRURGICA, 2017, 57 (10) : 513 - 520
  • [30] Exploring spatial data by using interactive graphics and local statistics
    Wilhelm, A
    Steck, R
    JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1998, 47 : 423 - 430