Validation of a new noninvasive method to measure blood pressure and assess baroreflex sensitivity in preterm infants during sleep

被引:30
作者
Yiallourou, Stephanie R. [1 ]
Walker, Adrian M. [1 ]
Horne, Rosemary S. C. [1 ]
机构
[1] Monash Univ, Monash Inst Med Res, Ritchie Ctr Baby Hlth Res, Melbourne, Vic 3004, Australia
关键词
blood pressure; baroreflex; sleep; cardiovascular control;
D O I
10.1093/sleep/29.8.1083
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Accuracy and precision of a noninvasive device for continuously measuring blood pressure (BP) (Finometer (TM), FMS, The Netherlands) during sleep was assessed in preterm infants. Design: Absolute BP beat-to-beat values, interbeat changes, measurement precision, and baroreflex sensitivity were compared with BP measurements from intraarterial catheters. Participants: Ten preterm infants (gestational age 27-36 weeks; birth weight 964-2620 gm) were studied in the neonatal intensive care unit. Measurements and Results: The 2 modes of BP measurement were compared in 2-minute epochs (n = 10-12/infant). Mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure were analyzed beat to beat, and baroreflex sensitivity was assessed using spontaneous sequence analysis. Mean differences for absolute BP (mm Hg) were as follows: mean arterial pressure, 3 (limits of agreement, -1 to 8); systolic arterial pressure, -4 (-8 to 1); and diastolic arterial pressure, 7 (4 to 10). Mean differences and limits of agreement for interbeat changes were essentially 0 for mean arterial pressure, systolic arterial pressure, and diastolic arterial pressure. Precision ( 95% confidence intervals, mm Hg) for the Finometer (TM) were mean arterial pressure +/- 7, systolic arterial pressure 8, and diastolic arterial pressure +/- 6. Precision was greater for the arterial catheter (mean arterial pressure 3, systolic arterial pressure 4, and diastolic arterial pressure 4). Baroreflex sensitivity calculated from the Finometer (TM) BP was (mean +/- SEM, ms/mm Hg) 1.74 +/- 0.23 and, from the catheter system, BP was 1.56 +/- 0.21 (p value NS). Conclusions: The Finometer (TM) provides accurate measurements of beat-to-beat BP and baroreflex sensitivity. The ability to continuously measure BP and baroreflex sensitivity during sleep in infants may provide vital clues into pathologic conditions associated with impaired autonomic control during sleep.
引用
收藏
页码:1083 / 1088
页数:6
相关论文
共 23 条
  • [1] Twenty-four-hour ambulatory blood pressure in children with sleep-disordered breathing
    Amin, RS
    Carroll, JL
    Jeffries, JL
    Grone, C
    Bean, JA
    Chini, B
    Bokulic, R
    Daniels, SR
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 169 (08) : 950 - 956
  • [2] Blood pressure and heart rate response to head-up position in full-term newborns
    Andrasyova, D
    Kellerova, E
    [J]. EARLY HUMAN DEVELOPMENT, 1996, 44 (03) : 169 - 178
  • [3] Noninvasive assessment of blood pressure variability in preterm infants
    Andriessen, P
    Schoffelen, RLM
    Berendsen, RCM
    De Beer, NAM
    Oei, SG
    Wijn, PFF
    Blanco, CE
    [J]. PEDIATRIC RESEARCH, 2004, 55 (02) : 220 - 223
  • [4] EVALUATION OF BARORECEPTOR REFLEX BY BLOOD-PRESSURE MONITORING IN UNANESTHETIZED CATS
    BERTINIERI, G
    DIRIENZO, M
    CAVALLAZZI, A
    FERRARI, AU
    PEDOTTI, A
    MANCIA, G
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (02): : H377 - H383
  • [5] METHODOLOGY OF SPONTANEOUS BAROREFLEX RELATIONSHIP ASSESSED BY SURROGATE DATA-ANALYSIS
    BLABER, AP
    YAMAMOTO, Y
    HUGHSON, RL
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (04): : H1682 - H1687
  • [6] COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1995, 346 (8982): : 1085 - 1087
  • [7] Effect of prone sleeping on circulatory control in infants
    Chong, A
    Murphy, N
    Matthews, T
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 2000, 82 (03) : 253 - 256
  • [8] Assessment of spontaneous baroreflex sensitivity in neonates
    Drouin, E
    Gournay, V
    Calamel, J
    Mouzard, A
    Roze, JC
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1997, 76 (02): : F108 - F112
  • [9] Feasibility of using finger arterial pressure in neonates
    Drouin, E
    Gournay, V
    Calamel, J
    Mouzard, A
    Roze, JC
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1997, 77 (02): : F139 - F140
  • [10] Sleep position, autonomic function, and arousal
    Galland, BC
    Reeves, G
    Taylor, BJ
    Bolton, DPG
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1998, 78 (03): : F189 - F194