Risk-Adjusted CUSUM Analysis of the Learning Curve of Femtosecond Laser Assisted Cataract Surgery

被引:6
作者
Roberts, Harry W. [1 ,2 ]
Wagh, Vijay B. [1 ]
Sung, Justin [3 ]
Ni, Melody Z. [4 ]
O'Brart, David P. S. [1 ,2 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Dept Ophthalmol, London SE1 7EH, England
[2] Kings Coll London, London, England
[3] Univ Auckland, Auckland, New Zealand
[4] St Marys Hosp, Imperial Coll London, Dept Surg & Canc, London, England
关键词
Cataract; phacoemulsification; femtosecond laser assisted cataract surgery; learning curve; CUSUM analysis; INTRAOPERATIVE MIOSIS; CORNEAL INCISIONS; PROSTAGLANDIN E-2; PHACOEMULSIFICATION; EXPERIENCE; OUTCOMES; SAFETY;
D O I
10.1080/02713683.2019.1601742
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To determine the length of the learning curve of femtosecond laser-assisted cataract surgery (FLACS) by a risk-adjusted cumulative sum method. Materials and Methods: This was a retrospective review of the first 288 FLACS performed by three surgeons over a 12-month period. The learning curves were analyzed separately for each surgeon and as pooled data via risk-adjusted cumulative sum methods. Change-point analysis was performed to estimate the length of the learning curve. Results: Rates of complications were as follows: anterior capsular tear (ACT) (3.4%), posterior capsular rupture (PCR) (0.7%), vitreous loss (0.3%), iris trauma (0.7%), Descemet's membrane tear (0.3%). There was a strong confidence level (96%) that there was a stable performance in terms of PCR after case 16 for the pooled data. Surgeon 1 did not have any cases of PCR, surgeons 2 and 3 exhibited change points at case 5 and 16, respectively (confidence levels = 99%, 98%). There was a strong confidence level (99.8%) that there was stable performance in terms of ACT after case 14 for the pooled data, however the individual surgeons demonstrated individual change points at case 1 (surgeon 1, confidence 99%), case 14 (surgeon 2, confidence 99%), and case 49 (surgeon 3, confidence 96%). Conclusions: The results suggest that there is an increased risk of ACT and PCR in FLACS within a surgeon's first 14 and 16 operations, respectively. Measures should be adopted to minimize harm to patients during this phase. However, overall rates of complications were safe.
引用
收藏
页码:887 / 895
页数:9
相关论文
共 50 条
[31]   Femtosecond laser cataract surgery: challenging cases [J].
Martin, Aifric I. ;
Hodge, Christopher ;
Lawless, Michael ;
Roberts, Tim ;
Hughes, Paul ;
Sutton, Gerard .
CURRENT OPINION IN OPHTHALMOLOGY, 2014, 25 (01) :71-80
[32]   Femtosecond laser-assisted cataract in vitreoretinal surgery [J].
Rizzo, Stanislao ;
Bacherini, Daniela ;
Faraldi, Francesco ;
Pellegrini, Marco ;
Mariotti, Cesare .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (05) :565-568
[33]   Incidence and analysis of intraoperative complications in femtosecond laser-assisted cataract surgery: a large-scale cohort study to establish the learning curve [J].
Zhang, Xiaobo ;
Xu, Wen ;
Shentu, Xingchao ;
Chen, Peiqing ;
Yu, Yibo ;
Lai, Kairan ;
Li, Jiayong ;
Wang, Wei ;
Chen, Xinyi ;
Yao, Ke .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2024, 108 (11) :1521-1526
[34]   Femtosecond-laser assisted cataract surgery: a review [J].
Abouzeid, Hana ;
Ferrini, Walter .
ACTA OPHTHALMOLOGICA, 2014, 92 (07) :597-603
[35]   Femtosecond laser assisted cataract surgery followed by coaxial phacoemulsification or microincisional cataract surgery: differences and advantages [J].
Alio, Jorge L. ;
Soria, Felipe ;
Abdou, Ahmed A. .
CURRENT OPINION IN OPHTHALMOLOGY, 2014, 25 (01) :81-88
[36]   Dry Eye Following Femtosecond Laser-Assisted Cataract Surgery: A Meta-Analysis [J].
Chen, Wei-Tsun ;
Chen, Yu-Yen ;
Hung, Man-Chen .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
[37]   Femtosecond Laser Assisted Cataract Surgery: A Review [J].
Agarwal, Kanika ;
Hatch, Kathryn .
SEMINARS IN OPHTHALMOLOGY, 2021, 36 (08) :618-627
[38]   Lens capsule-related complications in femtosecond laser-assisted cataract surgery: a study based on video analysis [J].
Wang, Wei ;
Chen, Xinyi ;
Liu, Xin ;
Zhang, Xiaobo ;
Lyu, Danni ;
Yao, Ke .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (07) :906-911
[39]   Femtosecond laser-assisted cataract surgery versus 2.2 mm clear corneal phacoemulsification [J].
Ranjini, H. ;
Murthy, Praveen R. ;
Murthy, Gowri J. ;
Murthy, Vinay R. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (10) :942-948
[40]   Perioperative pupil size in low-energy femtosecond laser-assisted cataract surgery [J].
Mirshahi, Alireza ;
Schneider, Astrid ;
Latz, Catharina ;
Ponto, Katharina A. .
PLOS ONE, 2021, 16 (05)