Optimization of X-ray microplanar beam radiation therapy for deep-seated tumors by a simulation study

被引:10
|
作者
Shinohara, Kunio [1 ]
Kondoh, Takeshi [2 ,3 ]
Nariyama, Nobuteru [4 ]
Fujita, Hajime [1 ]
Washio, Masakazu [1 ]
Aoki, Yukimasa [5 ]
机构
[1] Waseda Univ, Res Inst Sci & Engn, Shinjuku Ku, Tokyo 1698555, Japan
[2] Kobe Univ, Grad Sch Med, Dept Neurosurg, Kobe, Hyogo 657, Japan
[3] Shinsuma Gen Hosp, Kobe, Hyogo, Japan
[4] Japan Synchrotron Radiat Res Inst, Kobe, Hyogo, Japan
[5] Med Corp YUKOUKAI Clin, Funabashi, Chiba, Japan
基金
日本学术振兴会;
关键词
Microbeam radiation therapy; X-rays; Monte Carlo simulation; transverse dose distribution; energy dependence; IN-VIVO; 9L GLIOSARCOMA; MICROBEAM; SYNCHROTRON; BRAIN; IRRADIATION; PALLIATION; TOLERANCE; EFFICACY; TISSUES;
D O I
10.3233/XST-140434
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Monte Carlo simulation was applied to study the energy dependence on the transverse dose distribution of microplanar beam radiation therapy (MRT) for deep-seated tumors. The distribution was found to be the peak (in-beam) dose and the decay from the edge of the beam down to the valley. The area below the same valley dose level (valley region) was decreased with the increase in the energy of X-rays at the same beam separation. To optimize the MRT, we made the following two assumptions: the therapeutic gain may be attributed to the efficient recovery of normal tissue caused by the beam separation; and a key factor for the efficient recovery of normal tissue depends on the area size of the valley region. Based on these assumptions and the results of the simulated dose distribution, we concluded that the optimum X-ray energy was in the range of 100-300 keV depending on the effective peak dose to the target tumors and/or tolerable surface dose. In addition, we proposed parameters to be studied for the optimization of MRT to deep-seated tumors.
引用
收藏
页码:395 / 406
页数:12
相关论文
共 50 条
  • [41] Diagnosing Transverse Profile of Ion Beam Using Off-Target X-Ray Radiation
    Skobliakov, A. V.
    Kantsyrev, A. V.
    Panyushkin, V. A.
    Bogdanov, A. V.
    Volkov, V. A.
    Golubev, A. A.
    Zaehter, S.
    Gyrdymov, M.
    Rosmej, O. N.
    PHYSICS OF ATOMIC NUCLEI, 2022, 85 (09) : 1546 - 1550
  • [42] SYNTHESIS AND MONTE CARLO SIMULATION OF IMPROVED CONCRETE COMPOSITES FOR ENHANCED X-RAY/GAMMA RAY RADIATION SHIELDING
    Aziz, Ferhat
    Panitra, Mardiyanto
    Rivai, Abu Khalid
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2018, 9 (04) : 695 - 706
  • [43] Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy
    Martinez-Rovira, I.
    Sempau, J.
    Fernandez-Varea, J. M.
    Bravin, A.
    Prezado, Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15) : 4375 - 4388
  • [44] Fast beam monitor diamond-based devices for VUV and X-ray synchrotron radiation applications
    Di Fraia, Michele
    De Sio, Antonio
    Antonelli, Matias
    Nesti, Renzo
    Panella, Dario
    Menk, Ralf H.
    Cautero, Giuseppe
    Coreno, Marcello
    Catone, Daniele
    Zema, Nicola
    Callegari, Carlo
    Pace, Emanuele
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 386 - 392
  • [45] Absorbers for medical X-ray detectors with optimum spatial resolution: a simulation study
    Hoheisel, M
    Giersch, J
    Mitschke, M
    Bernhardt, P
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 386 - 395
  • [46] Numerical simulation and method study of X-ray litho-density logging
    Yu, Hua-Wei
    Zhang, Yu-Xin
    Chen, Xiang-Hong
    Wang, Wen-Ding
    Liu, Chao-Zhuo
    NUCLEAR SCIENCE AND TECHNIQUES, 2020, 31 (12)
  • [47] Numerical simulation and method study of X-ray litho-density logging
    Hua-Wei Yu
    Yu-Xin Zhang
    Xiang-Hong Chen
    Wen-Ding Wang
    Chao-Zhuo Liu
    Nuclear Science and Techniques, 2020, 31
  • [48] Assessment of various polymer materials for enhanced radiation protection in X-ray imaging modalities: A comprehensive Monte Carlo simulation study
    Mansouri, Sofiene
    RADIATION PHYSICS AND CHEMISTRY, 2025, 234
  • [49] Hydrogenated amorphous silicon high flux x-ray detectors for synchrotron microbeam radiation therapy
    Large, Matthew J.
    Bizzarri, Marco
    Calcagnile, Lucio
    Caprai, Mirco
    Caricato, Anna Paola
    Catalano, Roberto
    Cirrone, Giuseppe A. P.
    Croci, Tommaso
    Cuttone, Giacomo
    Dunand, Sylvain
    Fabi, Michele
    Frontini, Luca
    Gianfelici, Benedetta
    Grimani, Catia
    Ionica, Maria
    Kanxheri, Keida
    Lerch, Michael L. F.
    Liberali, Valentino
    Martino, Maurizio
    Maruccio, Giuseppe
    Mazza, Giovanni
    Menichelli, Mauro
    Monteduro, Anna Grazia
    Moscatelli, Francesco
    Morozzi, Arianna
    Pallotta, Stefania
    Papi, Andrea
    Passeri, Daniele
    Pedio, Maddalena
    Petringa, Giada
    Peverini, Francesca
    Piccolo, Lorenzo
    Placidi, Pisana
    Quarta, Gianluca
    Rizzato, Silvia
    Rossi, Alessandro
    Rossi, Giulia
    de Rover, Vincent
    Sabbatini, Federico
    Servoli, Leonello
    Stabile, Alberto
    Talamonti, Cinzia
    Tosti, Luca
    Villani, Mattia
    Wheadon, Richard J.
    Wyrsch, Nicolas
    Zema, Nicola
    Petasecca, Marco
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (13)
  • [50] Evaluation of radiation dose to organs of neonatal patients during portable X-ray examination in incubators: A Monte Carlo simulation study
    Kim, Eunhye
    Park, Hyemin
    Kim, Kwanghyun
    Yoon, Yongsu
    Lim, Cheonghwan
    Kim, Jungmin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (02) : 333 - 342