Optimization of X-ray microplanar beam radiation therapy for deep-seated tumors by a simulation study

被引:10
|
作者
Shinohara, Kunio [1 ]
Kondoh, Takeshi [2 ,3 ]
Nariyama, Nobuteru [4 ]
Fujita, Hajime [1 ]
Washio, Masakazu [1 ]
Aoki, Yukimasa [5 ]
机构
[1] Waseda Univ, Res Inst Sci & Engn, Shinjuku Ku, Tokyo 1698555, Japan
[2] Kobe Univ, Grad Sch Med, Dept Neurosurg, Kobe, Hyogo 657, Japan
[3] Shinsuma Gen Hosp, Kobe, Hyogo, Japan
[4] Japan Synchrotron Radiat Res Inst, Kobe, Hyogo, Japan
[5] Med Corp YUKOUKAI Clin, Funabashi, Chiba, Japan
基金
日本学术振兴会;
关键词
Microbeam radiation therapy; X-rays; Monte Carlo simulation; transverse dose distribution; energy dependence; IN-VIVO; 9L GLIOSARCOMA; MICROBEAM; SYNCHROTRON; BRAIN; IRRADIATION; PALLIATION; TOLERANCE; EFFICACY; TISSUES;
D O I
10.3233/XST-140434
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Monte Carlo simulation was applied to study the energy dependence on the transverse dose distribution of microplanar beam radiation therapy (MRT) for deep-seated tumors. The distribution was found to be the peak (in-beam) dose and the decay from the edge of the beam down to the valley. The area below the same valley dose level (valley region) was decreased with the increase in the energy of X-rays at the same beam separation. To optimize the MRT, we made the following two assumptions: the therapeutic gain may be attributed to the efficient recovery of normal tissue caused by the beam separation; and a key factor for the efficient recovery of normal tissue depends on the area size of the valley region. Based on these assumptions and the results of the simulated dose distribution, we concluded that the optimum X-ray energy was in the range of 100-300 keV depending on the effective peak dose to the target tumors and/or tolerable surface dose. In addition, we proposed parameters to be studied for the optimization of MRT to deep-seated tumors.
引用
收藏
页码:395 / 406
页数:12
相关论文
共 50 条
  • [31] Optimization by Monte Carlo method of photon fluence from the X-ray beam spectrum in a bimodal tomographic system
    Olaya Davila, H.
    Martinez-Ovalle, S. A.
    Castro Serrato, H. F.
    Vega-Carrillo, H. R.
    APPLIED RADIATION AND ISOTOPES, 2018, 141 : 228 - 233
  • [32] Study of a new portable X-ray source with micro-beam
    Wang, KG
    Li, J
    Yang, QL
    Guo, JC
    Guo, BP
    Kuo, XM
    Zhou, JL
    Niu, HB
    2ND INTERNATIONAL CONFERENCE ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, 2006, 6149
  • [33] Physiologically gated micro-beam radiation therapy using electronically controlled field emission x-ray source array
    Chtcheprov, Pavel
    Hadsell, Michael
    Burk, Laurel
    Ger, Rachel
    Zhang, Lei
    Yuan, Hong
    Lee, Yueh Z.
    Chang, Sha
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [34] Monte Carlo simulation of an x-ray volume imaging cone beam CT unit
    Spezi, Emiliano
    Downes, Patrick
    Radu, Emil
    Jarvis, Richard
    MEDICAL PHYSICS, 2009, 36 (01) : 127 - 136
  • [35] Boosting the tumor bed from deep-seated tumors in early-stage breast cancer: A planning study between electron, photon, and proton beams
    Toscas, Jose I.
    Linero, Dolors
    Rubio, Isabel
    Hidalgo, Alberto
    Arnalte, Raquel
    Escude, Lluis
    Cozzi, Luca
    Fogliata, Antonella
    Miralbell, Raymond
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 (02) : 192 - 198
  • [36] X-ray/γ-ray/Ultrasound-Activated Persistent Luminescence Phosphors for Deep Tissue Bioimaging and Therapy
    Wei, Yurong
    Wang, Jie
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (42) : 56519 - 56544
  • [37] Synchrotron x-ray spectra characterisation for radiation therapy applications at the ESRF-ID17 biomedical beamline
    Di Manici, Ilaria
    Reyes-Herrera, Juan
    Day, Liam
    Del Rio, Manuel Sanchez
    Krisch, Michael
    Pellicioli, Paolo
    PHYSICA SCRIPTA, 2024, 99 (06)
  • [38] Intrinsic spatial resolution of semiconductor X-ray detectors: a simulation study
    Hoheisel, M
    Giersch, J
    Bernhardt, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2) : 75 - 81
  • [39] Dose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation
    Chicilo, F.
    Hanson, A. L.
    Geisler, F. H.
    Belev, G.
    Edgar, A.
    Ramaswami, K. O.
    Chapman, D.
    Kasap, S. O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (07)
  • [40] Diagnosing Transverse Profile of Ion Beam Using Off-Target X-Ray Radiation
    A. V. Skobliakov
    A. V. Kantsyrev
    V. A. Panyushkin
    A. V. Bogdanov
    V. A. Volkov
    A. A. Golubev
    S. Zähter
    M. Gyrdymov
    O. N. Rosmej
    Physics of Atomic Nuclei, 2022, 85 : 1546 - 1550