Optimization of X-ray microplanar beam radiation therapy for deep-seated tumors by a simulation study

被引:10
|
作者
Shinohara, Kunio [1 ]
Kondoh, Takeshi [2 ,3 ]
Nariyama, Nobuteru [4 ]
Fujita, Hajime [1 ]
Washio, Masakazu [1 ]
Aoki, Yukimasa [5 ]
机构
[1] Waseda Univ, Res Inst Sci & Engn, Shinjuku Ku, Tokyo 1698555, Japan
[2] Kobe Univ, Grad Sch Med, Dept Neurosurg, Kobe, Hyogo 657, Japan
[3] Shinsuma Gen Hosp, Kobe, Hyogo, Japan
[4] Japan Synchrotron Radiat Res Inst, Kobe, Hyogo, Japan
[5] Med Corp YUKOUKAI Clin, Funabashi, Chiba, Japan
基金
日本学术振兴会;
关键词
Microbeam radiation therapy; X-rays; Monte Carlo simulation; transverse dose distribution; energy dependence; IN-VIVO; 9L GLIOSARCOMA; MICROBEAM; SYNCHROTRON; BRAIN; IRRADIATION; PALLIATION; TOLERANCE; EFFICACY; TISSUES;
D O I
10.3233/XST-140434
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Monte Carlo simulation was applied to study the energy dependence on the transverse dose distribution of microplanar beam radiation therapy (MRT) for deep-seated tumors. The distribution was found to be the peak (in-beam) dose and the decay from the edge of the beam down to the valley. The area below the same valley dose level (valley region) was decreased with the increase in the energy of X-rays at the same beam separation. To optimize the MRT, we made the following two assumptions: the therapeutic gain may be attributed to the efficient recovery of normal tissue caused by the beam separation; and a key factor for the efficient recovery of normal tissue depends on the area size of the valley region. Based on these assumptions and the results of the simulated dose distribution, we concluded that the optimum X-ray energy was in the range of 100-300 keV depending on the effective peak dose to the target tumors and/or tolerable surface dose. In addition, we proposed parameters to be studied for the optimization of MRT to deep-seated tumors.
引用
收藏
页码:395 / 406
页数:12
相关论文
共 50 条
  • [1] X-ray energy optimization in minibeam radiation therapy
    Prezado, Y.
    Thengumpallil, S.
    Renier, M.
    Bravin, A.
    MEDICAL PHYSICS, 2009, 36 (11) : 4897 - 4902
  • [2] Laue lens to focus an X-ray beam for radiation therapy
    Paterno, Gianfranco
    Marziani, Michele
    Camattari, Riccardo
    Bellucci, Valerio
    Mazzolari, Andrea
    Gambaccini, Mauro
    Guidi, Vincenzo
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2016, 49 : 468 - 478
  • [3] Experimental optimisation of the X-ray energy in microbeam radiation therapy
    Livingstone, Jayde
    Stevenson, Andrew W.
    Hausermann, Daniel
    Adam, Jean-Francois
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 156 - 161
  • [4] Enhanced electron beam and X-ray beam therapy by applying nanoparticle heterojunctions: A Monte Carlo simulation
    Zhang, Chuhan
    Li, Xiaoyi
    Lu, Jingbin
    Li, Chengqian
    Wang, Yu
    Xu, Xu
    Yang, Xiangshan
    APPLIED RADIATION AND ISOTOPES, 2023, 199
  • [5] Nanotube x-ray for cancer therapy: a compact microbeam radiation therapy system for brain tumor treatment
    Zhang, Lei
    Yuan, Hong
    Inscoe, Christina
    Chtcheprov, Pavel
    Hadsell, Michael
    Lee, Yueh
    Lu, Jianping
    Chang, Sha
    Zhou, Otto
    EXPERT REVIEW OF ANTICANCER THERAPY, 2014, 14 (12) : 1411 - 1418
  • [6] Study of the X-ray radiation interaction with a multislit collimator for the creation of microbeams in radiation therapy
    Pellicioli, P.
    Donzelli, M.
    Davis, J. A.
    Esteve, F.
    Hugtenburg, R.
    Guatelli, S.
    Petasecca, M.
    Lerch, M. L. F.
    Brauer-Krisch, E.
    Krisch, M.
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 392 - 403
  • [7] Monte Carlo simulation of stereotactic microbeam radiation therapy: evaluation of the usage of a linear accelerator as the x-ray source
    Gokeri, Gurdal
    Kocar, Cemil
    Tombakoglu, Mehmet
    Cecen, Yigit
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13) : 4621 - 4642
  • [8] X-Tream quality assurance in synchrotron X-ray microbeam radiation therapy
    Fournier, Pauline
    Cornelius, Iwan
    Donzelli, Mattia
    Requardt, Herwig
    Nemoz, Christian
    Petasecca, Marco
    Brauer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1180 - 1190
  • [9] Technical advances in x-ray microbeam radiation therapy
    Bartzsch, Stefan
    Corde, Stephanie
    Crosbie, Jeffrey C.
    Day, Liam
    Donzelli, Mattia
    Krisch, Michael
    Lerch, Michael
    Pellicioli, Paolo
    Smyth, Lloyd M. L.
    Tehei, Moeava
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (02)
  • [10] Low Dose of X-Ray-Excited Long-Lasting Luminescent Concave Nanocubes in Highly Passive Targeting Deep-Seated Hepatic Tumors
    Chen, Zheng-Zhe
    Wang, Liu-Chun
    Manoharan, Divinah
    Lee, Chin-Lai
    Wu, Lai-Chin
    Huang, Wan-Ting
    Huang, Eng-Yen
    Su, Chia-Hao
    Sheu, Hwo-Shuenn
    Yeh, Chen-Sheng
    ADVANCED MATERIALS, 2019, 31 (49)