Bilateral branch pulmonary artery valve implantation in repaired tetralogy of fallot

被引:4
|
作者
Bansal, Neha [1 ]
Kobayashi, Daisuke [1 ]
Forbes, Thomas J. [1 ]
Du, Wei [2 ]
Zerin, Jeffrey M. [3 ]
Joshi, Aparna [3 ]
Turner, Daniel R. [1 ]
机构
[1] Wayne State Univ, Childrens Hosp Michigan, Carmen & Ann Adams Dept Pediat, Div Cardiol,Sch Med, 3901 Beaubien Blvd, Detroit, MI 48201 USA
[2] Wayne State Univ, Dept Pediat, Detroit, MI 48202 USA
[3] Childrens Hosp Michigan, Dept Radiol, Detroit, MI 48201 USA
关键词
CONP - congenital heart disease; pediatrics; percutaneous intervention; PVD - pulmonary valve disease; PVT - percutaneous valve therapy; COST-ANALYSIS; REPLACEMENT; REGURGITATION; DEATH;
D O I
10.1002/ccd.27489
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundTranscatheter, bilateral branch pulmonary artery (PA) valve implantation is a novel treatment for patients with severe pulmonary insufficiency and oversized right ventricle (RV) outflow tract. There is scarce data on efficacy and safety of this approach. MethodsThis was a retrospective study of 8 patients with repaired tetralogy of fallot (TOF) who underwent bilateral branch PA valve implantation. Demographics, echocardiography, cardiac catheterization, and axial imaging data were reviewed. Variables were compared by a paired sample t-test. ResultsAll patients were adult sized (weight 43-99 kg) with oversized RV outflow tract not suitable for conventional transcatheter pulmonary valve implantation. Staged bare metal PA stenting followed by valve implantation (interval 3-5 months) was technically successful in 7 patients with one stent embolization. In another patient, proximal stent migration prevented placement of bilateral pulmonary valve stents. There were a total of 14 valved branch PA stents placed (Melody valve n=9, Sapien XT n=2, Sapien 3 n=3). In the 7 patients undergoing successful branch pulmonary valve placement, at median follow up of 10 months (range 3 months to 6 years), 13 (93%) valves had none/trivial insufficiency on echocardiography. Prevalve and postvalve implantation cardiac magnetic resonance imaging in five patients showed significant reduction of indexed RV end-diastolic volume (15227 to 105 +/- 15 mL/m(2), P<.001). ConclusionsTranscatheter, bilateral branch PA valve implantation was technically feasible with satisfactory efficacy and safety in patients with repaired TOF, severe pulmonary insufficiency, and oversized RV outflow tracts. Elimination of pulmonary insufficiency with this method resulted in reduced RV end-diastolic volume. This approach can be offered as an alternative to surgery, particularly in patients considered high risk for standard surgical placement and who are not candidates for the newer self-expanding valve prosthesis for placement in RV outflow tracts larger than 30 mm diameter.
引用
收藏
页码:911 / 919
页数:9
相关论文
共 50 条
  • [31] Complications of pulmonic valve endocarditis in repaired tetralogy of fallot
    Ashraf, Hasan
    Pandya, Kruti
    Wack, Matthew
    Sawada, Stephen
    JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2019, 29 (03) : 123 - 125
  • [32] Impact of surgical pulmonary valve replacement on ventricular mechanics in children with repaired tetralogy of Fallot
    Yim, D.
    Mertens, L.
    Morgan, C. T.
    Friedberg, M. K.
    Grosse-Wortmann, L.
    Dragulescu, A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (05): : 711 - 720
  • [33] Preventing ventricular arrhythmia after transcatheter pulmonary valve placement for repaired tetralogy of Fallot
    Moore, Jeremy P.
    HEART RHYTHM, 2024, 21 (02) : 239 - 240
  • [34] Considerations in pursuing the optimal timing for pulmonary valve replacement in repaired tetralogy of Fallot reply
    Ma, Kai
    Wang, Guanxi
    Li, Shoujun
    HEART, 2018, 104 (11) : 959 - 960
  • [35] EARLY CARDIAC REMODELLING AFTER PULMONARY VALVE REPLACEMENT IN PATIENTS WITH REPAIRED TETRALOGY OF FALLOT
    Heng, Ee Ling
    Gatzoulis, Michael A.
    Uebing, Anselm
    Sethia, Babulal
    Uemura, Hideki
    Smith, Gillian C.
    Diller, Gerhard-Paul
    McCarthy, Karen P.
    Ho, Siew Yen
    Li, Wei
    Wright, Piers
    Spadotto, Veronica
    Kilner, Philip J.
    Oldershaw, Paul
    Pennell, Dudley J.
    Shore, Darryl F.
    Babu-Narayan, Sonya V.
    HEART, 2016, 102 : A26 - A26
  • [36] Electrophysiological study prior to planned pulmonary valve replacement in patients with repaired tetralogy of Fallot
    Bouyer, Benjamin
    Jalal, Zackaria
    Daniel Ramirez, F.
    Derval, Nicolas
    Iriart, Xavier
    Duchateau, Josselin
    Roubertie, Francois
    Tafer, Nadir
    Tixier, Romain
    Pambrun, Thomas
    Cheniti, Ghassen
    Ascione, Ciro
    Yokoyama, Masaaki
    Kowalewski, Christopher
    Buliard, Samuel
    Chauvel, Remi
    Arnaud, Marine
    Hocini, Meleze
    Haissaguerre, Michel
    Jais, Pierre
    Cochet, Hubert
    Thambo, Jean-Benoit
    Sacher, Frederic
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (06) : 1395 - 1404
  • [37] Variability in Surgical Referral Patterns for Pulmonary Valve Replacement in Adults with Repaired Tetralogy of Fallot
    Wald, Rachel M.
    Lyseggen, Erik
    Oechslin, Erwin N.
    Webb, Gary D.
    Silversides, Candice K.
    CONGENITAL HEART DISEASE, 2009, 4 (04) : 231 - 238
  • [38] Long-Term Outcome Following Pulmonary Valve Replacement in Repaired Tetralogy of Fallot
    Al Mosa, Alqasem Fuad H.
    Madathil, Sreenath
    Bernier, Pierre-Luc
    Tchervenkov, Christo
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2021, 12 (05) : 616 - 627
  • [39] Impact of surgical pulmonary valve replacement on ventricular mechanics in children with repaired tetralogy of Fallot
    D. Yim
    L. Mertens
    C. T. Morgan
    M. K. Friedberg
    L. Grosse-Wortmann
    A. Dragulescu
    The International Journal of Cardiovascular Imaging, 2017, 33 : 711 - 720
  • [40] Pulmonary Valve Replacement Can be Delayed in Repaired Tetralogy of Fallot Patients with Preserved RVEF
    Ermis, Peter
    Franklin, Wayne
    Parekh, Dhaval
    CIRCULATION, 2012, 126 (21)