Bilateral branch pulmonary artery valve implantation in repaired tetralogy of fallot

被引:4
作者
Bansal, Neha [1 ]
Kobayashi, Daisuke [1 ]
Forbes, Thomas J. [1 ]
Du, Wei [2 ]
Zerin, Jeffrey M. [3 ]
Joshi, Aparna [3 ]
Turner, Daniel R. [1 ]
机构
[1] Wayne State Univ, Childrens Hosp Michigan, Carmen & Ann Adams Dept Pediat, Div Cardiol,Sch Med, 3901 Beaubien Blvd, Detroit, MI 48201 USA
[2] Wayne State Univ, Dept Pediat, Detroit, MI 48202 USA
[3] Childrens Hosp Michigan, Dept Radiol, Detroit, MI 48201 USA
关键词
CONP - congenital heart disease; pediatrics; percutaneous intervention; PVD - pulmonary valve disease; PVT - percutaneous valve therapy; COST-ANALYSIS; REPLACEMENT; REGURGITATION; DEATH;
D O I
10.1002/ccd.27489
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundTranscatheter, bilateral branch pulmonary artery (PA) valve implantation is a novel treatment for patients with severe pulmonary insufficiency and oversized right ventricle (RV) outflow tract. There is scarce data on efficacy and safety of this approach. MethodsThis was a retrospective study of 8 patients with repaired tetralogy of fallot (TOF) who underwent bilateral branch PA valve implantation. Demographics, echocardiography, cardiac catheterization, and axial imaging data were reviewed. Variables were compared by a paired sample t-test. ResultsAll patients were adult sized (weight 43-99 kg) with oversized RV outflow tract not suitable for conventional transcatheter pulmonary valve implantation. Staged bare metal PA stenting followed by valve implantation (interval 3-5 months) was technically successful in 7 patients with one stent embolization. In another patient, proximal stent migration prevented placement of bilateral pulmonary valve stents. There were a total of 14 valved branch PA stents placed (Melody valve n=9, Sapien XT n=2, Sapien 3 n=3). In the 7 patients undergoing successful branch pulmonary valve placement, at median follow up of 10 months (range 3 months to 6 years), 13 (93%) valves had none/trivial insufficiency on echocardiography. Prevalve and postvalve implantation cardiac magnetic resonance imaging in five patients showed significant reduction of indexed RV end-diastolic volume (15227 to 105 +/- 15 mL/m(2), P<.001). ConclusionsTranscatheter, bilateral branch PA valve implantation was technically feasible with satisfactory efficacy and safety in patients with repaired TOF, severe pulmonary insufficiency, and oversized RV outflow tracts. Elimination of pulmonary insufficiency with this method resulted in reduced RV end-diastolic volume. This approach can be offered as an alternative to surgery, particularly in patients considered high risk for standard surgical placement and who are not candidates for the newer self-expanding valve prosthesis for placement in RV outflow tracts larger than 30 mm diameter.
引用
收藏
页码:911 / 919
页数:9
相关论文
共 23 条
  • [21] LUNG-FUNCTION AND PULMONARY REGURGITATION LIMIT EXERCISE CAPACITY IN POSTOPERATIVE TETRALOGY OF FALLOT
    ROWE, SA
    ZAHKA, KG
    MANOLIO, TA
    HORNEFFER, PJ
    KIDD, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (02) : 461 - 466
  • [22] VanBelle E, 1997, CIRCULATION, V95, P438
  • [23] Cost-Analysis of Percutaneous Pulmonary Valve Implantation Compared to Surgical Pulmonary Valve Replacement
    Vergales, Jeffrey E.
    Wanchek, Tanya
    Novicoff, Wendy
    Kron, Irving L.
    Lim, D. Scott
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (07) : 1147 - 1153