Analysis of urinary methylated nucleosides of patients with coronary artery disease by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry

被引:13
作者
Li, Yanru [1 ]
Yu, Haiyi [2 ,3 ,4 ]
Zhao, Wei [2 ,3 ,4 ]
Xu, Xinye [2 ,3 ,4 ]
Zhou, Jiang [1 ]
Xu, Ming [2 ,3 ,4 ]
Gao, Wei [2 ,3 ,4 ]
Yuan, Gu [1 ]
机构
[1] Peking Univ, Coll Chem & Mol Engn, Beijing Natl Lab Mol Sci, Beijing 100871, Peoples R China
[2] Peking Univ Third Hosp, Key Lab Mol Cardiovasc Sci, Minist Educ, Dept Cardiol, Beijing, Peoples R China
[3] Peking Univ Third Hosp, Key Lab Mol Cardiovasc Sci, Minist Educ, Inst Vasc Med, Beijing, Peoples R China
[4] Minist Hlth, Key Lab Mol Cardiovasc Mol Biol & Regulatory Pept, Beijing, Peoples R China
关键词
POTENTIAL TUMOR-MARKERS; CANCER-PATIENTS; BREAST-CANCER; HEART-FAILURE; CLINICAL-DIAGNOSIS; COLORECTAL-CANCER; MS ANALYSIS; IDENTIFICATION; ANGIOTENSIN; PHENOTYPE;
D O I
10.1002/rcm.6986
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: In recent years, methylated nucleosides have been considered to be potential biomarkers to human diseases. The early diagnosis of coronary artery disease (CAD) is an unsolved problem in clinical cardiology. The aim of our study is to evaluate whether urinary methylated nucleosides can serve as useful biomarkers for CAD. METHODS: A solid-phase extraction (SPE) column was used for extraction and purification of methylated nucleosides in urine, and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) was employed for specific, sensitive and rapid determination of the urinary methylated nucleosides from patients with cardiac events. RESULTS: We have analyzed six methylated nucleosides (N-3-methylcytidine, N-1-methyladenosine, N-6-methyladenosine, N-2-methylguanosine, N-1-methylguanosine and N-2, N-2-dimethylguanosine) in urine from 51 patients with CAD and 25 non-CADcontrols byHPLC/ESI-MS/MS using selective reactionmonitoring (SRM). Our results have shown that there were significant differences in the N-6-methyladenosine levels from the patients and the non-CAD controls in the urine analyzed. CONCLUSIONS: The results have indicated that HPLC/ESI-MS/MS is a highly specific and sensitive tool to measure urinary methylated nucleosides for analysis of CAD. Our result has revealed that the evaluation of urinary methylated nucleosides might be helpful in the analysis of CAD by liquid chromatography/mass spectrometry. Therefore, this N-6-methyladenosine is worthy of further studies in the near future. Copyright (C) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:2054 / 2058
页数:5
相关论文
共 50 条
[21]   Ultra-high performance liquid chromatography tandem mass spectrometry for comprehensive analysis of urinary acylcarnitines [J].
Zuniga, Azeret ;
Li, Liang .
ANALYTICA CHIMICA ACTA, 2011, 689 (01) :77-84
[22]   Dereplication of known pregnane glycosides and structural characterization of novel pregnanes in Marsdenia tenacissima by high-performance liquid chromatography and electrospray ionization-tandem mass spectrometry [J].
McGarvey, Brian D. ;
Liao, Hui ;
Ding, Keyi ;
Wang, Xiaoling .
JOURNAL OF MASS SPECTROMETRY, 2012, 47 (06) :687-693
[23]   Pharmacokinetic and metabolism studies of bavachinin through ultra-high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry [J].
Qian, Jun ;
Xie, Fan ;
Shi, Yanhong ;
Li, Jinhang ;
Zhang, Liuqiang ;
Li, Yiming ;
Guo, Fujiang ;
Wang, Rui .
BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (10)
[24]   Quantitative analysis of tissue folate using ultra high-performance liquid chromatography tandem mass spectrometry [J].
Liu, Jia ;
Pickford, Russell ;
Meagher, Alan P. ;
Ward, Robyn L. .
ANALYTICAL BIOCHEMISTRY, 2011, 411 (02) :210-217
[25]   Pharmacokinetic Study of Nobiletin and Tangeretin in Rat Serum by High-Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry [J].
Manthey, John A. ;
Cesar, Thais B. ;
Jackson, Erin ;
Mertens-Talcott, Susanne .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (01) :145-151
[26]   Rapid identification of Vinca alkaloids by direct-injection electrospray ionisation tandem mass spectrometry and confirmation by high-performance liquid chromatography-mass spectrometry [J].
Zhou, H ;
Tai, YP ;
Sun, CR ;
Pan, YJ .
PHYTOCHEMICAL ANALYSIS, 2005, 16 (05) :328-333
[27]   Separation and identification of purine nucleosides in the urine of patients with malignant cancer by reverse phase liquid chromatography/electrospray tandem mass spectrometry [J].
Li, Hua-Yu ;
Wang, Shao-Min ;
Liu, Hong-Min ;
Bu, Shan-Shan ;
Li, Juan ;
Han, Dong ;
Zhang, Ming-zhi ;
Wu, Guang-Yin .
JOURNAL OF MASS SPECTROMETRY, 2009, 44 (05) :641-651
[28]   Quality control of processed Crataegi Fructus and its medicinal parts by ultra high performance liquid chromatography with electrospray ionization tandem mass spectrometry [J].
Yin, Fangzhou ;
Li, Lin ;
Chen, Yan ;
Lu, Tuling ;
Li, Weidong ;
Cai, Baochang ;
Yin, Wu .
JOURNAL OF SEPARATION SCIENCE, 2015, 38 (15) :2630-2639
[29]   Stability and Degradation of Caffeoylquinic Acids under Different Storage Conditions Studied by High-Performance Liquid Chromatography with Photo Diode Array Detection and High-Performance Liquid Chromatography with Electrospray Ionization Collision-Induced Dissociation Tandem Mass Spectrometry [J].
Xue, Meng ;
Shi, Hang ;
Zhang, Jiao ;
Liu, Qing-Quan ;
Guan, Jun ;
Zhang, Jia-Yu ;
Ma, Qun .
MOLECULES, 2016, 21 (07)
[30]   Analysis of 30 synthetic cannabinoids in oral fluid using liquid chromatography-electrospray ionization tandem mass spectrometry [J].
Kneisel, Stefan ;
Auwaerter, Volker ;
Kempf, Juergen .
DRUG TESTING AND ANALYSIS, 2013, 5 (08) :657-669