Analysis of microcystins using high-performance liquid chromatography and magnetic solid-phase extraction with silica-coated magnetite with cetylpyridinium chloride

被引:19
|
作者
Li, Qiuying [1 ]
Lian, Lili [1 ]
Wang, Xiyue [1 ]
Wang, Runnan [1 ]
Tian, Yuanyuan [1 ]
Guo, Xiaoyang [1 ]
Lou, Dawei [1 ]
机构
[1] Jilin Inst Chem Technol, Dept Analyt Chem, 45 Chengde St, Jilin 132022, Peoples R China
基金
中国国家自然科学基金;
关键词
high-performance liquid chromatography; magnetic solid-phase extraction; magnetite; microcystins; POLYCYCLIC AROMATIC-HYDROCARBONS; ENVIRONMENTAL WATER; EFFICIENT ENRICHMENT; PORE-WALLS; NANOPARTICLES; MICROSPHERES; SAMPLES; CORE; LR; MICROEXTRACTION;
D O I
10.1002/jssc.201601407
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microcystins (MCs), produced by freshwater cyanobacteria, can be serious water pollutants, so it is important to monitor their concentration in drinking water. We have developed a method for rapid and accurate determination of microcystin levels in environmental water, using magnetic solid-phase extraction and high-performance liquid chromatography with UV detection. The magnetic composite material, which was combined with cetylpyridinium chloride, was prepared by hydrothermal synthesis. The optimal extraction of microcystins in water sample was achieved by optimizing the amount of adsorbent, time of adsorption, ratio of eluting solvent, and volume of eluent. Under the optimal conditions, the limit of detection of MC-LR was 0.001 mu g/L, and the limit of quantification was 0.0028 mu g/L. The limit of detection of MC-RR was 0.001 mu g/L, and the limit of quantification was 0.003 mu g/L. These values are far lower than those established by the International Health Organization for the maximum concentration of microcystins in drinking water. The magnetic solid-phase extraction adsorbent used in this method has the advantages of simple preparation, low price, and easy solid-liquid separation, and it can be used for the rapid and sensitive monitoring of trace microcystins in environmental water samples.
引用
收藏
页码:1644 / 1650
页数:7
相关论文
共 50 条
  • [41] Magnetic solid-phase extraction using polydopamine-coated magnetic multiwalled carbon nanotube composites coupled with high performance liquid chromatography for the determination of chlorophenols
    Lu, Wenhui
    Fu, Shanchao
    Sun, Xiaoze
    Liu, Jie
    Zhu, Deyi
    Li, Jinhua
    Chen, Lingxin
    ANALYST, 2021, 146 (20) : 6252 - 6261
  • [42] Determination of malondialdehyde in biological samples by solid-phase extraction and high-performance liquid chromatography
    Bakalova, R
    Mileva, M
    Kotsev, C
    Bardarov, V
    Ribarov, S
    METHODS AND FINDINGS IN EXPERIMENTAL AND CLINICAL PHARMACOLOGY, 2000, 22 (05): : 267 - 269
  • [43] Determination of sulfonamides in livers using matrix solid-phase dispersion extraction high-performance liquid chromatography
    Zhang, Yupu
    Xu, Xu
    Qi, Xiao
    Gao, Wenquan
    Sun, Shuo
    Li, Xiaotian
    Jiang, Chengfei
    Yu, Aimin
    Zhang, Hanqi
    Yu, Yong
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (01) : 45 - 52
  • [44] Molecularly imprinted inorganic supports in high-performance liquid chromatography and solid-phase extraction
    Polyanina, D. A.
    Beklemishev, M. K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (03) : 277 - 286
  • [45] Study of solid-phase extraction for the determination of sequestering agents in river water by high-performance liquid chromatography
    Kemmei, Tomoko
    Kodama, Shuji
    Muramoto, Tatsuya
    Fujishima, Hironori
    Yamamoto, Atsushi
    Inoue, Yoshinori
    Hayakawa, Kazuichi
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (07) : 1109 - 1114
  • [46] Magnetic solid phase extraction coupled with high-performance liquid chromatography-diode array detection based on assembled magnetic covalent organic frameworks for selective extraction and detection of microcystins in aquatic foods
    Wang, Tianliang
    Xie, Hongzhen
    Cao, Yuting
    Xu, Qing
    Gan, Ning
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1685
  • [47] Molecularly imprinted inorganic supports in high-performance liquid chromatography and solid-phase extraction
    D. A. Polyanina
    M. K. Beklemishev
    Journal of Analytical Chemistry, 2015, 70 : 277 - 286
  • [48] Magnetic reduced graphene oxide functionalized with β-cyclodextrin as magnetic solid-phase extraction adsorbents for the determination of phytohormones in tomatoes coupled with high performance liquid chromatography
    Li, Na
    Chen, Juan
    Shi, Yan-Ping
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1441 : 24 - 33
  • [49] Determination of trace bisphenol A in environmental water by high-performance liquid chromatography using magnetic reduced graphene oxide based solid-phase extraction coupled with dispersive liquid-liquid microextraction
    Li, Danping
    Ma, Xiaoguo
    Wang, Rui
    Yu, Yumian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (05) : 1165 - 1172
  • [50] Adsorption and magnetic solid-phase extraction of cadmium and lead using magnetite modified with schiff bases
    El-Sheikh, Amjad H.
    Nofal, Fayrouz S.
    Shtaiwi, Majed H.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2019, 7 (04):