Analysis of microcystins using high-performance liquid chromatography and magnetic solid-phase extraction with silica-coated magnetite with cetylpyridinium chloride

被引:19
|
作者
Li, Qiuying [1 ]
Lian, Lili [1 ]
Wang, Xiyue [1 ]
Wang, Runnan [1 ]
Tian, Yuanyuan [1 ]
Guo, Xiaoyang [1 ]
Lou, Dawei [1 ]
机构
[1] Jilin Inst Chem Technol, Dept Analyt Chem, 45 Chengde St, Jilin 132022, Peoples R China
基金
中国国家自然科学基金;
关键词
high-performance liquid chromatography; magnetic solid-phase extraction; magnetite; microcystins; POLYCYCLIC AROMATIC-HYDROCARBONS; ENVIRONMENTAL WATER; EFFICIENT ENRICHMENT; PORE-WALLS; NANOPARTICLES; MICROSPHERES; SAMPLES; CORE; LR; MICROEXTRACTION;
D O I
10.1002/jssc.201601407
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microcystins (MCs), produced by freshwater cyanobacteria, can be serious water pollutants, so it is important to monitor their concentration in drinking water. We have developed a method for rapid and accurate determination of microcystin levels in environmental water, using magnetic solid-phase extraction and high-performance liquid chromatography with UV detection. The magnetic composite material, which was combined with cetylpyridinium chloride, was prepared by hydrothermal synthesis. The optimal extraction of microcystins in water sample was achieved by optimizing the amount of adsorbent, time of adsorption, ratio of eluting solvent, and volume of eluent. Under the optimal conditions, the limit of detection of MC-LR was 0.001 mu g/L, and the limit of quantification was 0.0028 mu g/L. The limit of detection of MC-RR was 0.001 mu g/L, and the limit of quantification was 0.003 mu g/L. These values are far lower than those established by the International Health Organization for the maximum concentration of microcystins in drinking water. The magnetic solid-phase extraction adsorbent used in this method has the advantages of simple preparation, low price, and easy solid-liquid separation, and it can be used for the rapid and sensitive monitoring of trace microcystins in environmental water samples.
引用
收藏
页码:1644 / 1650
页数:7
相关论文
共 50 条
  • [1] Cetylpyridinium chloride functionalized silica-coated magnetite microspheres for the solid-phase extraction and pre-concentration of ochratoxin A from environmental water samples with high-performance liquid chromatographic analysis
    Hu, Meihua
    Huang, Pengcheng
    Suo, Lili
    Wu, Fangying
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (11) : 2431 - 2437
  • [2] Rapid Determination of Phenolics in Food Packaging by Magnetic Solid-Phase Extraction and High-Performance Liquid Chromatography
    Ju, Shuangqiao
    Yang, Yaling
    Liu, Mousheng
    ANALYTICAL LETTERS, 2015, 48 (12) : 1830 - 1841
  • [3] Determination of patulin in apple juice using magnetic solid-phase extraction coupled with high-performance liquid chromatography
    Yu, Youwei
    Fan, Zhefeng
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2017, 34 (02): : 273 - 281
  • [4] Magnetic Solid-phase Extraction Coupled with High-Performance Liquid Chromatography for Pesticide Residues Analysis in Citrus Sample
    Huang, Si-Min
    Hu, Yu-Fei
    Chen, Yan-Long
    Li, Gong-Ke
    Xia, Ling
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (10) : 1392 - 1399
  • [5] Development of a magnetic solid-phase extraction coupled with high-performance liquid chromatography method for the analysis of polyaromatic hydrocarbons
    Ma, Yan
    Xie, Jiawen
    Jin, Jing
    Wang, Wei
    Yao, Zhijian
    Zhou, Qing
    Li, Aimin
    Liang, Ying
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (14) : 2517 - 2525
  • [6] Determination of 11 Phthalate Esters in Beverages by Magnetic Solid-Phase Extraction Combined with High-Performance Liquid Chromatography
    Yin, Shuo
    Yang, Yi
    Yang, Danni
    Li, Yongxin
    Jiang, Yang
    Wu, Ling
    Sun, Chengjun
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (05) : 1624 - 1631
  • [7] Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography
    Liu, Xiaomei
    Sun, Zhiwei
    Chen, Guang
    Zhang, Wanwan
    Cai, Yiping
    Kong, Rongmei
    Wang, Xiaoyan
    Suo, Yourui
    You, Jinmao
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1409 : 46 - 52
  • [8] Ionic-liquid-modified magnetic anoparticles as a solid-phase extraction adsorbent coupled with high-performance liquid chromatography for the determination of linear alkylbenzene sulfonates in water samples
    Lu, Junyu
    Ye, Fanggui
    Huang, Xiuxiang
    Wei, Lianqiang
    Yao, Dongmei
    Li, Shengying
    Miao Ouyang
    Lai, Hongfang
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (05) : 1133 - 1141
  • [9] Preparation of magnetic mesoporous silica composite for the solid-phase microextraction of diazinon and malathion before their determination by high-performance liquid chromatography
    Bazmandegan-Shamili, Alireza
    Shabani, Ali Mohammad Haji
    Dadfarnia, Shayessteh
    Moghadam, Masoud Rohani
    Saeidi, Mahboubeh
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (08) : 1731 - 1738
  • [10] Determination of four parabens in cosmetics by high-performance liquid chromatography with magnetic solid-phase and ionic dispersive liquid liquid extraction
    Gao, Xun
    Xu, Kai
    Chi, Miaomiao
    Li, Jiaojiao
    Suo, Lingzhe
    Zhu, Lin
    Chen, Kexin
    Mu, Jingqing
    REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 40 (01) : 161 - 172