A New Capsule Platinum Resistance Thermometer for Cryogenic Use

被引:1
|
作者
Courts, S. S. [1 ]
Krause, J. K. [1 ]
机构
[1] Lake Shore Cryotron Inc, Westerville, OH 43082 USA
关键词
thermometer; cryogenic thermometer; platinum resistance thermometer;
D O I
10.1063/1.4819534
中图分类号
O414.1 [热力学];
学科分类号
摘要
Standards grade platinum resistance thermometers (SPRTs) obtain their high stability in part due to the strain-free mounting of the sensing wire. The space required for this strain-free mounting normally results in thermometers on the order of 6 mm diameter by 40 mm length in size. While these SPRTs are acceptable in many applications, it is desirable to reduce the size as much as possible for cryogenic use where space is of major concern. For over 40 years Minco Products, Inc. provided a smaller alternative with their model S1059, a high-stability cryogenic capsule platinum resistance thermometer (PRT) packaged in a copper canister sized only 3.2 mm diameter by 9.7 mm length. The packaging was compatible for use over the 13 K to 533 K temperature range. Unfortunately, this product was discontinued in 2009. In its absence, Lake Shore Cryotronics, Inc., has worked with Advanced Sensing Products to develop a similarly sized replacement sensor for cryogenic use. The replacement capsule PRT is manufactured using the model S1059 design, but with modifications to reduce the chance of lead breakage at the epoxy-lead interface. Test devices have been fabricated and tested for temperature response and stability upon repeated calibration from 13 K to 330 K. The new sensor design features and performance data are presented in this work.
引用
收藏
页码:168 / 173
页数:6
相关论文
共 50 条
  • [41] On the measurements of very low temperatures XI A comparison of the platinum resistance thermometer with the hydrogen thermometer
    Onnes, HK
    PROCEEDINGS OF THE KONINKLIJKE AKADEMIE VAN WETENSCHAPPEN TE AMSTERDAM, 1907, 9 : 207 - 213
  • [42] A new form of resistance thermometer
    Brown, SL
    PHYSICAL REVIEW, 1915, 5 (02): : 126 - 134
  • [43] THE USE OF THE GALLIUM TRIPLE POINT IN PLATINUM RESISTANCE THERMOMETER INTERPOLATION BELOW 273.15-K
    KEMP, RC
    METROLOGIA, 1987, 24 (04) : 175 - 179
  • [44] Arguments for making use of a differential gas thermometer in cryogenic microcalorimetry
    Frantsuz, ET
    Gutmann, P
    METROLOGIA, 2003, 40 (04) : L6 - L8
  • [45] A RESISTANCE THERMOMETER FOR USE AT HELIUM TEMPERATURES
    PARKINSON, DH
    ROBERTS, LM
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1955, 68 (06): : 386 - 387
  • [46] Platinum Resistance Microsensor for Cryogenic Temperature Measurement
    Mei, Jiabing
    Liu, Jingquan
    Jiang, Shuidong
    Yang, Bin
    Yang, Chunsheng
    MICRO-NANO TECHNOLOGY XIV, PTS 1-4, 2013, 562-565 : 198 - 203
  • [47] THE PLATINUM RESISTANCE THERMOMETER RANGE OF THE INTERNATIONAL TEMPERATURE SCALE OF 1990
    CROVINI, L
    JUNG, HJ
    KEMP, RC
    LING, SK
    MANGUM, BW
    SAKURAI, H
    METROLOGIA, 1991, 28 (04) : 317 - 325
  • [49] Standard platinum resistance thermometer interpolations in a revised temperature scale
    White, D. R.
    Rourke, P. M. C.
    METROLOGIA, 2020, 57 (03)
  • [50] A Challenge to Improve High-Temperature Platinum Resistance Thermometer
    Tanaka, Y.
    Widiatmo, J. V.
    Harada, K.
    Kobayashi, T.
    Yamazawa, K.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2017, 38 (05)