X-Ray Micro-Beam Diffraction Determination of Full Stress Tensors in Cu TSVs

被引:0
|
作者
Okoro, Chukwudi [1 ]
Levine, Lyle E. [2 ]
Xu, Ruqing [3 ]
Tischler, Jonathan Z. [3 ]
Liu, Wenjun [3 ]
Kirillov, Oleg [1 ]
Hummler, Klaus [4 ]
Obeng, Yaw S. [1 ]
机构
[1] NIST, Semicond & Dimens Metrol Div, 100 Bur Dr, Gaithersburg, MD 20899 USA
[2] NIST, Mat Sci & Engn Div, Gaithersburg, MD 20899 USA
[3] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[4] SEMA TECH, Albany, NY 12203 USA
关键词
THROUGH-SILICON-VIAS; COPPER; IMPACT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report the first non-destructive, depth resolved determination of the full stress tensor in Cu through-silicon vias (TSVs), using synchrotron based micro-beam X-ray diffraction. Two adjacent Cu TSVs were studied; one deliberately capped with SiO2, the other without (uncapped). Both Cu TSVs were found to be in a state of tensile hydrostatic stress that fluctuated considerably with depth. The average hydrostatic stress across the capped and the uncapped Cu TSVs was found to be (99 MPa +/- 13 MPa) and (118 MPa +/- 18 MPa), respectively. This apparent disparity between the mean hydrostatic stresses is attributed to local differences in their microstructure, and not to the differences in capping.
引用
收藏
页码:648 / 652
页数:5
相关论文
共 50 条
  • [41] X-ray micro-beam focusing system for in situ investigation of single nanowire during MBE growth
    Hu, Wen
    Takahasi, Masamitu
    Kozu, Miwa
    Nakata, Yuka
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [42] X-ray diffraction in thermal treatments: Determination of residual austenite by X-ray diffraction
    Bach, M
    Broll, N
    Cornet, A
    Gaide, L
    JOURNAL DE PHYSIQUE IV, 1996, 6 (C4): : 887 - 895
  • [43] Ion and X-ray micro-beam induced charge collection and their applications in CVD diamond detector characterisation
    Vittone, E
    Lo Giudice, A
    Paolini, C
    Olivero, P
    Manfredotti, C
    Barrett, R
    Rigato, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 210 : 159 - 163
  • [44] DETERMINATION OF THE BENDING RADIUS AND DIFFRACTION PROFILE PARAMETERS FOR X-RAY ANALYZER CRYSTALS WITH X-RAY PARALLEL BEAM
    KOGAN, MT
    SHECHTMAN, VM
    CRYSTAL RESEARCH AND TECHNOLOGY, 1984, 19 (04) : 593 - 598
  • [45] Micro-beam X-ray absorption and fluorescence spectroscopies at GSECARS: APS beamline 131D
    Newville, M
    Sutton, S
    Rivers, M
    Eng, P
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 353 - 355
  • [46] Micro-beam X-ray absorption and fluorescence spectroscopies at GSECARS: APS beamline 13ID
    Newville, Matthew
    Sutton, Steve
    Rivers, Mark
    Eng, Peter
    Journal of Synchrotron Radiation, 1999, 6 (03): : 353 - 355
  • [47] A Micro-Beam X-Ray Scattering Beamline Dedicated to Life Science Research at NSLS-II
    Yang, Lin
    BIOPHYSICAL JOURNAL, 2013, 104 (02) : 184A - 184A
  • [48] Transmission-type miniature micro-beam modulated X-ray source based on space application
    Mou Huan
    Li Bao-Quan
    Cao Yang
    ACTA PHYSICA SINICA, 2016, 65 (14)
  • [49] STRESS MEASUREMENT BY X-RAY DIFFRACTION
    LETNER, HR
    MALOOF, SR
    JOURNAL OF APPLIED PHYSICS, 1954, 25 (11) : 1440 - 1440
  • [50] Stress analysis by X-ray diffraction
    Barrett, C. S.
    Gensamer, M.
    PHYSICS-A JOURNAL OF GENERAL AND APPLIED PHYSICS, 1936, 7 (01): : 1 - 8