X-Ray Micro-Beam Diffraction Determination of Full Stress Tensors in Cu TSVs

被引:0
|
作者
Okoro, Chukwudi [1 ]
Levine, Lyle E. [2 ]
Xu, Ruqing [3 ]
Tischler, Jonathan Z. [3 ]
Liu, Wenjun [3 ]
Kirillov, Oleg [1 ]
Hummler, Klaus [4 ]
Obeng, Yaw S. [1 ]
机构
[1] NIST, Semicond & Dimens Metrol Div, 100 Bur Dr, Gaithersburg, MD 20899 USA
[2] NIST, Mat Sci & Engn Div, Gaithersburg, MD 20899 USA
[3] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[4] SEMA TECH, Albany, NY 12203 USA
关键词
THROUGH-SILICON-VIAS; COPPER; IMPACT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report the first non-destructive, depth resolved determination of the full stress tensor in Cu through-silicon vias (TSVs), using synchrotron based micro-beam X-ray diffraction. Two adjacent Cu TSVs were studied; one deliberately capped with SiO2, the other without (uncapped). Both Cu TSVs were found to be in a state of tensile hydrostatic stress that fluctuated considerably with depth. The average hydrostatic stress across the capped and the uncapped Cu TSVs was found to be (99 MPa +/- 13 MPa) and (118 MPa +/- 18 MPa), respectively. This apparent disparity between the mean hydrostatic stresses is attributed to local differences in their microstructure, and not to the differences in capping.
引用
收藏
页码:648 / 652
页数:5
相关论文
共 50 条
  • [1] X-Ray Micro-Beam Diffraction Measurement of the Effect of Thermal Cycling on Stress in Cu TSV: A Comparative Study
    Okoro, Chukwudi
    Leyine, Lyle E.
    Xu, Ruqing
    Hummler, Klaus
    Obeng, Yaw
    2014 IEEE 64TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2014, : 1648 - 1651
  • [2] Study of the x-ray source with micro-beam
    Wang, KG
    Niu, HB
    BIOMEDICAL PHOTONICS AND OPTOELECTRONIC IMAGING, 2000, 4224 : 101 - 104
  • [3] A SIMPLE X-RAY MICRO-BEAM TECHNIQUE
    SPARK, LC
    NATURE, 1953, 171 (4355) : 695 - 695
  • [4] High energy transmission micro-beam Laue synchrotron X-ray diffraction
    Hofmann, F.
    Song, X.
    Jun, T. -S.
    Abbey, B.
    Peel, M.
    Daniels, J.
    Honkimaeki, V.
    Korsunsky, A. M.
    MATERIALS LETTERS, 2010, 64 (11) : 1302 - 1305
  • [5] Direct microfabrication using an X-ray micro-beam
    Katoh, T
    Zhang, YP
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 1578 - 1581
  • [6] Direct microfabrication using an X-ray micro-beam
    Katoh, T
    Zhang, YP
    Kagoshima, Y
    Tsusaka, Y
    Matsui, J
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 97-8 : 725 - 728
  • [7] Structural analysis of cell membrane complex of a hair fibre by micro-beam X-ray diffraction
    Ohta, N
    Oka, T
    Inoue, K
    Yagi, N
    Kato, S
    Hatta, I
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2005, 38 : 274 - 279
  • [8] Investigation of chemical vapour deposition diamond detectors by X-ray micro-beam induced current and X-ray micro-beam induced luminescence techniques
    Olivero, P
    Manfredotti, C
    Vittone, E
    Fizzotti, F
    Paolini, C
    Lo Giudice, A
    Barrett, R
    Tucoulou, R
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (10-11) : 1565 - 1573
  • [9] AN X-RAY MICRO-BEAM TECHNIQUE .1. COLLIMATION
    HIRSCH, PB
    KELLAR, JN
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1951, 64 (377): : 369 - 374
  • [10] Study of a new portable X-ray source with micro-beam
    Wang, KG
    Li, J
    Yang, QL
    Guo, JC
    Guo, BP
    Kuo, XM
    Zhou, JL
    Niu, HB
    2ND INTERNATIONAL CONFERENCE ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, 2006, 6149