Gait analysis for identifying parameters related to dementia in Intelligent Environments

被引:0
|
作者
Aztiria, Asier [1 ]
Ugarte, Miriam [1 ]
Izaguirre, Alberto [1 ]
机构
[1] Mondragon Univ, Elect & Comp Dept, Arrasate Mondragon, Spain
来源
NINTH INTERNATIONAL CONFERENCE ON INTELLIGENT ENVIRONMENTS (IE 2013) | 2013年
关键词
Gait analysis; accelerometer; dementia;
D O I
10.1109/IE.2013.10
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Gait analysis is one of the ways used to assess the evolution of people with dementia. People with dementia tend to become inactive, especially after changing to a different environment this becomes apparent. For that, it is necessary to monitor the user in an unobtrusive manner and develop algorithms to extract patterns of patients' movements from the data collected by different sensors. Such patterns allow experts to assess the degree of dementia behaviour in the movements of patients.
引用
收藏
页码:228 / 231
页数:4
相关论文
共 50 条
  • [31] Enhancing Intelligent Shoes with Gait Analysis: A Review on the Spatiotemporal Estimation Techniques
    Joseph, Anna M.
    Kian, Azadeh
    Begg, Rezaul
    SENSORS, 2024, 24 (24)
  • [32] Identifying gait differences between Alzheimer's disease and dementia with Lewy bodies and their associations with regional amyloid deposition
    Elasfar, Salma
    Hameed, Hajr
    Boeve, Bradley F.
    Fields, Julie A.
    Jack Jr, Clifford R.
    Kantarci, Kejal
    St Louis, Erik K.
    Lowe, Val J.
    Petersen, Ronald C.
    Ali, Farwa
    Ehgoetz Martens, Kaylena
    ALZHEIMERS & DEMENTIA, 2025, 21 (02)
  • [33] Agreement and consistency of five different clinical gait analysis systems in the assessment of spatiotemporal gait parameters
    Rudisch, Julian
    Joellenbeck, Thomas
    Vogt, Lutz
    Cordes, Thomas
    Klotzbier, Thomas Juergen
    Vogel, Oliver
    Wollesen, Bettina
    GAIT & POSTURE, 2021, 85 : 55 - 64
  • [34] Normalized gait analysis parameters are closely related to patient-reported outcome measures after total knee arthroplasty
    Julia Kirschberg
    Szymon Goralski
    Frank Layher
    Klaus Sander
    Georg Matziolis
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 711 - 717
  • [35] Normalized gait analysis parameters are closely related to patient-reported outcome measures after total knee arthroplasty
    Kirschberg, Julia
    Goralski, Szymon
    Layher, Frank
    Sander, Klaus
    Matziolis, Georg
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (05) : 711 - 717
  • [36] Responsiveness of gait analysis parameters in a cohort of 71 CMT subjects
    Lencioni, Tiziana
    Piscosquito, Giuseppe
    Rabuffetti, Marco
    Bovi, Gabriele
    Di Sipio, Enrica
    Diverio, Manuela
    Moroni, Isabella
    Padua, Luca
    Pagliano, Emanuela
    Schenone, Angelo
    Pareyson, Davide
    Ferrarin, Maurizio
    NEUROMUSCULAR DISORDERS, 2017, 27 (11) : 1029 - 1037
  • [37] Framework Utilizing Machine Learning to Facilitate Gait Analysis as an Indicator of Vascular Dementia
    Khan, Arshia
    Madden, Janna
    Snyder, Kristine
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2018, 9 (08) : 1 - 6
  • [38] The Role of Gait Speed in Dementia: A Secondary Analysis from the SABE Colombia Study
    Garcia-Cifuentes, Elkin
    Marquez, Isabel
    Vasquez, Daniel
    Aguillon, David
    Borda, Miguel G.
    Lopera, Francisco
    Cano-Gutierrez, Carlos
    DEMENTIA AND GERIATRIC COGNITIVE DISORDERS, 2021, 49 (06) : 565 - 572
  • [39] Effects of a Multicomponent Exercise Program on Spatiotemporal Gait Parameters, Risk of Falling and Physical Activity in Dementia Patients
    Perrochon, Anaick
    Tchalla, Achille E.
    Bonis, Joelle
    Perucaud, Florian
    Mandigout, Stephane
    DEMENTIA AND GERIATRIC COGNITIVE DISORDERS EXTRA, 2015, 5 (03) : 350 - 360
  • [40] Temporal Pattern Recognition for Gait Analysis Applications Using an "Intelligent Carpet" System
    Costilla-Reyes, Omar
    Scully, Patricia
    Ozanyan, Krikor B.
    2015 IEEE SENSORS, 2015, : 51 - 54