Effect of lens base curve on subjective comfort and assessment of fit with silicone hydrogel continuous wear contact lenses

被引:29
|
作者
Dumbleton, KA
Chalmers, RL
McNally, J
Bayer, S
Fonn, D
机构
[1] Ciba Vis Corp, Duluth, GA USA
[2] Univ Waterloo, Ctr Contact Lens Res, Waterloo, ON N2L 3G1, Canada
关键词
base curve; trial fitting procedures; silicone hydrogel contact lenses; subjective comfort; contact lenses; lens design;
D O I
10.1097/00006324-200210000-00008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To study the effect of base curve on subjective comfort of silicone hydrogel extended wear lenses. Methods. Ninety-five subjects were first trial fitted with 8.6-mm base curve lotrafilcon A (Focus Night & Day) lenses and then with 8.4-mm lenses only if poor subjective comfort or poor fit was present. Comfort and fit were assessed after 15 min. Subjects with discomfort or signs of poor fit were then trial fitted with 8.4-mm lenses. Results. Of 190 eyes, 74.2% were fitted with 8.6-mm lenses, and 23.7% required 8.4-mm lenses. Two (2.1%) subjects could not be fitted with either base curve. Mean steep keratometry (K) reading for eyes dispensed with 8.6-mm lenses was 43.88 D and 45.56 D for eyes dispensed in the 8.4-mm lenses (p < 0.001). Conclusions. A clinically useful criterion showing the need for 8.4-mm lenses was steep K of greater than or equal to45.50 D; 77% of these eyes required the steeper lens for good comfort and fit. Subjective discomfort with 8.6-mm lenses was also a useful signal for the need of a steeper lens; mean comfort scores for those subjects rose from 6.33 with 8.6-mm lenses to 9.44 with the 8.4-mm lenses for eyes requiring the steeper lens (p < 0.001).
引用
收藏
页码:633 / 637
页数:5
相关论文
共 24 条
  • [11] Conjunctival epithelial flaps with 18 months of silicone hydrogel contact lens wear
    Santodomingo-Rubido, Jacinto
    Wolffsohn, James
    Gilmartin, Bernard
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (01): : 35 - 38
  • [12] Ocular physiology and comfort in neophyte subjects fitted with daily disposable silicone hydrogel contact lenses
    Morgan, Philip B.
    Chamberlain, Paul
    Moody, Kurt
    Maldonado-Codina, Carole
    CONTACT LENS & ANTERIOR EYE, 2013, 36 (03): : 118 - 125
  • [13] Efficacy of Contact Lens Care Solutions in Removing Cholesterol Deposits From Silicone Hydrogel Contact Lenses
    Walther, Hendrik
    Subbaraman, Lakshman N.
    Jones, Lyndon
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2019, 45 (02): : 105 - 111
  • [14] Changes in UV-Visible Transmittance of Silicone-Hydrogel Contact Lenses Induced by Wear
    Lira, Madalena
    dos Santos Castanheira, Elisabete M.
    Santos, Livia
    Azeredo, Joana
    Yebra-Pimentel, Eva
    Real Oliveira, M. Elisabete C. D.
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (04) : 332 - 339
  • [15] Reduction in ionic permeability of a silicone hydrogel contact lenses after one month of daily wear
    Ferreira da Silva, Ana Rita
    Compan, Vicente
    Gonzalez-Meijome, Jose M.
    MATERIALS RESEARCH EXPRESS, 2015, 2 (06):
  • [16] Corneal shape changes induced by first and second generation silicone hydrogel contact lenses in daily wear
    Alba-Bueno, Francisco
    Beltran-Masgoret, Angel
    Sanjuan, Cristian
    Biarnes, Marc
    Marin, Jesus
    CONTACT LENS & ANTERIOR EYE, 2009, 32 (02): : 88 - 92
  • [17] The Effect of Surface Treatment of Silicone Hydrogel Contact Lenses on the Attachment of Acanthamoeba castellanii Trophozoites
    Beattie, Tara K.
    Tomlinson, Alan
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (06): : 316 - 319
  • [18] Risk of corneal inflammatory events with silicone hydrogel and low Dk hydrogel extended contact lens wear: A meta-analysis
    Szczotka-Flynn, Loretta
    Diaz, Mireya
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (04) : 247 - 256
  • [19] Changes in ocular physiology, tear film characteristics, and symptomatology with 18 months silicone hydrogel contact lens wear
    Santodomingo-Rubido, J
    Wolffsohn, JS
    Gilmartin, B
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (02) : 73 - 81
  • [20] Effect of Prophylactic Antibiotic Drops on Ocular Microbiota and Physiology during Silicone Hydrogel Lens Wear
    Ozkan, Jerome
    Zhu, Hua
    Gabriel, Manal
    Holden, Brien A.
    Willcox, Mark D. P.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (03) : 326 - 335