Estimating Movement Smoothness From Inertial Measurement Units

被引:41
作者
Melendez-Calderon, Alejandro [1 ,2 ,3 ]
Shirota, Camila [4 ,5 ,6 ]
Balasubramanian, Sivakumar [7 ]
机构
[1] Cereneo Adv Rehabil Inst CARINg, Vitznau, Switzerland
[2] Univ Queensland, Sch Informat Technol & Elect Engn, Biomed Engn Grp, St Lucia, Qld, Australia
[3] Northwestern Univ, Dept Phys Med & Rehabil, Chicago, IL 60611 USA
[4] Griffith Univ, Menzies Hlth Inst Queensland, Hopkins Ctr, Nathan, Qld, Australia
[5] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Zurich, Switzerland
[6] Univ Zurich, Dept Neurol, Zurich, Switzerland
[7] Christian Med Coll & Hosp, Dept Bioengn, Vellore, Tamil Nadu, India
关键词
movement smoothness; inertial measurement units; movement kinematics; assessment; jerk; SPARC; WEARABLE MOTION SENSORS; GAIT; ORIENTATION; DEVICES;
D O I
10.3389/fbioe.2020.558771
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Inertial measurement units (IMUs) are increasingly used to estimate movement quality and quantity to the infer the nature of motor behavior. The current literature contains several attempts to estimate movement smoothness using data from IMUs, many of which assume that the translational and rotational kinematics measured by IMUs can be directly used with the smoothness measures spectral arc length (SPARC) and log dimensionless jerk (LDLJ-V). However, there has been no investigation of the validity of these approaches. In this paper, we systematically evaluate the use of these measures on the kinematics measured by IMUs. We show that: (a) SPARC and LDLJ-V are valid measures of smoothness only when used with velocity; (b) SPARC and LDLJ-V applied on translational velocity reconstructed from IMU is highly error prone due to drift caused by integration of reconstruction errors; (c) SPARC can be applied directly on rotational velocities measured by a gyroscope, but LDLJ-V can be error prone. For discrete translational movements, we propose a modified version of the LDLJ-V measure, which can be applied to acceleration data (LDLJ-A). We evaluate the performance of these measures using simulated and experimental data. We demonstrate that the accuracy of LDLJ-A depends on the time profile of IMU orientation reconstruction error. Finally, we provide recommendations for how to appropriately apply these measures in practice under different scenarios, and highlight various factors to be aware of when performing smoothness analysis using IMU data.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    SENSORS, 2018, 18 (03):
  • [2] BENCHMARKING THE ACCURACY OF INERTIAL MEASUREMENT UNITS FOR ESTIMATING JOINT REACTIONS
    McGinnis, Ryan S.
    Hough, Jessandra
    Perkins, N. C.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 3B, 2014,
  • [3] Static and dynamic validation of inertial measurement units
    Taylor, Leah
    Miller, Emily
    Kaufman, Kenton R.
    GAIT & POSTURE, 2017, 57 : 80 - 84
  • [4] Method for Estimating Three-Dimensional Knee Rotations Using Two Inertial Measurement Units: Validation with a Coordinate Measurement Machine
    Vitali, Rachel V.
    Cain, Stephen M.
    McGinnis, Ryan S.
    Zaferiou, Antonia M.
    Ojeda, Lauro V.
    Davidson, Steven P.
    Perkins, Noel C.
    SENSORS, 2017, 17 (09):
  • [5] A Methodology for the Performance Evaluation of Inertial Measurement Units
    Sessa, Salvatore
    Zecca, Massimiliano
    Lin, Zhuohua
    Bartolomeo, Luca
    Ishii, Hiroyuki
    Takanishi, Atsuo
    JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2013, 71 (02) : 143 - 157
  • [6] Concurrent validation of magnetic and inertial measurement units in estimating upper body posture during gait
    Kang, Gu Eon
    Gross, M. Melissa
    MEASUREMENT, 2016, 82 : 240 - 245
  • [7] Estimation of kinematics from inertial measurement units using a combined deep learning and optimization framework
    Rapp, Eric
    Shin, Soyong
    Thomsen, Wolf
    Ferber, Reed
    Halilaj, Eni
    JOURNAL OF BIOMECHANICS, 2021, 116
  • [8] A Methodology for the Performance Evaluation of Inertial Measurement Units
    Salvatore Sessa
    Massimiliano Zecca
    Zhuohua Lin
    Luca Bartolomeo
    Hiroyuki Ishii
    Atsuo Takanishi
    Journal of Intelligent & Robotic Systems, 2013, 71 : 143 - 157
  • [9] Validity of inertial measurement units for tracking human motion: a systematic review
    Ghattas, John
    Jarvis, Danielle N.
    SPORTS BIOMECHANICS, 2021, : 1853 - 1866
  • [10] SmartWood: field-based analysis of large wood movement dynamics using inertial measurement units (IMUs)
    Spreitzer, Gabriel
    Schalko, Isabella
    Boes, Robert M.
    Weitbrecht, Volker
    ENVIRONMENTAL SCIENCES EUROPE, 2024, 36 (01)