Preoperative planning for accurate glenoid component positioning in reverse shoulder arthroplasty

被引:48
作者
Berhouet, J. [1 ,2 ]
Gulotta, L. V. [1 ,2 ]
Dines, D. M. [1 ]
Craig, E. [1 ]
Warren, R. F. [1 ]
Choi, D. [3 ]
Chen, X. [3 ]
Kontaxis, A. [2 ]
机构
[1] Hosp Special Surg, Dept Sports Med & Shoulder, 535 E 70th St, New York, NY 10021 USA
[2] Hosp Special Surg, Leon Root Motion Anal Lab, 510 E 73rd St, New York, NY 10021 USA
[3] Hosp Special Surg, Biomech Lab, 510 E 73rd St, New York, NY 10021 USA
关键词
Reverse shoulder arthroplasty; Glenoid component positioning; Accuracy; CT-assisted surgery; Preoperative planning; Patient-specific instrumentation; PATIENT-SPECIFIC INSTRUMENTATION; OPTIMIZING GLENOSPHERE POSITION; GLENOHUMERAL OSTEOARTHRITIS; PROSTHESIS; DESIGN; IMPINGEMENT; HIERARCHY; PLACEMENT; ARTHRITIS; ABDUCTION;
D O I
10.1016/j.otsr.2016.12.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Glenoid component positioning in reverse shoulder arthroplasty (RSA) is challenging. Patient-specific instrumentation (PSI) has been advocated to improve accuracy, and is based on precise preoperative planning. The purpose of this study was to determine the accuracy of glenoid component positioning when only the glenoid surface is visible, compared to when the entire scapula is visible on a 3D virtual model. Methods: CT scans of 30 arthritic shoulders were reconstructed in 3D models. Two surgeons then virtually placed a glenosphere component in the model while visualizing only the glenoid surface, in order to simulate typical intraoperative exposure ("blind 3D" surgery). One surgeon then placed the component in an ideal position while visualizing the entire scapula ("visible 3D" surgery). These two positions were then compared, and the accuracy of glenoid component positioning was assessed in terms of correction of native glenoid version and tilt, and avoidance of glenoid vault perforation. Results: Mean version and tilt after "blind 3D" surgery were +1.4 degrees (SD 8.8 degrees) and +7.6 degrees (SD 6 degrees), respectively; glenoid vault perforation occurred in 17 specimens. Mean version and tilt after "visible 3D" surgery were +0.3 degrees (SD 0.8 degrees) and +0.1 degrees (SD 0.5 degrees), respectively, with glenoid vault perforation in 6 cases. "Visible 3D" surgery provided significantly better accuracy than "blind 3D" surgery (P < 0.05). Conclusion: When the entire scapula is used as reference, accuracy is improved and glenoid vault perforation is less frequent. This type of visualization is only possible with pre-operative 3D CT planning, and may be augmented by PSI. (C) 2017 Published by Elsevier Masson SAS.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 37 条
[1]   Influence of glenoid component design and humeral component retroversion on internal and external rotation in reverse shoulder arthroplasty: A cadaver study [J].
Berhouet, J. ;
Garaud, P. ;
Favard, L. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (08) :887-894
[2]   Evaluation of the role of glenosphere design and humeral component retroversion in avoiding scapular notching during reverse shoulder arthroplasty [J].
Berhouet, Julien ;
Garaud, Pascal ;
Favard, Luc .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (02) :151-158
[3]  
BOILEAU P, 2005, J SHOULDER ELB SU S, V14, P147, DOI DOI 10.1016/J.JSE.2004.10.006
[4]   Bony Increased-offset Reversed Shoulder Arthroplasty: Minimizing Scapular Impingement While Maximizing Glenoid Fixation [J].
Boileau, Pascal ;
Moineau, Gregory ;
Roussanne, Yannick ;
O'Shea, Kieran .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (09) :2558-2567
[5]  
Boulahia A, 2002, ORTHOPEDICS, V25, P129
[6]   The Use of Patient-Specific Instrumentation Improves the Accuracy of Acetabular Component Placement [J].
Buller, Leonard ;
Smith, Travis ;
Bryan, Jason ;
Klika, Alison ;
Barsoum, Wael ;
Iannotti, Joseph P. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (04) :631-636
[7]   Early dislocation after reverse total shoulder arthroplasty [J].
Chalmers, Peter N. ;
Rahman, Zain ;
Romeo, Anthony A. ;
Nicholson, Gregory P. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (05) :737-744
[8]   Glenoid resurfacing: What are the limits to asymmetric reaming for posterior erosion? [J].
Clavert, Philippe ;
Millett, Peter J. ;
Warner, Jon J. P. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (06) :843-848
[9]   Current concepts in the surgical management of primary glenohumeral arthritis with a biconcave glenoid [J].
Denard, Patrick J. ;
Walch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (11) :1589-1598
[10]   Inferior tilt of the glenoid component does not decrease scapular notching in reverse shoulder arthroplasty: results of a prospective randomized study [J].
Edwards, T. Bradley ;
Trappey, George J. ;
Riley, Clayton ;
O'Connor, Daniel P. ;
Elkousy, Hussein A. ;
Gartsman, Gary M. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (05) :641-646