Efficiency of autologous stem cell collection: Comparison of three different cell separators

被引:8
|
作者
Deneys, Veronique [1 ,3 ]
Fabry, Annick [1 ]
Van Hooydonk, Maryse [1 ]
Sonet, Anne [2 ]
Andre, Marc [2 ]
Bourgeois, Marc [2 ]
Botson, Francoise [1 ]
机构
[1] CHU UCL Namur, Blood Transfus Serv Mont Godinne, Ave Dr Gaston Therasse 1, B-5530 Yvoir, Belgium
[2] CHU UCL Namur, Haematol Serv, Yvoir, Belgium
[3] CHU UCL Namur, Transfus Lab Med, Yvoir, Belgium
关键词
Apheresis; Stem cell collection; Validation; APHERESIS SYSTEMS; TRANSPLANTATION; LEUKAPHERESIS; VALIDATION; PRODUCT;
D O I
10.1016/j.transci.2016.12.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peripheral blood progenitor cells (PBPC) infusion allows rapid haematological recovery after high dose chemotherapy. Efficient PBPC collection is therefore essential as rescue therapy for transplantation. In order to validate a new equipment (ComTec((R)), Fresenius Kabi), we compared the efficiency of three cell separators for PBPC collection in patients with haematological malignant diseases. From June 2014 to December 2015, 83 PBPC were collected in 48 patients. Three aphaeresis machines were used: Cobe Spectra((R)) (Terumo BCT, 11), Amicus((R)) (Fenwall, 30), and ComTec((R)) (Fresenius Kabi, 42). The median collection efficiency was similar between the three separators. The evaluation of cell contamination in the final product revealed a lower red cell contamination with Spectra((R)) and ComTec((R)), whereas the platelet contamination was lower with Amicus((R)). The new equipment has been validated and can be further used in routine, with a total running cost that turned out to be quite lower. Each separator has its own characteristics and advantages. Further study is needed to suggest that the choice of separator could be guided following the patient's blood characteristics. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:35 / 38
页数:4
相关论文
共 50 条
  • [21] VALIDATION OF AN APPLICABLE PREDICTION MODEL BASED ON COLLECTION EFFICIENCY (CE2) FOR PERIPHERAL BLOOD STEM CELL COLLECTION IN CANDIDATES FOR AUTOLOGOUS HEMATOPOIETIC STEM CELL TRANSPLANTATION
    de Felipe Noguerales, Blanca
    Tenorio Nunez, Maria Concepcion
    Velazquez Kennedy, Kyra
    Jimenez Martin, Ana
    Valles Carboneras, Ana
    Palomo Rumschisky, Pablo
    Bolea Jarreta, Lucia
    Gonzalez Rodriguez, Alberto
    Astibia Mahillo, Beatriz
    Lopez Jimenez, Javier
    Moreno Jimenez, Gemma
    BONE MARROW TRANSPLANTATION, 2023, 58 (SUPP1) : 146 - 147
  • [22] White cell reduction during plateletpheresis:: a comparison of three blood cell separators
    Moog, R
    Müller, N
    TRANSFUSION, 1999, 39 (06) : 572 - 577
  • [23] Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
    Lee, Se-Na
    Sohn, Ji Yeon
    Kong, Jung Hee
    Eom, Hyeon Seok
    Lee, Hyewon
    Kong, Sun-Young
    ANNALS OF LABORATORY MEDICINE, 2017, 37 (04) : 327 - 330
  • [24] AN INNOVATIVE APPROACH TO AUTOLOGOUS STEM CELL COLLECTION IN THE PEDIATRIC PATIENT
    Peltz, A. C.
    Law, D. E.
    Giller, R. H.
    BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2012, 18 (02) : S257 - S257
  • [25] HOW OPTIMIZING EFFICIENCY FOR AUTOLOGOUS STEM CELL COLLECTION CAN SET THE STAGE FOR NOVEL CELL THERAPY GROWTH IN MULTIPLE DEPARTMENTS
    Stasko, K.
    Close, S.
    King, B.
    Geary, J.
    Garrity, H.
    Schott, D.
    Bagley, J.
    Crown, D.
    Ellis, M.
    Sturtevant, O. J.
    Emmert, A. E.
    Ritz, J.
    Nikiforow, S.
    CYTOTHERAPY, 2018, 20 (05) : S73 - S74
  • [26] A new protocol for improving efficiency of autologous peripheral blood stem cell collection in patients with high white blood cell counts
    Boehlen, Rahel
    Fernandez, Paula
    Bargetzi, Mario
    Sigle, Joerg-Peter
    JOURNAL OF CLINICAL APHERESIS, 2020, 35 (03) : 217 - 223
  • [27] Comparison of two blood cell separators in collecting peripheral blood stem cell components
    Stroncek, DF
    Clay, ME
    Smith, J
    Jaszcz, WB
    Herr, G
    McCullough, J
    TRANSFUSION MEDICINE, 1997, 7 (02) : 95 - 99
  • [28] The Role of Ferritin and Folate in Determining Stem Cell Collection for Autologous Stem Cell Transplant in Multiple Myeloma
    Weeks, Charles J.
    Mian, Mohammad
    Stokes, Michael
    Gold, Matthew
    Shah, Anvay
    Vuppala, Rohan
    Kim, Katherine J.
    Simon, Abigayle B.
    Cortes, Jorge
    Jillela, Anand
    Kota, Vamsi
    HEMATOLOGY REPORTS, 2025, 17 (01)
  • [29] Role of large unstained cells in predicting successful stem cell collection in autologous stem cell transplantation
    Merter, Mustafa
    Sahin, Ugur
    Uysal, Serhat
    Dalva, Klara
    Yuksel, Meltem Kurt
    TRANSFUSION AND APHERESIS SCIENCE, 2023, 62 (01)
  • [30] CD34+ Collection Efficiency as a Function of Blood Volumes Processed in Pediatric Autologous Peripheral Blood Stem Cell Collection
    Dubrovsky, Leonid
    Wong, Edward C. C.
    Perez-Albuerne, Evelio
    Loechelt, Brett
    Kamani, Naynesh
    Sande, Jane
    Mintz, Kathy
    Paul, Wendy
    Luban, Naomi L. C.
    Rood, Brian R.
    Fry, Terry
    JOURNAL OF CLINICAL APHERESIS, 2011, 26 (03) : 131 - 137