Methods of Blood Oxygen Level-Dependent Magnetic Resonance Imaging Analysis for Evaluating Renal Oxygenation

被引:32
作者
Chen, Fen [1 ]
Li, Shulin [1 ,2 ]
Sun, Dong [1 ,2 ]
机构
[1] Xuzhou Med Univ, Dept Nephrol, Xuzhou, Jiangsu, Peoples R China
[2] Xuzhou Med Univ, Affiliated Hosp, Dept Nephrol, 99 West Huai Hai Rd, Xuzhou 221002, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Blood oxygen level-dependent; Magnetic resonance imaging; Kidney; Oxygen; Hypoxia; Methods; CHRONIC KIDNEY-DISEASE; UNILATERAL URETERAL OBSTRUCTION; HUMAN RENOVASCULAR DISEASE; RENIN-ANGIOTENSIN SYSTEM; BOLD-MRI; INTRARENAL OXYGENATION; TISSUE OXYGENATION; ARTERY STENOSIS; NONINVASIVE EVALUATION; HYPERTENSIVE PATIENTS;
D O I
10.1159/000488072
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI) has recently been utilized as a noninvasive tool for evaluating renal oxygenation. Several methods have been proposed for analyzing BOLD images. Regional ROI selection is the earliest and most widely used method for BOLD analysis. In the last 20 years, many investigators have used this method to evaluate cortical and medullary oxygenation in patients with ischemic nephropathy, hypertensive nephropathy, diabetic nephropathy, chronic kidney disease (CKD), acute kidney injury and renal allograft rejection. However, clinical trials of BOLD MRI using regional ROI selection revealed that it was difficult to distinguish the renal cortico-medullary zones with this method, and that it was susceptible to observer variability. To overcome these deficiencies, several new methods were proposed for analyzing BOLD images, including the compartmental approach, fractional hypoxia method, concentric objects (CO) method and twelve-layer concentric objects (TLCO) method. The compartmental approach provides an algorithm to judge whether the pixel belongs to the cortex or medulla. Fractional kidney hypoxia, measured by using BOLD MRI, was negatively correlated with renal blood flow, tissue perfusion and glomerular filtration rate (GFR) in patients with atherosclerotic renal artery stenosis. The CO method divides the renal parenchyma into six or twelve layers of thickness in each coronal slice of BOLD images and provides a R2* radial profile curve. The slope of the R2* curve associated positively with eGFR in CKD patients. Indeed, each method invariably has advantages and disadvantages, and there is generally no consensus method so far. Undoubtedly, analytic approaches for BOLD MRI with better reproducibility would assist clinicians in monitoring the degree of kidney hypoxia and thus facilitating timely reversal of tissue hypoxia. (C) 2018 The Author(s) Published by S. Karger AG, Basel.
引用
收藏
页码:378 / 388
页数:11
相关论文
共 81 条
[11]   Blood Oxygen Level-Dependent (BOLD) MRI in Renovascular Hypertension [J].
Gloviczki, Monika L. ;
Lerman, Lilach O. ;
Textor, Stephen C. .
CURRENT HYPERTENSION REPORTS, 2011, 13 (05) :370-377
[12]   Preserved Oxygenation Despite Reduced Blood Flow in Poststenotic Kidneys in Human Atherosclerotic Renal Artery Stenosis [J].
Gloviczki, Monika L. ;
Glockner, James F. ;
Lerman, Lilach O. ;
McKusick, Michael A. ;
Misra, Sanjay ;
Grande, Joseph P. ;
Textor, Stephen C. .
HYPERTENSION, 2010, 55 (04) :961-966
[13]   Comparison of 1.5 and 3 T BOLD MR to Study Oxygenation of Kidney Cortex and Medulla in Human Renovascular Disease [J].
Gloviczki, Monika L. ;
Glockner, James ;
Gomez, Sabas I. ;
Romero, Juan C. ;
Lerman, Lilach O. ;
McKusick, Michael ;
Textor, Stephen C. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (09) :566-571
[14]   Mechanisms of Hypoxia Responses in Renal Tissue [J].
Haase, Volker H. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2013, 24 (04) :537-541
[15]   Beta-Blocker Use Is Associated with Higher Renal Tissue Oxygenation in Hypertensive Patients Suspected of Renal Artery Stenosis [J].
Hall, Michael E. ;
Rocco, Michael V. ;
Morgan, Timothy M. ;
Hamilton, Craig A. ;
Jordan, Jennifer H. ;
Edwards, Matthew S. ;
Hall, John E. ;
Hundley, William G. .
CARDIORENAL MEDICINE, 2016, 6 (04) :261-268
[16]   Chronic diuretic therapy attenuates renal BOLD magnetic resonance response to an acute furosemide stimulus [J].
Hall, Michael E. ;
Rocco, Michael V. ;
Morgan, Timothy M. ;
Hamilton, Craig A. ;
Edwards, Matthew S. ;
Jordan, Jennifer H. ;
Hurie, Justin B. ;
Hundley, W. Gregory .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
[17]   Renal parenchymal hypoxia, hypoxia response and the progression of chronic kidney disease [J].
Heyman, Samuel N. ;
Khamaisi, Mogher ;
Rosen, Seymour ;
Rosenberger, Christian .
AMERICAN JOURNAL OF NEPHROLOGY, 2008, 28 (06) :998-1006
[18]   Renal Hypoxia in CKD; Pathophysiology and Detecting Methods [J].
Hirakawa, Yosuke ;
Tanaka, Tetsuhiro ;
Nangaku, Masaomi .
FRONTIERS IN PHYSIOLOGY, 2017, 8
[19]   Is there no future for renal BOLD-MRI? [J].
Inoue, Tsutomu ;
Kozawa, Eito ;
Okada, Hirokazu ;
Suzuki, Hiromichi .
KIDNEY INTERNATIONAL, 2012, 82 (08) :934-934
[20]   Noninvasive Evaluation of Kidney Hypoxia and Fibrosis Using Magnetic Resonance Imaging [J].
Inoue, Tsutomu ;
Kozawa, Eito ;
Okada, Hirokazu ;
Inukai, Kouichi ;
Watanabe, Shinichi ;
Kikuta, Tomohiro ;
Watanabe, Yusuke ;
Takenaka, Tsuneo ;
Katayama, Shigehiro ;
Tanaka, Junji ;
Suzuki, Hiromichi .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2011, 22 (08) :1429-1434