Digital volume tomography in the diagnosis of peri-implant defects: An in vitro study on native pig mandibles

被引:71
作者
Mengel, Reiner [1 ]
Kruse, Bjoern [1 ]
Flores-de-Jacoby, Lavin [1 ]
机构
[1] Univ Marburg, Sch Dent, Dept Periodontol, D-35033 Marburg, Germany
关键词
animal studies; computed tomography; defects; dental implants; diagnosis; COMPUTED-TOMOGRAPHY; CLINICAL-APPLICATION; CT; TISSUES; SYSTEM;
D O I
10.1902/jop.2006.050424
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The aim of this study of native pig mandibles was to investigate the accuracy and quality of the representation of peri-implant defects by intraoral radiography (IR), panoramic radiography (PR), computer tomography (CT), and digital volume tomography (DVT). Methods: The examination was carried out on 19 native pig mandibles. In the toothless sections of the mandibles, one or two implants were inserted. Following the standardized preparation of peri-implant defects (11 each of dehiscences, fenestrations, and 2- to 3-walled intrabony defects), IR, PR, CT, and DVT were performed. The peri-implant defects were measured using appropriate software on the digitized IR and PR image programs. As a control method, the peri-implant bone defects were measured directly using a reflecting stereomicroscope with measuring ocular. The statistical comparison between the measurements of the radiographic scans and those of the direct readings of the peri-implant defects was performed with Pearson's correlation coefficient. The quality of the radiographic scans was determined through the subjective perception and detectability of the peri-implant defects by five independent observers. Results: In the DVT and CT scans, it was possible to measure all the bone defects in three planes. Comparison with the direct peri-implant defect measurements yielded a mean deviation of 0.17 +/- 0.11 mm for the DVT scans and 0.18 +/- 0.12 mm for the CT scans. On the IR and PR images, the defects could be detected only in the mesio-distal and cranio-caudal planes. In comparison with the direct measurements of the peri-implant defects, the IR images revealed a mean deviation of 0.34 +/- 0.30 mm, and the PR images revealed a mean deviation of 0.41 +/- 0.35 mm. The quality rating of the radiographic images was highest for the DVT scans. Conclusions: Overall, the CT and DVT scans displayed only a slight deviation in the extent of the peri-implant defects. Both radiographic imaging techniques permitted imaging of peri-implant defects in three planes, true to scale, and without overlay or distortion. The DVT scans showed the best imaging quality.
引用
收藏
页码:1234 / 1241
页数:8
相关论文
共 31 条
[1]   CT-SCANNING IN THE PREOPERATIVE PLANNING OF OSSEOINTEGRATED IMPLANTS IN THE MAXILLA [J].
ANDERSSON, JE ;
SVARTZ, K .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 17 (01) :33-35
[2]  
Arai Y, 2001, INT CONGR SER, V1230, P671
[3]  
Berglundh T, 1992, Clin Oral Implants Res, V3, P1, DOI 10.1034/j.1600-0501.1992.030101.x
[4]  
CASSELMAN JW, 1988, J HEAD NECK PATHOL, V7, P255
[5]  
Dula K, 1994, Schweiz Monatsschr Zahnmed, V104, P450
[6]  
ERICSON S, 1988, EUR J ORTHODONT, V10, P115
[7]  
FLORESDEJACOBY L, 1997, DTSCH ZAHNARZTL Z, V52, P728
[8]  
Fuhrmann R., 1997, Dtsch Zahnarztl Z, V52, P112
[9]   ASSESSMENT OF THE DENTATE ALVEOLAR PROCESS WITH HIGH-RESOLUTION COMPUTED-TOMOGRAPHY [J].
FUHRMANN, RAW ;
WEHRBEIN, H ;
LANGEN, HJ ;
DIEDRICH, PR .
DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (01) :50-54
[10]   MICROBIOLOGIC CHARACTERIZATION OF LIGATURE-INDUCED PERI-IMPLANTITIS IN THE MICROSWINE MODEL [J].
HICKEY, JS ;
ONEAL, RB ;
SCHEIDT, MJ ;
STRONG, SL ;
TURGEON, D ;
VANDYKE, TE .
JOURNAL OF PERIODONTOLOGY, 1991, 62 (09) :548-553