Contrast-enhanced color Doppler ultrasonography increases diagnostic accuracy for soft tissue tumors

被引:30
|
作者
Oebisu, Naoto [1 ]
Hoshi, Manabu [1 ]
Ieguchi, Makoto [1 ]
Takada, Jun [1 ]
Iwai, Tadashi [1 ]
Ohsawa, Masahiko [2 ]
Nakamura, Hiroaki [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Orthoped Surg, Abeno Ku, Osaka 5458585, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Diagnost Pathol, Abeno Ku, Osaka 5458585, Japan
关键词
contrast-enhanced ultrasonography; soft tissue tumor; vascularity; sonazoid; MUSCULOSKELETAL TUMORS; MASSES; DIFFERENTIATION; SONOGRAPHY; BENIGN; ULTRASOUND; EXTREMITY; SPECTRUM; SARCOMA; LESIONS;
D O I
10.3892/or.2014.3378
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Resolution of ultrasonography (US) has undergone marked development. Additionally, a new-generation contrast medium (Sonazoid) used for US is newly available. Contrast-enhanced US has been widely used for evaluating several types of cancer. In the present study, we evaluated the ability of color Doppler US (CDUS) and Sonazoid to differentiate between benign and malignant soft tissue tumors. A total of 180 patients (87 male, 93 female) were enrolled in the present study. The patient ages ranged from 1 to 91 years (mean 58.1 +/- 20.0 years). The maximum size, depth, tumor margins, shape, echogenicity and textural pattern were measured on gray-scale images. CDUS was used to evaluate the intratumoral blood flow with and without Sonazoid. Peak systolic flow velocity (Vp), mean flow velocity (Vm), resistivity index (RI) and pulsatility index (PI) of each detected intratumoral artery were automatically calculated with power Doppler US (PDUS). The present study included 118 benign and 62 malignant tumors. Statistical significances were found in size, depth, tumor margin and textural pattern but not in shape or echogenicity on gray-scale images. Before Sonazoid injection, CDUS findings showed 55% sensitivity, 77% specificity and 69% accuracy, whereas contrast-enhanced CDUS showed 87% sensitivity, 68% specificity and 74% accuracy. There were no statistically significant differences between malignant and benign tumors regarding the mean Vp, Vm, RI and PI values determined on PDUS. In conclusion, contrast-enhanced CDUS proved to be a reliable diagnostic tool for detecting malignant potential in soft tissue tumors.
引用
收藏
页码:1654 / 1660
页数:7
相关论文
共 50 条
  • [21] Neuroendocrine Tumors: Characterization with Contrast-Enhanced Ultrasonography
    Doerffel, Y.
    Wermke, W.
    ULTRASCHALL IN DER MEDIZIN, 2008, 29 (05): : 506 - 514
  • [22] Value of Contrast-Enhanced Ultrasonography in Assessing the Vascularity of Liver Metastases Comparison With Contrast-Enhanced Computed Tomography
    Zheng, Yan-Ling
    Yin, Xiao-Yu
    Xie, Xiao-Yan
    Xu, Hui-Xiong
    Xu, Zuo-Feng
    Liu, Guang-Jian
    Liang, Jin-Yu
    Lu, Ming-De
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (10) : 1403 - 1410
  • [23] Contrast-Enhanced Color Doppler Ultrasonography for Preoperative Evaluation of Sentinel Lymph Node in Breast Cancer Patients
    Dellaportas, Dionysios
    Koureas, Andreas
    Contis, John
    Lykoudis, Panagis M.
    Vraka, Irene
    Psychogios, Dimitrios
    Kondi-Pafiti, Agatha
    Voros, Dionysios K.
    BREAST CARE, 2015, 10 (05) : 331 - 335
  • [24] Contrast-Enhanced Endoscopic Ultrasonography for Pancreatic Tumors
    Yamashita, Yasunobu
    Kato, Jun
    Ueda, Kazuki
    Nakamura, Yasushi
    Kawaji, Yuki
    Abe, Hiroko
    Nuta, Junya
    Tamura, Takashi
    Itonaga, Masahiro
    Yoshida, Takeichi
    Maeda, Hiroki
    Maekita, Takao
    Iguchi, Mikitaka
    Tamai, Hideyuki
    Ichinose, Masao
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [25] Contrast-Enhanced Ultrasonography in Pancreas Transplantation
    Kersting, Stephan
    Ludwig, Stefan
    Ehehalt, Florian
    Volk, Andreas
    Bunk, Alfred
    TRANSPLANTATION, 2013, 95 (01) : 209 - 214
  • [26] Contrast-enhanced ultrasonography of testicular tumours
    Lock, G.
    UROLOGE, 2019, 58 (12): : 1410 - 1417
  • [27] Comparative diagnostic value of computed tomography and contrast-enhanced ultrasonography in diagnosis of focal liver lesions
    Zviniene, Kristina
    Zaboriene, Inga
    Basevicius, Algidas
    Pundzius, Juozas
    MEDICINA-LITHUANIA, 2009, 45 (10): : 751 - 763
  • [28] Contrast-enhanced ultrasonography using SonazoidA® is useful for diagnosis of malignant ovarian tumors: comparison with Doppler ultrasound
    Kumazawa, Shoko
    Umezu, Tomokazu
    Kanayama, Yuko
    Kamiyama, Naohisa
    Suzuki, Shiro
    Mizuno, Mika
    Kajiyama, Hiroaki
    Shibata, Kiyosumi
    Kikkawa, Fumitaka
    JOURNAL OF MEDICAL ULTRASONICS, 2013, 40 (01) : 81 - 84
  • [29] Evaluation of renal urothelial carcinoma by contrast-enhanced ultrasonography
    Xue, Li-Yun
    Lu, Qing
    Huang, Bei-Jian
    Li, Chao-Lun
    Yan, Cui-Ju
    Wen, Jie-Xian
    Wang, Wen-Ping
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : E151 - E157
  • [30] Preoperatively determining the margins of subcutaneous malignant soft tissue tumours using contrast-enhanced ultrasonography
    Oguro, Sota
    Kikuta, Kazutaka
    Sasaki, Aya
    Okuma, Kiyoshi
    Matsumoto, Shunsuke
    Sugiura, Hiroaki
    Morioka, Hideo
    Nakamura, Masaya
    Matsumoto, Morio
    Jinzaki, Masahiro
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (02) : 385 - 388