Novel single-wall carbon nanotube screen-printed electrode as an immunosensor for human chorionic gonadotropin

被引:25
作者
Teixeira, Sofia [1 ]
Conlan, Robert Steven [2 ]
Guy, O. J. [1 ]
Sales, M. Goreti F. [3 ]
机构
[1] Swansea Univ, Coll Engn, Swansea, W Glam, Wales
[2] Swansea Univ, Coll Med, Swansea, W Glam, Wales
[3] BioMark, ISEP, Sch Engn, Polytech Inst Porto, P-4200072 Oporto, Portugal
基金
英国工程与自然科学研究理事会;
关键词
Immunosensor; Screen-printed electrode; CNT; APTES; Human chorionic gonadotropin; TERMINATED ORGANIC FILMS; SILICON-OXIDE SURFACES; ATMOSPHERIC-PRESSURE; IMMOBILIZATION; BIOSENSOR; FUNCTIONALIZATION; ATTACHMENT; ANTIBODIES; CHEMISTRY; SITES;
D O I
10.1016/j.electacta.2014.05.105
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy. A sensor device for detection of hCG has been fabricated using a CNT (carbon nanotube) screen printed electrode (SPE). The CNT working electrode was first electrochemically oxidised to yield a hydroxyl terminated surface, which was subsequently silanized to produce an amine terminated CNT. The aminated surface allowed oriented binding of an antibody (Ab) bioreceptor, targeted against hCG (anti-hCG), to the CNT-SPE. This was achieved by activating the -COOH group at the F-c terminal of the antibody and incubating the SPE-CNT-NH2 electrode in the activated Ab solution. Electrochemical Impedance Spectroscopy (EIS) and Raman Spectrometry with Confocal Microscopy studies were performed at each stage of the chemical modification process in order to confirm the resulting surface changes associated with each functionalization process. The SPE-CNT-NH2-Ab devices displayed linear responses to hCG in EIS assays in the concentration range from 0.01 x 10(-9) g cm(-3) to 100 x 10(-9) g cm(-3). High specificity was observed with respect to hCG detected in solutions containing urine components-these components producing a negligible change in the sensor readout relative to changes induced by hCG. Successful hCG detection was also achieved using real urine samples from pregnant woman. Overall, the immunosensor developed is a promising tool for detecting hCG in a point-of-care diagnostic (POC), due to the excellent detection capability, simplicity of fabrication, low cost, high sensitivity and selectivity. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 46 条
  • [21] Atmospheric-Pressure Plasma Amination of Polymer Surfaces
    Klages, Claus-Peter
    Hinze, Alena
    Willich, Peter
    Thomas, Michael
    [J]. JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2010, 24 (06) : 1167 - 1180
  • [22] Infrared Characterization of Biotinylated Silicon Oxide Surfaces, Surface Stability, and Specific Attachment of Streptavidin
    Lapin, Norman A.
    Chabal, Yves J.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2009, 113 (25) : 8776 - 8783
  • [23] Ultrasensitive electrochemical immunosensor based on Au nanoparticles dotted carbon nanotube-graphene composite and functionalized mesoporous materials
    Lu, Juanjuan
    Liu, Shiquan
    Ge, Shenguang
    Yan, Mei
    Yu, Jinghua
    Hu, Xiutao
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 33 (01) : 29 - 35
  • [24] Biomaterial with chemically engineered surface for protein immobilization
    Mansur, HS
    Oréfice, RL
    Vasconcelos, WL
    Lobato, ZP
    Machado, LJC
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2005, 16 (04) : 333 - 340
  • [25] Surface functionalization of porous glass networks: Effects on bovine serum albumin and porcine insulin immobilization
    Mansur, HS
    Lobato, ZP
    Orefice, RL
    Vasconcelos, WL
    Oliveira, C
    Machado, LJ
    [J]. BIOMACROMOLECULES, 2000, 1 (04) : 789 - 797
  • [26] Merkoci A., 2005, TRENDS ANAL CHEM, V24, P24
  • [27] Modification of silk fibroin using diazonium coupling chemistry and the effects on hMSC proliferation and differentiation
    Murphy, Amanda R.
    John, Peter St.
    Kaplan, David L.
    [J]. BIOMATERIALS, 2008, 29 (19) : 2829 - 2838
  • [28] Impedimetric Biosensor for the Assessment of the Clotting Activity of Rennet
    Panagopoulou, Maria A.
    Stergiou, Dimitrios V.
    Roussis, Ioannis G.
    Prodromidis, Mamas I.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (20) : 8629 - 8636
  • [29] Attachment of 3-(Aminopropyl)triethoxysilane on Silicon Oxide Surfaces: Dependence on Solution Temperature
    Pasternack, Robert M.
    Amy, Sandrine Rivillon
    Chabal, Yves J.
    [J]. LANGMUIR, 2008, 24 (22) : 12963 - 12971
  • [30] Carbon nanotubes for electrochemical biosensing
    Rivas, Gustavo A.
    Rubianes, Maria D.
    Rodriguez, Marcela C.
    Ferreyra, Nancy E.
    Luque, Guillermina L.
    Pedano, Maria L.
    Miscoria, Silvia A.
    Parrado, Concepcion
    [J]. TALANTA, 2007, 74 (03) : 291 - 307