Preoperative autologous donation for total joint arthroplasty - An analysis of risk factors for allogenic transfusion

被引:91
作者
Hatzidakis, AM
Mendlick, RM
McKillip, T
Reddy, RL
Garvin, KL
机构
[1] Univ Nebraska, Med Ctr, Dept Orthopaed, Omaha, NE 68198 USA
[2] Omaha Vet Adm Med Ctr, Omaha, NE 68198 USA
关键词
D O I
10.2106/00004623-200001000-00011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background While autologous blood is commonly predonated to provide replacement of blood lost in orthopaedic procedures, few studies of patients managed with total joint replacement have addressed the problem of which patients are likely to benefit from an autologous blood-donation program. Methods: A retrospective analysis of 489 consecutive patients who had had a total joint arthroplasty was performed to identify the risk factors for allogenic transfusion and to further define the indications for preoperative autologous blood donation. The operations included 247 total knee replacements (157 unilateral primary, thirty-two revision, and twenty-nine one-stage bilateral primary procedures) and 271 total hip replacements (163 primary and 108 revision procedures). Fifty-four percent (264) of the 489 patients donated a total of 527 units of blood (average, 2.0 units per patient) preoperatively, Results: One hundred and ninety-one patients (39 percent) required a transfusion of autologous blood or allogenic blood, or both. One hundred and thirty-one patients (27 percent) received autologous blood, and eighty-two patients (17 percent) received a transfusion of allogenic blood; twenty-two patients (4 percent) received both autologous and allogenic blood. Neither form of transfusion caused serious complications. Fifty-six percent (295) of the 527 units of autologous blood were discarded. Autologous donation significantly decreased the requirements for allogenic transfusion (relative risk, 0.1; p < 0.0001), It also caused the level of hemoglobin to decrease an average of 12.2 grams per lifer from the time before donation to the time before the operation (p < 0.0001). Factors that increased the risk for allogenic transfusion were a revision knee or hip procedure or a one-stage bilateral primary knee replacement (relative risk, 5.7; p < 0.0001), an initial hemoglobin level of less than 130 grams per liter (relative risk, 5.6; p < 0.0001), and an age of sixty-five years or older (relative risk, 2.8; p = 0.02), None of the sixty-seven patients who had a primary knee or hip arthroplasty and an initial hemoglobin level of 150 grams per liter or more required an allogenic transfusion, In addition, none of the sixty-three patients who had a primary arthroplasty, an initial hemoglobin level of between 130 and less than 150 grams per lifer, and an age of less than sixty-five years required an allogenic transfusion. Eighty-three percent (115) of the 138 autologous units donated by the seventy patients in these two groups were discarded. These wasted units accounted for 39 percent of the 295 discarded units for the entire study sample, Conclusions: The efficiency of collection of autologous blood can be improved by identifying patients who have a very low risk of transfusion according to the type of arthroplasty, the initial level of hemoglobin, and age. patients who have an initial hemoglobin level of at least 150 grams per lifer or an initial hemoglobin level of between 130 and 150 grams per lifer and an age of less than sixty-five years have a minimal risk of needing a transfusion during or after a primary total joint replacement. These patients should be apprised of their low risk so that they can make an informed decision regarding preoperative autologous donation.
引用
收藏
页码:89 / 100
页数:12
相关论文
共 57 条
  • [1] Safety of the blood supply in the United States: Opportunities and controversies
    AuBuchon, JP
    Birkmeyer, JD
    Busch, MP
    [J]. ANNALS OF INTERNAL MEDICINE, 1997, 127 (10) : 904 - 909
  • [2] IS AUTOLOGOUS BLOOD-TRANSFUSION WORTH THE COST - CON
    AUBUCHON, JP
    BIRKMEYER, JD
    [J]. TRANSFUSION, 1994, 34 (01) : 79 - 83
  • [3] BLOOD SALVAGE AFTER TOTAL HIP-ARTHROPLASTY
    AYERS, DC
    MURRAY, DG
    DUERR, DM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) : 1347 - 1351
  • [4] Bernstein LH, 1997, ORTHOPEDICS, V20, P677
  • [5] BERNSTEIN MJ, 1988, JAMA-J AM MED ASSOC, V260, P2700
  • [6] An analysis of blood management in patients having a total hip or knee arthroplasty
    Bierbaum, BE
    Callaghan, JJ
    Galante, JO
    Rubash, HE
    Tooms, RE
    Welch, RB
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) : 2 - 10
  • [7] COLLECTION OF AUTOLOGOUS BLOOD BEFORE ELECTIVE HIP-REPLACEMENT - A COMPARISON OF THE RESULTS WITH THE COLLECTION OF 2 AND 4 UNITS
    BIESMA, DH
    MARX, JJM
    VANDEWIEL, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (10) : 1471 - 1475
  • [8] THE COST-EFFECTIVENESS OF PREOPERATIVE AUTOLOGOUS BLOOD DONATION FOR TOTAL HIP AND KNEE REPLACEMENT
    BIRKMEYER, JD
    GOODNOUGH, LT
    AUBUCHON, JP
    NOORDSIJ, PG
    LITTENBERG, B
    [J]. TRANSFUSION, 1993, 33 (07) : 544 - 551
  • [9] A cost analysis of autologous and allogeneic transfusions in hip-replacement surgery
    Blumberg, N
    Kirkley, SA
    Heal, JM
    [J]. AMERICAN JOURNAL OF SURGERY, 1996, 171 (03) : 324 - 330
  • [10] AUTOTRANSFUSION IN CHILDRENS ORTHOPEDICS
    COWELL, HR
    SWICKARD, JW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (05) : 908 - 912