Transportation assessment in artificial curved canals after instrumentation with Reciproc, Reciproc Blue, and XP-endo Shaper Systems

被引:17
作者
Pacheco-Yanes, Juan [1 ]
Gazzaneo, Isbelia [1 ]
Perez, Alejandro R. [1 ]
Armada, Luciana [1 ]
Neves, Monica A. S. [1 ]
机构
[1] Univ Estacio Sa, Dept Endodont, Fac Dent, Rio De Janeiro, Brazil
关键词
nickel-titanium; Reciproc; Reciproc Blue; root canal; XP-endo Shaper; SHAPING ABILITY; FATIGUE RESISTANCE; ROTARY INSTRUMENTS; TITANIUM; FILES; VORTEX; TAPER;
D O I
10.1111/jicd.12417
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim In the present study, we compared the transportation of three different instrumentation systems in different levels of standardized artificial curved canals. Methods Sixty epoxy resin blocks containing simulated canals were divided into three groups (n = 20) according to the instrument used for canal preparation: Reciproc (REC), Reciproc Blue (REC Blue), and XP-endo Shaper (XPS). Pre- and post-instrumentation digital images of each specimen were superimposed by Photoshop software to evaluate the different amount of transportation. The Kruskal-Wallis and Wilcoxon were the non-parametric tests applied for the intergroup and intragroup analyses, respectively. The significance level was set at 5%. Results The XPS showed significantly less canal transportation than REC Blue at five levels (P < 0.05) and significantly less canal transportation at seven evaluated levels when compared with the REC (P < 0.05). REC Blue showed significant less canal transportation than REC at four of the eight evaluated levels (P < 0.05). All evaluated instruments showed a significantly higher amount of resin removal toward the inner wall compared to the outer wall of the curvature (P < 0.001). Conclusion Although the XPS showed significantly less canal transportation than REC and REC Blue, all systems produced transportation from the original canal anatomy.
引用
收藏
页数:7
相关论文
共 38 条
[1]   THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL [J].
ABOURASS, M ;
FRANK, AL ;
GLICK, DH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) :792-794
[2]   Glide Path Preparation in S-shaped Canals with Rotary Pathfinding Nickel-Titanium Instruments [J].
Ajuz, Natasha C. C. ;
Armada, Luciana ;
Goncalves, Lucio S. ;
Debelian, Gilberto ;
Siqueira, Jose F., Jr. .
JOURNAL OF ENDODONTICS, 2013, 39 (04) :534-537
[3]   Evaluation of apical debris removal using various sizes and tapers of ProFile GT files [J].
Albrecht, LJ ;
Baumgartner, JC ;
Marshall, JG .
JOURNAL OF ENDODONTICS, 2004, 30 (06) :425-428
[4]  
Altunbas Demet, 2015, Eur J Dent, V9, P346, DOI 10.4103/1305-7456.163221
[5]   A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals [J].
Bishop, K ;
Dummer, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :25-34
[6]   The effect of root canal taper on the irrigant flow: evaluation using an unsteady Computational Fluid Dynamics model [J].
Boutsioukis, C. ;
Gogos, C. ;
Verhaagen, B. ;
Versluis, M. ;
Kastrinakis, E. ;
van der Sluis, L. W. M. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (10) :909-916
[7]   Shaping Ability of Different Nickel-Titanium Systems in Simulated S-shaped Canals with and without Glide Path [J].
Buerklein, Sebastian ;
Poschmann, Thomas ;
Schaefen, Edgar .
JOURNAL OF ENDODONTICS, 2014, 40 (08) :1231-1234
[8]  
Burklein S., 2013, Endodontic Topics, V29, P110, DOI [DOI 10.1111/etp.12043, DOI 10.1111/ETP.12043]
[9]  
de Sousa-Neto MD, 2018, BRAZ ORAL RES, V32, P20
[10]   Blue Thermomechanical Treatment Optimizes Fatigue Resistance and Flexibility of the Reciproc Files [J].
De-Deus, Gustavo ;
Nogueira Leal Silva, Emmanuel Joao ;
Leal Vieira, Victor Talarico ;
Belladonna, Felipe Goncalves ;
Elias, Carlos Nelson ;
Plotino, Gianluca ;
Grande, Nicola Maria .