Residence Time Distribution Analysis of a Hollow-Fiber Contactor for Membrane Gas Absorption and Vibration-Induced Mass Transfer Intensification

被引:4
|
作者
Zhang, Weidong [1 ]
Hao, Zisu [1 ]
Li, Jiang [1 ]
Liu, Junteng [1 ]
Wang, Zihao [1 ]
Ren, Zhongqi [1 ]
机构
[1] Beijing Univ Chem Technol, State Key Lab Chem Resource Engn, Beijing Key Lab Membrane Sci & Technol, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
TRANSFER PERFORMANCE; SOLVENT-EXTRACTION; LIQUID; FLOW; MODULES; POLYPROPYLENE; COLUMNS; SURFACE; MODEL;
D O I
10.1021/ie500583v
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The relationship between the flow conditions and the mass transfer in a hollow-fiber membrane contactor was quantitatively correlated by coupling a residence time distribution (RTD) method with a multicontinuous stirred tank reactor model (mCSTR). A vibration technique was applied to manipulate and intensify the mass transfer performance of the hollow-fiber contactor (HFC). Absorption behaviors of CO2 in deionized water were investigated as a model system. The effects of liquid feeding velocity, vibration direction and frequency, operating modes, and packing density on the flow conditions and mass transfer performance were investigated and quantitatively examined by the RTD analysis. The results indicated that the flow conditions as well as the mass transfer performance can be greatly improved at a low liquid-phase velocity or a high packing density. Similarly, the mass transfer intensification was more remarkable, when the absorbent flowed through the shell side of HFC, or the vibration and flow directions were vertical. The mass transfer coefficients obtained from the RTD-mCSTR model showed good agreement with those obtained from the experiments. It appeared that the vibration technique was a powerful method to improve the flow conditions and greatly enhanced the mass transfer performance.
引用
收藏
页码:8640 / 8650
页数:11
相关论文
共 50 条
  • [41] Modeling of Ethylene Absorption from an Ethylene–Ethane Mixture by Silver Nitrate Aqueous Solution in a Hollow-Fiber Membrane Contactor
    V. A. Kirsch
    V. I. Roldugin
    A. A. Ovcharova
    A. V. Bildyukevich
    Petroleum Chemistry, 2017, 57 : 1242 - 1249
  • [42] Effects of velocity distribution of dialysate on mass transfer in the shell side of a hollow-fiber dialyzer
    Yoshikawa, S
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2003, 36 (09) : 1076 - 1084
  • [43] Study of intrinsic oxygen mass transfer characteristic and model on polypropylene hollow fiber membrane contactor
    Han, Yu
    Huang, Xiao
    Lu, Yin
    Zhu, Dongfa
    Shi, Xizhi
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 121 (121)
  • [44] Teflon AF2400 Hollow Fiber Membrane Contactor for Dissolved Gas-in-Oil Extraction: Mass Transfer Characteristics
    Ma, Liang-Chih
    Chen, Chuan
    Lin, Jerry Y. S.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (38) : 16795 - 16804
  • [45] Mass transfer modelling of hollow fiber membrane contactor for apple juice concentration using osmotic membrane distillation
    Ahmad, Sher
    Marson, Gabriela Vollet
    Zeb, Waheed
    Rehman, Waheed Ur
    Younas, Mohammad
    Farrukh, Sarah
    Rezakazemi, Mashallah
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 250
  • [46] HOLLOW FIBER MEMBRANE CONTACTOR ABSORPTION OF CO2 FROM THE FLUE GAS: REVIEW AND PERSPECTIVE
    Zhang, Z. E.
    Yan, Y. F.
    Zhang, L.
    Ju, S. X.
    GLOBAL NEST JOURNAL, 2014, 16 (02): : 354 - 373
  • [47] 3D-CFD Modeling of Hollow-Fiber Membrane Contactor for CO2 Absorption Using MEA Solution
    Bozonc, Alexandru-Constantin
    Sandu, Vlad-Cristian
    Cormos, Calin-Cristian
    Cormos, Ana-Maria
    MEMBRANES, 2024, 14 (04)
  • [48] A study on vapor transport characteristics in hollow-fiber membrane humidifier with empirical mass transfer coefficient
    Vu, Hoang Nghia
    Nguyen, Xuan Linh
    Han, Jaeyoung
    Yu, Sangseok
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 177
  • [49] ENZYMATIC PEROXYCARBOXYLIC ACID FORMATION IN A HOLLOW-FIBER MEMBRANE REACTOR - KINETICS AND MASS-TRANSFER
    KRAMER, GFH
    BOUWER, ST
    VANGEMERT, RW
    DERKSEN, JTP
    CUPERUS, FP
    CATALYSIS TODAY, 1994, 22 (03) : 537 - 547
  • [50] Mass transfer performance and correlation for CO2 absorption into aqueous 3-diethylaminopropylamine solution in a hollow fiber membrane contactor
    Chen G.
    Chen G.
    Cao F.
    Zhang R.
    Gao H.
    Liang Z.
    Chemical Engineering and Processing - Process Intensification, 2020, 152