Residence Time Distribution Analysis of a Hollow-Fiber Contactor for Membrane Gas Absorption and Vibration-Induced Mass Transfer Intensification

被引:4
|
作者
Zhang, Weidong [1 ]
Hao, Zisu [1 ]
Li, Jiang [1 ]
Liu, Junteng [1 ]
Wang, Zihao [1 ]
Ren, Zhongqi [1 ]
机构
[1] Beijing Univ Chem Technol, State Key Lab Chem Resource Engn, Beijing Key Lab Membrane Sci & Technol, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
TRANSFER PERFORMANCE; SOLVENT-EXTRACTION; LIQUID; FLOW; MODULES; POLYPROPYLENE; COLUMNS; SURFACE; MODEL;
D O I
10.1021/ie500583v
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The relationship between the flow conditions and the mass transfer in a hollow-fiber membrane contactor was quantitatively correlated by coupling a residence time distribution (RTD) method with a multicontinuous stirred tank reactor model (mCSTR). A vibration technique was applied to manipulate and intensify the mass transfer performance of the hollow-fiber contactor (HFC). Absorption behaviors of CO2 in deionized water were investigated as a model system. The effects of liquid feeding velocity, vibration direction and frequency, operating modes, and packing density on the flow conditions and mass transfer performance were investigated and quantitatively examined by the RTD analysis. The results indicated that the flow conditions as well as the mass transfer performance can be greatly improved at a low liquid-phase velocity or a high packing density. Similarly, the mass transfer intensification was more remarkable, when the absorbent flowed through the shell side of HFC, or the vibration and flow directions were vertical. The mass transfer coefficients obtained from the RTD-mCSTR model showed good agreement with those obtained from the experiments. It appeared that the vibration technique was a powerful method to improve the flow conditions and greatly enhanced the mass transfer performance.
引用
收藏
页码:8640 / 8650
页数:11
相关论文
共 50 条
  • [1] Mass Transfer Simulation of Carbon Dioxide Absorption in a Hollow-Fiber Membrane Contactor
    Shirazian, S.
    Ashrafizadeh, S. N.
    SEPARATION SCIENCE AND TECHNOLOGY, 2010, 45 (04) : 515 - 524
  • [2] Effect of porosity on mass transfer of gas absorption in a hollow fiber membrane contactor
    Zhang, Weidong
    Hao, Zisu
    Chen, Geng
    Li, Jiang
    Li, Zhushi
    Wang, Zihao
    Ren, Zhongqi
    JOURNAL OF MEMBRANE SCIENCE, 2014, 470 : 399 - 410
  • [3] Two-Dimensional Conjugated Mass Transfer of Carbon Dioxide Absorption in a Hollow-Fiber Gas-Liquid Membrane Contactor
    Ho, Chii-Dong
    Chen, Luke
    Huang, Chien-Chang
    Chen, Chien-Hua
    Chew, Thiam Leng
    Chen, Yu-Han
    MEMBRANES, 2022, 12 (10)
  • [4] Gas absorption in a hollow-fiber membrane contactor with pseudo-plastic liquid as an absorbent
    Todorovic, Julijana
    Krstic, Darko M.
    Vatai, Gyula N.
    Tekic, Miodrag N.
    DESALINATION, 2006, 193 (1-3) : 286 - 290
  • [5] MASS TRANSFER ANALYSIS AND SIMULATION OF A HOLLOW FIBER GAS-LIQUID MEMBRANE CONTACTOR
    Keshavarz, P.
    Fathikalajahi, J.
    Ayatollahi, S.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION B-ENGINEERING, 2008, 32 (B6): : 585 - 599
  • [6] Design of a Novel Hollow-Fiber Membrane Contactor for Carbon Dioxide Absorption
    Gong, Han
    Shen, Jinsheng
    ENVIRONMENTAL BIOTECHNOLOGY AND MATERIALS ENGINEERING (2013), 2013, 777 : 33 - 37
  • [7] Heat and mass transfer in a hollow fiber membrane contactor for sweeping gas membrane distillation
    Huang, Si-Min
    Chen, Yang-Hui
    Yuan, Wu-Zhi
    Zhao, Shuaifei
    Hong, Yuxiang
    Ye, Wei-Biao
    Yang, Minlin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2019, 220 : 334 - 344
  • [8] Theoretical and Experimental Studies on Acetylene Absorption in a Polytetrafluoroethylene Hollow-Fiber Membrane Contactor
    Wang, Xiaoxu
    Gao, Jia
    Zhang, Jianshu
    Zhang, Xiaopeng
    Guo, Ruili
    CHEMICAL ENGINEERING & TECHNOLOGY, 2015, 38 (02) : 215 - 222
  • [9] Mass Transfer Simulation of Caffeine Extraction by Subcritical CO2 in a Hollow-Fiber Membrane Contactor
    Shirazian, S.
    Ashrafizadeh, S. N.
    SOLVENT EXTRACTION AND ION EXCHANGE, 2010, 28 (02) : 267 - 286
  • [10] Analysis of mass transfer in hollow-fiber membranes
    Nagy, E
    Hadik, P
    DESALINATION, 2002, 145 (1-3) : 147 - 152