Effects of Intra-aortic Balloon Pump Counterpulsation on Left Ventricular Mechanoenergetics in a Porcine Model of Acute Ischemic Heart Failure

被引:15
作者
Malliaras, Konstantinos [1 ]
Charitos, Efstratios [1 ]
Diakos, Nikolaos [1 ]
Pozios, Iraklis [1 ]
Papalois, Apostolos [2 ]
Terrovitis, John [1 ]
Nanas, John [1 ]
机构
[1] Univ Athens, Sch Med, Laiko Hosp, Dept Cardiol 3, GR-11527 Athens, Greece
[2] Elpen Pharmaceut, Expt Res Ctr, Athens, Greece
关键词
Intra-aortic balloon pump; Counterpulsation; Mechanical circulatory support; Acute heart failure; Pressure-volume loops; CORONARY PERFUSION-PRESSURE; CARDIOGENIC-SHOCK; ISOVOLUMIC RELAXATION; MYOCARDIAL-INFARCTION; DIASTOLIC FUNCTION; CARDIAC-FUNCTION; LOAD; VOLUME; PERFORMANCE; ASSISTANCE;
D O I
10.1007/s12265-014-9600-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated the effects of intra-aortic balloon pump (IABP) counterpulsation on left ventricular (LV) contractility, relaxation, and energy consumption and probed the underlying physiologic mechanisms in 12 farm pigs, using an ischemia-reperfusion model of acute heart failure. During both ischemia and reperfusion, IABP support unloaded the LV, decreased LV energy consumption (pressure-volume area, stroke work), and concurrently improved LV mechanical performance (ejection fraction, stroke volume, cardiac output). During reperfusion exclusively, IABP also improved LV relaxation (tau) and contractility (Emax, PRSW). The beneficial effects of IABP support on LV relaxation and contractility correlated with IABP-induced augmentation of coronary blood flow. In conclusion, we find that during both ischemia and reperfusion, IABP support optimizes LV energetic performance (decreases energy consumption and concurrently improves mechanical performance) by LV unloading. During reperfusion exclusively, IABP support also improves LV contractility and active relaxation, possibly due to a synergistic effect of unloading and augmentation of coronary blood flow.
引用
收藏
页码:810 / 820
页数:11
相关论文
共 37 条
  • [1] Use of intraaortic balloon counterpulsation in patients presenting with cardiogenic shock: Observations from the GUSTO-I study
    Anderson, RD
    Ohman, EM
    Holmes, DR
    Col, J
    Stebbins, AL
    Bates, ER
    Stomel, RJ
    Granger, CB
    Topol, EJ
    Califf, RM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) : 708 - 715
  • [2] EFFECT OF CIRCULATORY ASSIST DEVICES ON STUNNED MYOCARDIUM
    BAVARIA, JE
    FURUKAWA, S
    KREINER, G
    GUPTA, KB
    STREICHER, J
    EDMUNDS, LH
    [J]. ANNALS OF THORACIC SURGERY, 1990, 49 (01) : 123 - 128
  • [3] Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers
    Burkhoff, D
    Mirsky, I
    Suga, H
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2005, 289 (02): : H501 - H512
  • [4] Ambulatory intraaortic balloon pump use as bridge to heart transplant
    Cochran, RP
    Starkey, TD
    Panos, AL
    Kunzelman, KS
    [J]. ANNALS OF THORACIC SURGERY, 2002, 74 (03) : 746 - 751
  • [5] EFFECTS OF GRADED REDUCTIONS IN CORONARY PERFUSION-PRESSURE ON THE DIASTOLIC PRESSURE-SEGMENT LENGTH RELATION AND THE RATE OF ISOVOLUMIC RELAXATION IN THE RESTING CONSCIOUS DOG
    FARHI, ER
    CANTY, JM
    KLOCKE, FJ
    [J]. CIRCULATION, 1989, 80 (05) : 1458 - 1468
  • [6] CORONARY PHYSIOLOGY
    FEIGL, EO
    [J]. PHYSIOLOGICAL REVIEWS, 1983, 63 (01) : 1 - 205
  • [7] Intra-aortic balloon counterpulsation as a bridge to heart transplantation does not impair long-term survival
    Gjesdal, Ola
    Gude, Einar
    Arora, Satish
    Leivestad, Torbjorn
    Andreassen, Arne K.
    Gullestad, Lars
    Aaberge, Lars
    Brunvand, Harald
    Edvardsen, Thor
    Geiran, Odd R.
    Simonsen, Svein
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2009, 11 (07) : 709 - 714
  • [8] LINEARITY OF THE FRANK-STARLING RELATIONSHIP IN THE INTACT HEART - THE CONCEPT OF PRELOAD RECRUITABLE STROKE WORK
    GLOWER, DD
    SPRATT, JA
    SNOW, ND
    KABAS, JS
    DAVIS, JW
    OLSEN, CO
    TYSON, GS
    SABISTON, DC
    RANKIN, JS
    [J]. CIRCULATION, 1985, 71 (05) : 994 - 1009
  • [10] Chronic extra-aortic balloon counterpulsation: First-in-human pilot study in end-stage heart failure
    Hayward, Christopher S.
    Peters, William S.
    Merry, Alan F.
    Ruygrok, Peter N.
    Jansz, Paul
    O'Driscoll, Gerry
    Larbalestier, Robert I.
    Smith, Julian A.
    Ho, Betty
    Legget, Malcolm E.
    Milsom, F. Paget
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (12) : 1427 - 1432