A Non-Invasive Continuous Blood Pressure Estimation Approach Based on Machine Learning

被引:67
作者
Chen, Shuo [1 ]
Ji, Zhong [1 ,2 ]
Wu, Haiyan [1 ]
Xu, Yingchao [1 ]
机构
[1] Chongqing Univ, Coll Bioengn, Chongqing 400044, Peoples R China
[2] Chongqing Med Elect Engn Technol Ctr, Chongqing 400044, Peoples R China
关键词
pulse waveform; pulse transit time (PTT); genetic algorithm (GA); machine learning; mean influence value (MIV); ACCURACY;
D O I
10.3390/s19112585
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Considering the existing issues of traditional blood pressure (BP) measurement methods and non-invasive continuous BP measurement techniques, this study aims to establish the systolic BP and diastolic BP estimation models based on machine learning using pulse transit time and characteristics of pulse waveform. In the process of model construction, the mean impact value method was introduced to investigate the impact of each feature on the models and the genetic algorithm was introduced to implement parameter optimization. The experimental results showed that the proposed models could effectively describe the nonlinear relationship between the features and BP and had higher accuracy than the traditional methods with the error of 3.27 +/- 5.52 mmHg for systolic BP and 1.16 +/- 1.97 mmHg for diastolic BP. Moreover, the estimation errors met the requirements of the Advancement of Medical Instrumentation and British Hypertension Society criteria. In conclusion, this study was helpful in promoting the practical application of methods for non-invasive continuous BP estimation models.
引用
收藏
页数:18
相关论文
共 38 条
  • [21] Lu Haijiao, 2011, Zhongguo Yi Liao Qi Xie Za Zhi, V35, P169
  • [22] Luo ZC, 1996, BEIJINGGONG YE XUE X, V22, P71
  • [23] Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
    Payne, RA
    Symeonides, CN
    Webb, DJ
    Maxwell, SRJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (01) : 136 - 141
  • [24] Silva Ikaro, 2014, J Open Res Softw, V2
  • [25] Non-Invasive Blood Pressure Estimation from ECG Using Machine Learning Techniques
    Simjanoska, Monika
    Gjoreski, Martin
    Gams, Matjaz
    Bogdanova, Ana Madevska
    [J]. SENSORS, 2018, 18 (04)
  • [26] Non-invasive continuous blood pressure measurement based on mean impact value method, BP neural network, and genetic algorithm
    Tan, Xia
    Ji, Zhong
    Zhang, Yadan
    [J]. TECHNOLOGY AND HEALTH CARE, 2018, 26 : S87 - S101
  • [27] Target Organ Complications and Cardiovascular Events Associated With Masked Hypertension and White-Coat Hypertension Analysis From the Dallas Heart Study
    Tientcheu, Danielle
    Ayers, Colby
    Das, Sandeep R.
    McGuire, Darren K.
    de Lemos, James A.
    Khera, Amit
    Kaplan, Norman
    Victor, Ronald
    Vongpatanasin, Wanpen
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (20) : 2159 - 2169
  • [28] CONTINUOUS WRIST BLOOD PRESSURE MEASUREMENT WITH ULTRASOUND
    Weber, S.
    Scharfschwerdt, P.
    Seel, T.
    Schauer, T.
    Kertzscher, U.
    Affeld, K.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [29] World Health Statistics, 2021, Monitoring health for the SDGs, sustainable development goals
  • [30] Wu D., 2017, THESIS