Near-infrared monitoring of cerebral oxygenation state during carotid endarterectomy

被引:49
|
作者
Kuroda, S
Houkin, K
Abe, H
Hoshi, Y
Tamura, M
机构
[1] HOKKAIDO UNIV,SCH MED,DEPT NEUROSURG,KITA KU,SAPPORO,HOKKAIDO 060,JAPAN
[2] HOKKAIDO UNIV,ELECT SCI RES INST,BIOPHYS GRP,SAPPORO,HOKKAIDO 060,JAPAN
来源
SURGICAL NEUROLOGY | 1996年 / 45卷 / 05期
关键词
near-infrared spectroscopy; hemoglobin; cytochrome oxidase; oxygen metabolism; cerebral ischemia;
D O I
10.1016/0090-3019(95)00463-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND Recent studies have indicated that near-infrared spectroscopy (NIRS) could continuously and noninvasively observe the changes in cerebral oxygenation state during hypoxia and ischemia, using their optical properties. Its validity and usefulness during cerebrovascular surgery, however, still remain to be clarified. METHODS Using NIPS, we continuously monitored the changes in the concentration of oxyhemoglobin, deoxyhemoglobin, and total hemoglobin ([oxy-Hb], [deoxy-Hb], and [total Hb], respectively) and redox state of cytochrome oxidase (cyt ox) during carotid endarterectomy for 22 patients, and we compared the NIPS responses with those of intraoperative somatosensory evoked potentials (SEP) and regional cerebral blood flow (rCBF). RESULTS In 9 of 22 patients, cross-clamping of the carotid artery caused a continuous decrease in [oxy-Hb] and [total Hb], and an increase in [deoxy-Hb]. Cyt ox was partially reduced during the clamping. These NIRS responses demonstrated the occurrence of severe hypoxia in the ipsilateral cerebral tissue. These patients showed a marked decrease in the N-20 amplitude of SEP and rCBF. In contrast, the other 13 patients did not show a significant decrease in the cerebral oxygenation state, which showed no remarkable changes in either SEP or in rCBF. CONCLUSIONS NIPS could successfully judge the cerebral oxygenation state noninvasively during carotid surgery and was more sensitive to ischemic crisis than other indirect methods.
引用
收藏
页码:450 / 458
页数:9
相关论文
共 50 条
  • [1] MONITORING OF CEREBRAL OXYGENATION USING NEAR-INFRARED SPECTROSCOPY DURING CAROTID ENDARTERECTOMY
    MASON, PF
    BEARD, JD
    BRITISH JOURNAL OF SURGERY, 1994, 81 (12) : 1805 - 1806
  • [2] THE ASSESSMENT OF CEREBRAL OXYGENATION DURING CAROTID ENDARTERECTOMY UTILIZING NEAR-INFRARED SPECTROSCOPY
    MASON, PF
    DYSON, EH
    SELLARS, V
    BEARD, JD
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (05): : 590 - 594
  • [3] MONITORING OF THE CEREBRAL OXYGENATION WITH NEAR-INFRARED SPECTROSCOPY IN COMPARISON TO JUGULAR BULB OXYGEN-SATURATION DURING CAROTID ENDARTERECTOMY
    SCHINDLER, E
    ZICKMANN, B
    MULLER, M
    BOLDT, J
    KROLL, J
    HEMPELMANN, G
    VASA-JOURNAL OF VASCULAR DISEASES, 1995, 24 (02): : 168 - 175
  • [4] Near-infrared monitoring of cerebral oxygenation during angiography
    Okubo, T
    Hayahi, N
    Abe, O
    Masumoto, T
    Yoshioka, N
    Ohtomo, K
    RADIOLOGY, 1998, 209P : 472 - 472
  • [5] Cerebral monitoring during carotid endarterectomy using near-infrared diffuse optical spectroscopies and electroencephalogram
    Shang, Yu
    Cheng, Ran
    Dong, Lixin
    Ryan, Stephen J.
    Saha, Sibu P.
    Yu, Guoqiang
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (10): : 3015 - 3032
  • [6] NEAR-INFRARED MONITORING OF CEREBRAL OXYGENATION IN NEONATES
    COPE, M
    DELPY, DT
    WYATT, JS
    WRAY, S
    REYNOLDS, EOR
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1987, 8 (04): : 394 - 394
  • [7] Cerebral Blood Flow Measurement by Near-Infrared Spectroscopy During Carotid Endarterectomy
    Kato, Shinya
    Yoshitani, Kenji
    Ohnishi, Yoshihiko
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2016, 28 (04) : 291 - 295
  • [8] Cerebral oxygenation monitoring: near-infrared spectroscopy
    Tobias, Joseph D.
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (02) : 235 - 243
  • [9] The contribution of extracranial blood oxygenation on near-infrared spectroscopy during carotid endarterectomy - Reply
    Grubhofer, G
    Labnigg, A
    ANAESTHESIA, 1997, 52 (07) : 706 - 707
  • [10] The use of near-infrared cerebral oximetry in awake carotid endarterectomy
    Carlin, RE
    McGraw, DJ
    Calimlim, JR
    Mascia, MF
    JOURNAL OF CLINICAL ANESTHESIA, 1998, 10 (02) : 109 - 113