共 7 条
Evaluation of Regeneration Processes for Filtering Facepiece Respirators in Terms of the Bacteria Inactivation Efficiency and Influences on Filtration Performance
被引:54
|作者:
He, Weidong
[1
,2
,3
]
Guo, Yinghe
[1
,2
,3
]
Gao, Hanchao
[2
,3
]
Liu, Jingxian
[1
]
Yue, Yang
[2
,3
]
Wang, Jing
[2
,3
]
机构:
[1] Northeastern Univ, Filter Test Ctr, CN-110819 Shenyang, Liaoning, Peoples R China
[2] Swiss Fed Inst Technol, Inst Environm Engn, CH-8093 Zurich, Switzerland
[3] Empa, Lab Adv Analyt Technol, CH-8600 Dubendorf, Switzerland
来源:
关键词:
COVID-19;
nanoparticles;
mask regeneration;
filtration performance;
charge decay;
ESCHERICHIA-COLI;
DISINFECTION;
TEMPERATURE;
MECHANISMS;
VIRUSES;
STEAM;
UV;
STERILIZATION;
BIOAEROSOLS;
ULTRAVIOLET;
D O I:
10.1021/acsnano.0c04782
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
The regeneration of filtering facepiece respirators (FFRs) is of critical importance because of the severe shortage of FFRs during large-scale outbreaks l of respiratory epidemics, such as COVID-19. Comprehensive experiments regarding FFR regeneration were performed in this study with model bacteria to illustrate the decontamination performance of the regeneration processes. The results showed that it is dangerous to use a contaminated FFR without any microbe inactivation treatment because the bacteria can live for more than 8 h. The filtration efficiency and surface electrostatic potential of 75% ethanoltreated FFRs were significantly reduced, and a most penetrating particle size of 200 nm was observed. Steam and microwave irradiation (MINI) showed promising decontamination performances, achieving 100% inactivation in 90 and 30 min, respectively. The filtration efficiencies l of steam-treated FFRs lfor 50 and 100 nm particles decreased from 98.86% and 99.51% to 97.58% and 98.79%, respectively. Ultraviolet lirradiation (UVI) effectively inactivated the surface bacteria with a short treatment of 5 min and did not affect the filtration performance. However, the UV dose reaching different layers of the FFP2 mask sample gradually decreased from the outermost layer to the innermost layer, while the model bacteria on the second and third layers could not be killed completely. UVI+MWI and steam were recommended to effectively decontaminate the used respirators and still maintain the respirators' filtration efficiency. The present work provides a comprehensive evaluation for FFR regeneration in terms of the filtration efficiencies for 50-500 nm particles, the electrostatic properties, mechanical properties, and decontamination effects.
引用
收藏
页码:13161 / 13171
页数:11
相关论文