共 28 条
Circulating Current Analysis and Suppression for Configured Three-Limb Inductors in Paralleled Three-Level T-Type Converters With Space-Vector Modulation
被引:41
作者:
Li, Yang
[1
]
Yang, Xu
[1
]
Chen, Wenjie
[1
]
机构:
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Parallel;
space-vector pulse-width modulation (SVPWM);
three-level T-type converters (3LT(2)Cs);
three-phase three-limb inductors (3P3LIs);
zero-sequence circulating currents (ZSCCs);
POINT VOLTAGE OSCILLATIONS;
PWM;
INVERTERS;
D O I:
10.1109/TPEL.2016.2582687
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
In high-power applications, paralleling three-level T-type converters (3LT(2)Cs) with common ac and dc sides represents a modular solution for overcoming limitations of active switches. However, when independent space-vector pulse-width modulation (SVPWM) is employed, zero-sequence circulating currents (ZSCCs) will emerge. Especially, the use of three-phase three-limb inductors (3P3LIs) without additional passive components to reduce cost and improve density of overall parallel system, will worsen ZSCC problem. In this paper, detailed analysis of ZSCCs generated by SVPWM based on a derived average model taking into account magnetic circuit characteristics of 3P3LIs is proposed. Furthermore, four inter-related methods are sequentially proposed: 1) synchronizing sector numbers based on modified vector diagram partition for eliminating periodical ZSCC jumps caused by asynchronous change of starting small vector; 2) feeding forward grid voltages for eliminating starting current jumps due to computation delay; 3) connecting neural points to eliminating constant dc ZSCC caused by neural-point voltage deviation; and 4) adjusting relative duration of negative and positive small vectors in pairs to suppress remaining low-frequency ZSCCs. Consequently, 3LT(2)Cs operated in parallel can separately regulate output powers with a good circulating current suppression performance. The validity of theoretical analysis and proposed methods is verified by experiment with three-parallel 175-kw 3LT(2)Cs.
引用
收藏
页码:3338 / 3354
页数:17
相关论文